Literature DB >> 16937136

Accelerated time-resolved 3D contrast-enhanced MR angiography at 3T: clinical experience in 31 patients.

Alex Frydrychowicz1, Thorsten A Bley, Jan T Winterer, Andreas Harloff, Mathias Langer, Jürgen Hennig, Michael Markl.   

Abstract

PURPOSE: To evaluate whether time-resolved 3D MR-angiography at 3T with a net acceleration factor of eight is applicable in clinical routine and to evaluate whether good image quality and a low artifact level can be achieved with a temporal update rate that allows for additional information on pathologies.
MATERIALS AND METHODS: Thirty-one consecutive patients underwent time-resolved 3D contrast-enhanced MR-angiography on a 3T system. Imaging consisted of accelerated 3D gradient echo sequences combining parallel imaging with an acceleration factor of four, partial Fourier acquisition along phase and slice encoding direction, and twofold temporal acceleration using view sharing. Data volumes representing the arterial and venous contrast phases were independently evaluated by two experienced radiologists by grading of image quality and artifact level on a 0-3 scale.
RESULTS: Time-resolved MR-angiography was successfully performed in all subjects without the need for contrast agent bolus timing. Excellent arterial (average score = 2.65 +/- 0.32) and good venous (average score = 2.56 +/- 0.28) diagnostic image quality and little image degrading due to artifacts (average score = 2.20 +/- 0.16) were confirmed by both independent readers (agreement in 65.2% of all evaluations). In 14 patients vascular pathologies were identified in the arterial phases. In eight examinations temporal resolution and depiction of contrast agent dynamics provided additional information about pathology. DISCUSSION: Without the necessity for additional bolus timing, time-resolved 3D contrast-enhanced MR-angiography with imaging acceleration along both the spatial encoding direction and temporal domain revealed excellent diagnostic image quality in neurovascular and thoracic imaging. Despite the limited spatial resolution as compared to high-resolution imaging of the carotid artery bifurcation, the results demonstrate the applicability of contrast-enhanced MR-angiography in thoracic and abdominal MRA as well as cervical imaging with a temporal update rate allowing for additional information on pathologies. Future studies may include an evaluation of optimal trade-offs between spatial and temporal resolution, different acceleration factors and a comparison to the gold-standard for accuracy.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16937136     DOI: 10.1007/s10334-006-0046-y

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  29 in total

1.  High-resolution pulmonary arterio- and venography using multiple-bolus multiphase 3D-Gd-mRA.

Authors:  S O Schoenberg; M Bock; F Floemer; A Grau; D M Williams; G Laub; M V Knopp
Journal:  J Magn Reson Imaging       Date:  1999-09       Impact factor: 4.813

2.  Time-resolved contrast-enhanced pulmonary MR angiography using sensitivity encoding (SENSE).

Authors:  Yoshiharu Ohno; Hideaki Kawamitsu; Takanori Higashino; Daisuke Takenaka; Hirokazu Watanabe; Marc van Cauteren; Masahiko Fujii; Hiroto Hatabu; Kazuro Sugimura
Journal:  J Magn Reson Imaging       Date:  2003-03       Impact factor: 4.813

3.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

4.  Aortoiliac and lower extremity arteries: comparison of three-dimensional dynamic contrast-enhanced subtraction MR angiography and conventional angiography.

Authors:  E Sueyoshi; I Sakamoto; Y Matsuoka; Y Ogawa; H Hayashi; R Hashmi; K Hayashi
Journal:  Radiology       Date:  1999-03       Impact factor: 11.105

Review 5.  Parallel imaging at high field strength: synergies and joint potential.

Authors:  Klaas P Pruessmann
Journal:  Top Magn Reson Imaging       Date:  2004-08

6.  In vitro validation of phase-contrast flow measurements at 3 T in comparison to 1.5 T: precision, accuracy, and signal-to-noise ratios.

Authors:  Joachim Lotz; Rolf Döker; Ralph Noeske; Meike Schüttert; Roland Felix; Michael Galanski; Matthias Gutberlet; Gerd Peter Meyer
Journal:  J Magn Reson Imaging       Date:  2005-05       Impact factor: 4.813

7.  Time-resolved echo-shared parallel MRA of the lung: observer preference study of image quality in comparison with non-echo-shared sequences.

Authors:  C Fink; M Puderbach; S Ley; J Zaporozhan; C Plathow; H-U Kauczor
Journal:  Eur Radiol       Date:  2005-06-30       Impact factor: 5.315

8.  Peripheral vascular MR angiography: the time has come.

Authors:  M R Prince
Journal:  Radiology       Date:  1998-03       Impact factor: 11.105

9.  Whole-body MR angiography using a novel 32-receiving-channel MR system with surface coil technology: first clinical experience.

Authors:  Michael Fenchel; Martin Requardt; Katrin Tomaschko; Ulrich Kramer; Norbert I Stauder; Thomas Naegele; Heinz-Peter Schlemmer; Claus D Claussen; Stephan Miller
Journal:  J Magn Reson Imaging       Date:  2005-05       Impact factor: 4.813

10.  Rapid magnetic resonance angiography for detection of atherosclerosis.

Authors:  S G Ruehm; M Goyen; J Barkhausen; K Kröger; S Bosk; M E Ladd; J F Debatin
Journal:  Lancet       Date:  2001-04-07       Impact factor: 79.321

View more
  8 in total

1.  Quality-evaluation scheme for cerebral time-resolved 3D contrast-enhanced MR angiography techniques.

Authors:  H Raoult; J-C Ferré; X Morandi; B Carsin-Nicol; M Carsin; M Cuggia; M Law; J-Y Gauvrit
Journal:  AJNR Am J Neuroradiol       Date:  2010-05-06       Impact factor: 3.825

2.  Bilateral contrast-enhanced MR angiography of the hand: diagnostic image quality of accelerated MRI using echo sharing with interleaved stochastic trajectories (TWIST).

Authors:  Jan Thorsten Winterer; P Blanke; A Schaefer; G Pache; M Langer; M Markl
Journal:  Eur Radiol       Date:  2010-11-18       Impact factor: 5.315

Review 3.  [Diagnosing stroke aetiologies. Morphologic and functional analysis of the aorta and carotid arteries by MRI].

Authors:  A Harloff; M Markl; A Frydrychowicz; J Hennig; C Weiller
Journal:  Nervenarzt       Date:  2009-08       Impact factor: 1.214

4.  3D time-resolved MR angiography (MRA) of the carotid arteries with time-resolved imaging with stochastic trajectories: comparison with 3D contrast-enhanced Bolus-Chase MRA and 3D time-of-flight MRA.

Authors:  R P Lim; M Shapiro; E Y Wang; M Law; J S Babb; L E Rueff; J S Jacob; S Kim; R H Carson; T P Mulholland; G Laub; E M Hecht
Journal:  AJNR Am J Neuroradiol       Date:  2008-09-03       Impact factor: 3.825

5.  Max CAPR: high-resolution 3D contrast-enhanced MR angiography with acquisition times under 5 seconds.

Authors:  Clifton R Haider; Eric A Borisch; James F Glockner; Petrice M Mostardi; Phillip J Rossman; Phillip M Young; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

6.  Optimal k-space sampling for dynamic contrast-enhanced MRI with an application to MR renography.

Authors:  Ting Song; Andrew F Laine; Qun Chen; Henry Rusinek; Louisa Bokacheva; Ruth P Lim; Gerhard Laub; Randall Kroeker; Vivian S Lee
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

7.  3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain.

Authors:  Clifton R Haider; Houchun Harry Hu; Norbert G Campeau; John Huston; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

8.  A comparison of 4D time-resolved MRA with keyhole and 3D time-of-flight MRA at 3.0 T for the evaluation of cerebral aneurysms.

Authors:  Qian Wu; Ming-Hua Li
Journal:  BMC Neurol       Date:  2012-07-06       Impact factor: 2.474

  8 in total