Literature DB >> 15776245

Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography.

Emmanuel Coche1, Alain Vlassenbroek, Véronique Roelants, William D'Hoore, Franck Verschuren, Louis Goncette, Baudouin Maldague.   

Abstract

This study aimed to assess the feasibility of cardiac global function evaluation during a whole-chest multi-slice CT (MSCT) acquisition in patients referred for suspicion of pulmonary embolism (PE), and to compare the results with planar equilibrium radionuclide ventriculography (ERNA). Ten consecutive haemodynamically stable patients (six female, four male; mean age 69.7 years; heart rate 65-99 bpm) with suspicion of PE underwent an MSCT and ERNA within a 6 h period. CT acquisition was performed after contrast medium injection by using 16x1.5 mm collimation and retrospective ECG gating. Left ventricular (LVEF) and right ventricular (RVEF) ejection fractions were calculated using dedicated three-dimensional software. Relationships between measurements obtained with MSCT and ERNA were assessed using linear regression analysis and reliability of MSCT was assessed with intra-class correlation coefficient. Bland-Altman analysis was performed to calculate limits of agreement between MSCT and ERNA. MSCT was performed successfully in ten patients with a mean acquisition time of 16.5+/-2.8 s. Functional cardiac evaluation was possible on CT for all patients except for one due to poor opacification of right ventricle. Linear regression analysis showed a good correlation between MSCT and ERNA for the LVEF (R=0.91) and the RVEF (R=0.89) measurements. Intra-class correlation was superior for LVEF (0.92) than for the RVEF (0.68). Bland-Altman plots demonstrated that MSCT substantially overestimated the ERNA RVEF. Morphological CT data demonstrated PE in four of ten of patients and alternative diagnoses in five of ten patients. Our study reveals that MSCT with retrospective ECG gating may provide in one modality a morphological and a functional cardiopulmonary evaluation. Comparison with ERNA demonstrated a good correlation for both ventricular ejection fractions.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15776245     DOI: 10.1007/s00330-004-2582-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  39 in total

1.  Right ventricular function in patients after acute myocardial infarction assessed with phase contrast MR velocity mapping encoded in three directions.

Authors:  H W Kayser; R J van der Geest; E E van der Wall; C Duchateau; A de Roos
Journal:  J Magn Reson Imaging       Date:  2000-05       Impact factor: 4.813

2.  Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction.

Authors:  Emmanuel Coche; Sebastien Pawlak; Stéphane Dechambre; Baudouin Maldague
Journal:  Eur Radiol       Date:  2002-11-01       Impact factor: 5.315

3.  Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience.

Authors:  Kai Uwe Juergens; Matthias Grude; David Maintz; Eva Maria Fallenberg; Thomas Wichter; Walter Heindel; Roman Fischbach
Journal:  Radiology       Date:  2003-12-10       Impact factor: 11.105

4.  Diagnosis of acute pulmonary embolism in outpatients: comparison of thin-collimation multi-detector row spiral CT and planar ventilation-perfusion scintigraphy.

Authors:  Emmanuel Coche; Franck Verschuren; André Keyeux; Pierre Goffette; Louis Goncette; Philippe Hainaut; Frank Hammer; Edith Lavenne; Francis Zech; Philippe Meert; Marc S Reynaert
Journal:  Radiology       Date:  2003-12       Impact factor: 11.105

5.  Right ventricular enlargement on chest computed tomography: prognostic role in acute pulmonary embolism.

Authors:  Rene Quiroz; Nils Kucher; U Joseph Schoepf; Florian Kipfmueller; Scott D Solomon; Philip Costello; Samuel Z Goldhaber
Journal:  Circulation       Date:  2004-05-17       Impact factor: 29.690

6.  Pulmonary embolism for cardiologists.

Authors:  S Z Goldhaber
Journal:  J Am Coll Cardiol       Date:  1997-11-01       Impact factor: 24.094

7.  Significance of gated equilibrium radionuclide ventriculography in quantification and follow up of valvular regurgitation.

Authors:  E Voth; R Sciagrà; H Schicha; U Tebbe; V Kählert; D Emrich
Journal:  Eur J Nucl Med       Date:  1988

8.  A new technique for assessing right ventricular ejection fraction using rapid multiple-gated equilibrium cardiac blood pool scintigraphy. Description, validation and findings in chronic coronary artery disease.

Authors:  J Maddahi; D S Berman; D T Matsuoka; A D Waxman; K E Stankus; J S Forrester; H J Swan
Journal:  Circulation       Date:  1979-09       Impact factor: 29.690

Review 9.  Pulmonary embolus imaging with multislice CT.

Authors:  Martine Remy-Jardin; Ioana Mastora; Jacques Remy
Journal:  Radiol Clin North Am       Date:  2003-05       Impact factor: 2.303

10.  Use of equilibrium (gated) radionuclide ventriculography to quantitate left ventricular output in patients with and without left-sided valvular regurgitation.

Authors:  M A Konstam; J Wynne; B L Holman; E J Brown; J M Neill; J Kozlowski
Journal:  Circulation       Date:  1981-09       Impact factor: 29.690

View more
  11 in total

1.  Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography.

Authors:  Martin Heuschmid; Julia K Rothfuss; Stephen Schroeder; Michael Fenchel; Norbert Stauder; Christof Burgstahler; Andreas Franow; Ronald S Kuzo; Axel Kuettner; Stephan Miller; Claus D Claussen; Andreas F Kopp
Journal:  Eur Radiol       Date:  2005-10-08       Impact factor: 5.315

2.  Integrated cardio-thoracic imaging with ECG-Gated 64-slice multidetector-row CT: initial findings in 133 patients.

Authors:  Randa Salem; Martine Remy-Jardin; Damien Delhaye; Chadi Khalil; Antoine Teisseire; Valérie Delannoy-Deken; Alain Duhamel; Jacques Remy
Journal:  Eur Radiol       Date:  2006-04-25       Impact factor: 5.315

3.  Measurement of cardiac ventricular volumes using multidetector row computed tomography: comparison of two- and three-dimensional methods.

Authors:  M Montaudon; E Laffon; P Berger; O Corneloup; V Latrabe; F Laurent
Journal:  Eur Radiol       Date:  2006-04-12       Impact factor: 5.315

4.  Mutidetector-row CT and quantitative gated SPECT for the assessment of left ventricular function in small hearts: the cardiac physical phantom study using a combined SPECT/CT system.

Authors:  Daisuke Utsunomiya; Seiji Tomiguchi; Kazuo Awai; Shinya Shiraishi; Takeshi Nakaura; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2006-02-03       Impact factor: 5.315

5.  Coronary artery imaging during preoperative CT staging: preliminary experience with 64-slice multidetector CT in 99 consecutive patients.

Authors:  Damien Delhaye; Martine Remy-Jardin; Céline Rozel; Catherine Dusson; Alain Wurtz; Valérie Delannoy-Deken; Alain Duhamel; Jacques Remy
Journal:  Eur Radiol       Date:  2006-10-24       Impact factor: 5.315

6.  Accuracy and variability of right ventricular volumes and mass assessed by dual-source computed tomography: influence of slice orientation in comparison to magnetic resonance imaging.

Authors:  Christoph J Jensen; Alexander Wolf; Holger C Eberle; Michael Forsting; Kai Nassenstein; Thomas C Lauenstein; Georg V Sabin; Oliver Bruder; Thomas Schlosser
Journal:  Eur Radiol       Date:  2011-07-27       Impact factor: 5.315

7.  Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients.

Authors:  A G d'Agostino; M Remy-Jardin; C Khalil; V Delannoy-Deken; T Flohr; A Duhamel; J Remy
Journal:  Eur Radiol       Date:  2006-04-12       Impact factor: 5.315

Review 8.  Is the lung scan alive and well? Facts and controversies in defining the role of lung scintigraphy for the diagnosis of pulmonary embolism in the era of MDCT.

Authors:  John H Reid; Emmanuel E Coche; Tomio Inoue; Edmund E Kim; Maurizio Dondi; Naoyuki Watanabe; Giuliano Mariani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-01-27       Impact factor: 9.236

Review 9.  [Multidetector-row CT in severe pulmonary embolism: radiologists' help in risk stratification].

Authors:  C Engelke; K Marten
Journal:  Radiologe       Date:  2007-08       Impact factor: 0.635

10.  Cardiothoracic CT: one-stop-shop procedure? Impact on the management of acute pulmonary embolism.

Authors:  Pauline J Abrahams-van Doorn; Ieneke J C Hartmann
Journal:  Insights Imaging       Date:  2011-08-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.