Literature DB >> 20946559

Subtraction magnetocardiogram for detecting coronary heart disease.

Akihiko Kandori1, Kuniomi Ogata, Tsuyoshi Miyashita, Hiroshi Takaki, Hideyuki Kanzaki, Syuji Hashimoto, Wataru Shimizu, Shiro Kamakura, Shigeyuki Watanabe, Kazutaka Aonuma.   

Abstract

BACKGROUND: A large-scale magnetocardiogram (MCG) database was produced, and standard MCG waveforms of healthy patients were calculated by using this database. It was clarified that the standard MCG waveforms are formed with the same shape and current distribution in healthy patients. A new subtraction method for detecting abnormal ST-T waveforms in coronary heart disease (CHD) patients by using the standard MCG waveform was developed.
METHODS: We used MCGs of 56 CHD patients (63 ± 3 years old) and 101 age-matched normal control patients (65 ± 5 years old). To construct a subtracted ST-T waveform, we used standard MCG waveforms produced from 464 normal MCGs (male: 268, female: 196). The standard MCG waveforms were subtracted from each subject's measured MCGs, which were shortened or lengthened and normalized to adjust to the data length and magnitude of the standard waveform. We evaluated the maximum amplitude and maximum current-arrow magnitude of the subtracted ST-T waveform.
RESULTS: The maximum magnetic field, maximum magnitude of current arrows, and maximum magnitude of total current vector increased according to the number of coronary artery lesions. The sensitivity and specificity of detecting CHD and normal control patients were 74.6% and 84.1%, respectively.
CONCLUSIONS: The subtraction MCG method can be used to detect CHD with high accuracy, namely, sensitivity of 74.6% and specificity of 84.1% (in the case of maximum amplitude of total current vector). Furthermore, the subtraction MCG magnitude and its current distribution can reflect the expanse of the ischemic lesion area and the progress from ischemia to myocardial infarction. ©2010, Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20946559      PMCID: PMC6932025          DOI: 10.1111/j.1542-474X.2010.00392.x

Source DB:  PubMed          Journal:  Ann Noninvasive Electrocardiol        ISSN: 1082-720X            Impact factor:   1.468


  20 in total

1.  The value of magnetocardiography in the course of coronary intervention.

Authors:  Birgit Hailer; Peter Van Leeuwen; Illja Chaikovsky; Sabine Auth-Eisernitz; Harald Schäfer; Dietrich Grönemeyer
Journal:  Ann Noninvasive Electrocardiol       Date:  2005-04       Impact factor: 1.468

2.  Cancellation of ventricular activity in the ECG: evaluation of novel and existing methods.

Authors:  Mathieu Lemay; Jean-Marc Vesin; Adriaan van Oosterom; Vincent Jacquemet; Lukas Kappenberger
Journal:  IEEE Trans Biomed Eng       Date:  2007-03       Impact factor: 4.538

3.  Repolarization spatial-time current abnormalities in patients with coronary heart disease.

Authors:  Kuniomi Ogata; Akihiko Kandori; Yasushi Watanabe; Akihiro Suzuki; Kimio Tanaka; Yuji Oka; Hiroshi Takaki; Hideaki Kanzaki; Satoshi Nakatani; Kunio Miyatake; Shigeyuki Watanabe; Iwao Yamaguchi; Tsuyoshi Miyashita; Shiro Kamakura
Journal:  Pacing Clin Electrophysiol       Date:  2009-04       Impact factor: 1.976

4.  Noninvasive coronary artery imaging: magnetic resonance angiography and multidetector computed tomography angiography: a scientific statement from the american heart association committee on cardiovascular imaging and intervention of the council on cardiovascular radiology and intervention, and the councils on clinical cardiology and cardiovascular disease in the young.

Authors:  David A Bluemke; Stephan Achenbach; Matthew Budoff; Thomas C Gerber; Bernard Gersh; L David Hillis; W Gregory Hundley; Warren J Manning; Beth Feller Printz; Matthias Stuber; Pamela K Woodard
Journal:  Circulation       Date:  2008-06-27       Impact factor: 29.690

5.  Non-invasive resting magnetocardiographic imaging for the rapid detection of ischemia in subjects presenting with chest pain.

Authors:  Kirsten Tolstrup; Bo E Madsen; Jose A Ruiz; Stephen D Greenwood; Judeen Camacho; Robert J Siegel; H Caroline Gertzen; Jai-Wun Park; Peter A Smars
Journal:  Cardiology       Date:  2006-05-29       Impact factor: 1.869

6.  Differential effects of beta-adrenergic agonists and antagonists in LQT1, LQT2 and LQT3 models of the long QT syndrome.

Authors:  W Shimizu; C Antzelevitch
Journal:  J Am Coll Cardiol       Date:  2000-03-01       Impact factor: 24.094

7.  A method for detecting myocardial abnormality by using a total current-vector calculated from ST-segment deviation of a magnetocardiogram signal.

Authors:  A Kandori; H Kanzaki; K Miyatake; S Hashimoto; S Itoh; N Tanaka; T Miyashita; K Tsukada
Journal:  Med Biol Eng Comput       Date:  2001-01       Impact factor: 2.602

8.  Detection of atrial-flutter and atrial-fibrillation waveforms by fetal magnetocardiogram.

Authors:  A Kandori; T Hosono; T Kanagawa; S Miyashita; Y Chiba; M Murakami; T Miyashita; K Tsukada
Journal:  Med Biol Eng Comput       Date:  2002-03       Impact factor: 2.602

Review 9.  Magnetocardiograms in clinical medicine: unique information on cardiac ischemia, arrhythmias, and fetal diagnosis.

Authors:  Satsuki Yamada; Iwao Yamaguchi
Journal:  Intern Med       Date:  2005-01       Impact factor: 1.271

10.  Multidetector computed tomography coronary artery plaque predictors of stress-induced myocardial ischemia by SPECT.

Authors:  Fay Lin; Leslee J Shaw; Daniel S Berman; Tracy Q Callister; Jonathan W Weinsaft; Franklin J Wong; Massimiliano Szulc; Vishal Tandon; Peter M Okin; Richard B Devereux; James K Min
Journal:  Atherosclerosis       Date:  2007-08-27       Impact factor: 5.162

View more
  4 in total

Review 1.  The role of noninvasive cardiovascular testing, applied clinical nutrition and nutritional supplements in the prevention and treatment of coronary heart disease.

Authors:  Mark Houston
Journal:  Ther Adv Cardiovasc Dis       Date:  2018-01-10

2.  Unshielded magnetocardiography: Repeatability and reproducibility of automatically estimated ventricular repolarization parameters in 204 healthy subjects.

Authors:  Anna Rita Sorbo; Gianmarco Lombardi; Lara La Brocca; Gianluigi Guida; Riccardo Fenici; Donatella Brisinda
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-12-20       Impact factor: 1.468

Review 3.  Magnetocardiography for the diagnosis of coronary artery disease: a systematic review and meta-analysis.

Authors:  Rajender Agarwal; Abhimanyu Saini; Tareq Alyousef; Craig A Umscheid
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-08-13       Impact factor: 1.468

4.  Comparison of Electric- and Magnetic-Cardiograms Produced by Myocardial Ischemia in Models of the Human Ventricle and Torso.

Authors:  Erick A Perez Alday; Haibo Ni; Chen Zhang; Michael A Colman; Zizhao Gan; Henggui Zhang
Journal:  PLoS One       Date:  2016-08-24       Impact factor: 3.240