Literature DB >> 15801051

Basics of cardiac MDCT: techniques and contrast application.

Bernd J Wintersperger1, Konstantin Nikolaou.   

Abstract

The purpose of this article is to review the basic techniques of cardiac MDCT including the most recent 64-slice scanner generation. Besides the technical developments of different MDCT generations within recent years, the basic principles of ECG-related CT algorithms are discussed. Retrospective ECG-gated data acquisitions are considered as a prerequisite for reliable and reproducible calcium scoring as well as for volumetric assessment of the coronary artery tree. While data acquisition itself is rather straightforward, the optimization of image quality, the knowledge of adequate scan protocols and especially knowledge of possibly arising artefacts is mandatory for a stable high image quality. As data acquisition is becoming faster with the most recent advent of 64-slice MDCT, protocols have to be adapted to this new scanner generation. On the other hand, the improvement in spatial as well as in temporal resolution shows impact on the accuracy and stability of coronary CT angiography. However, the use of dose-reducing technical improvements is strongly recommended.

Entities:  

Mesh:

Year:  2005        PMID: 15801051     DOI: 10.1007/s10406-005-0090-0

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  12 in total

1.  Coronary artery imaging during preoperative CT staging: preliminary experience with 64-slice multidetector CT in 99 consecutive patients.

Authors:  Damien Delhaye; Martine Remy-Jardin; Céline Rozel; Catherine Dusson; Alain Wurtz; Valérie Delannoy-Deken; Alain Duhamel; Jacques Remy
Journal:  Eur Radiol       Date:  2006-10-24       Impact factor: 5.315

2.  Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography: comparison with cine magnetic resonance imaging.

Authors:  Bénédicte Belge; Emmanuel Coche; Agnès Pasquet; Jean-Louis J Vanoverschelde; Bernhard L Gerber
Journal:  Eur Radiol       Date:  2006-03-02       Impact factor: 5.315

3.  Reduction of the total injection volume of contrast material with a short injection duration in 64-detector row CT coronary angiography.

Authors:  F Tatsugami; T Kanamoto; G Nakai; Y Takeda; H Morita; I Morinaga; S Yoshikawa; I Narabayashi
Journal:  Br J Radiol       Date:  2009-06-08       Impact factor: 3.039

4.  Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy.

Authors:  Rihyeon Kim; Eun-Ah Park; Whal Lee; Jin Wook Chung
Journal:  Eur Radiol       Date:  2016-02-23       Impact factor: 5.315

5.  Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries.

Authors:  Joelle M Kefer; Emmanuel Coche; Jean-Louis J Vanoverschelde; Bernhard L Gerber
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

Review 6.  The role of computed tomography in the diagnosis of acute and chronic pulmonary embolism.

Authors:  Halil Doğan; Albert de Roos; Jacob Geleijins; Menno V Huisman; Lucia J M Kroft
Journal:  Diagn Interv Radiol       Date:  2015 Jul-Aug       Impact factor: 2.630

7.  The role of serum levels of microRNA-21 and matrix metalloproteinase-9 in patients with acute coronary syndrome.

Authors:  Faramarz Darabi; Mahmoud Aghaei; Ahmad Movahedian; Ali Pourmoghadas; Nizal Sarrafzadegan
Journal:  Mol Cell Biochem       Date:  2016-09-02       Impact factor: 3.396

8.  Cost effectiveness of coronary angiography and calcium scoring using CT and stress MRI for diagnosis of coronary artery disease.

Authors:  Marc Dewey; Bernd Hamm
Journal:  Eur Radiol       Date:  2006-10-10       Impact factor: 5.315

9.  Association of serum microRNA-21 levels with Visfatin, inflammation, and acute coronary syndromes.

Authors:  Faramarz Darabi; Mahmoud Aghaei; Ahmad Movahedian; Armin Elahifar; Ali Pourmoghadas; Nizal Sarrafzadegan
Journal:  Heart Vessels       Date:  2016-10-26       Impact factor: 2.037

10.  Assessment of right ventricular function with 320-slice volume cardiac CT: comparison with cardiac magnetic resonance imaging.

Authors:  Xiaoyong Huang; Xin Pu; Ruiyu Dou; Xi Guo; Zixu Yan; Zhaoqi Zhang; Meng Li; Hong Jiang; Biao Lu
Journal:  Int J Cardiovasc Imaging       Date:  2012-11-18       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.