Literature DB >> 20715291

Max CAPR: high-resolution 3D contrast-enhanced MR angiography with acquisition times under 5 seconds.

Clifton R Haider1, Eric A Borisch, James F Glockner, Petrice M Mostardi, Phillip J Rossman, Phillip M Young, Stephen J Riederer.   

Abstract

High temporal and spatial resolution is desired in imaging of vascular abnormalities having short arterial-to-venous transit times. Methods that exploit temporal correlation to reduce the observed frame time demonstrate temporal blurring, obfuscating bolus dynamics. Previously, a Cartesian acquisition with projection reconstruction-like (CAPR) sampling method has been demonstrated for three-dimensional contrast-enhanced angiographic imaging of the lower legs using two-dimensional sensitivity-encoding acceleration and partial Fourier acceleration, providing 1mm isotropic resolution of the calves, with 4.9-sec frame time and 17.6-sec temporal footprint. In this work, the CAPR acquisition is further undersampled to provide a net acceleration approaching 40 by eliminating all view sharing. The tradeoff of frame time and temporal footprint in view sharing is presented and characterized in phantom experiments. It is shown that the resultant 4.9-sec acquisition time, three-dimensional images sets have sufficient spatial and temporal resolution to clearly portray arterial and venous phases of contrast passage. It is further hypothesized that these short temporal footprint sequences provide diagnostic quality images. This is tested and shown in a series of nine contrast-enhanced MR angiography patient studies performed with the new method.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20715291      PMCID: PMC3086564          DOI: 10.1002/mrm.22434

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  50 in total

1.  Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy.

Authors:  M A Bernstein; S B Fain; S J Riederer
Journal:  J Magn Reson Imaging       Date:  2001-09       Impact factor: 4.813

2.  Thorax: low-dose contrast-enhanced three-dimensional MR angiography with subsecond temporal resolution--initial results.

Authors:  J Paul Finn; Visveshwar Baskaran; James C Carr; Richard M McCarthy; F Scott Pereles; Randall Kroeker; Gerhard A Laub
Journal:  Radiology       Date:  2002-09       Impact factor: 11.105

3.  k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations.

Authors:  Jeffrey Tsao; Peter Boesiger; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

4.  High-resolution multistation peripheral MR angiography using undersampled projection reconstruction imaging.

Authors:  J Du; F R Korosec; F J Thornton; T M Grist; C A Mistretta
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

Review 5.  Parallel imaging in MR angiography.

Authors:  Gregory J Wilson; Romhild M Hoogeveen; Winfried A Willinek; Raja Muthupillai; Jeffrey H Maki
Journal:  Top Magn Reson Imaging       Date:  2004-06

6.  Venous compression at high-spatial-resolution three-dimensional MR angiography of peripheral arteries.

Authors:  Florian M Vogt; Waleed Ajaj; Peter Hunold; Christoph U Herborn; Harald H Quick; Jörg F Debatin; Stefan G Ruehm
Journal:  Radiology       Date:  2004-10-14       Impact factor: 11.105

7.  Accelerated time-resolved 3D contrast-enhanced MR angiography at 3T: clinical experience in 31 patients.

Authors:  Alex Frydrychowicz; Thorsten A Bley; Jan T Winterer; Andreas Harloff; Mathias Langer; Jürgen Hennig; Michael Markl
Journal:  MAGMA       Date:  2006-08-26       Impact factor: 2.310

Review 8.  3D contrast-enhanced MR angiography.

Authors:  Honglei Zhang; Jeffrey H Maki; Martin R Prince
Journal:  J Magn Reson Imaging       Date:  2007-01       Impact factor: 4.813

9.  Peripheral vasculature: high-temporal- and high-spatial-resolution three-dimensional contrast-enhanced MR angiography.

Authors:  Clifton R Haider; James F Glockner; Anthony W Stanson; Stephen J Riederer
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

10.  Dynamic gadolinium-enhanced three-dimensional abdominal MR arteriography.

Authors:  M R Prince; E K Yucel; J A Kaufman; D C Harrison; S C Geller
Journal:  J Magn Reson Imaging       Date:  1993 Nov-Dec       Impact factor: 4.813

View more
  10 in total

1.  Noncontrast-enhanced three-dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition.

Authors:  Huimin Wu; Walter F Block; Patrick A Turski; Charles A Mistretta; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2012-04-24       Impact factor: 4.668

Review 2.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

3.  Prospective comparison of cartesian acquisition with projection-like reconstruction magnetic resonance angiography with computed tomography angiography for evaluation of below-the-knee runoff.

Authors:  Phillip M Young; Petrice M Mostardi; James F Glockner; Terri R Vrtiska; Thanila Macedo; Clifton R Haider; Stephen J Riederer
Journal:  J Vasc Interv Radiol       Date:  2013-03       Impact factor: 3.464

4.  Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Authors:  Stephen J Riederer; Clifton R Haider; Eric A Borisch; Paul T Weavers; Phillip M Young
Journal:  J Magn Reson Imaging       Date:  2015-06-01       Impact factor: 4.813

5.  Rapid time-resolved magnetic resonance angiography via a multiecho radial trajectory and GraDeS reconstruction.

Authors:  Gregory R Lee; Nicole Seiberlich; Jeffrey L Sunshine; Timothy J Carroll; Mark A Griswold
Journal:  Magn Reson Med       Date:  2012-04-03       Impact factor: 4.668

6.  Time-resolved bolus-chase MR angiography with real-time triggering of table motion.

Authors:  Casey P Johnson; Clifton R Haider; Eric A Borisch; James F Glockner; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

7.  Sparse-CAPR: highly accelerated 4D CE-MRA with parallel imaging and nonconvex compressive sensing.

Authors:  Joshua D Trzasko; Clifton R Haider; Eric A Borisch; Norbert G Campeau; James F Glockner; Stephen J Riederer; Armando Manduca
Journal:  Magn Reson Med       Date:  2011-05-23       Impact factor: 4.668

8.  Buildup of image quality in view-shared time-resolved 3D CE-MRA.

Authors:  Casey P Johnson; Thomas W Polley; James F Glockner; Phillip M Young; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2012-08-30       Impact factor: 4.668

9.  Time resolved contrast enhanced intracranial MRA using a single dose delivered as sequential injections and highly constrained projection reconstruction (HYPR CE).

Authors:  Yijing Wu; Kevin Johnson; Steven R Kecskemeti; Kang Wang; Oliver Wieben; Beverly L Aagaard-Kienitz; Howard Rowley; Frank R Korosec; Charles Mistretta; Patrick Turski
Journal:  Magn Reson Med       Date:  2011-02-17       Impact factor: 4.668

10.  Highly time-resolved 4D MR angiography using golden-angle radial sparse parallel (GRASP) MRI.

Authors:  Adam E Goldman-Yassen; Eytan Raz; Maria J Borja; Duan Chen; Anna Derman; Siddhant Dogra; Kai Tobias Block; Seena Dehkharghani
Journal:  Sci Rep       Date:  2022-09-05       Impact factor: 4.996

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.