Literature DB >> 12594723

Time-resolved contrast-enhanced pulmonary MR angiography using sensitivity encoding (SENSE).

Yoshiharu Ohno1, Hideaki Kawamitsu, Takanori Higashino, Daisuke Takenaka, Hirokazu Watanabe, Marc van Cauteren, Masahiko Fujii, Hiroto Hatabu, Kazuro Sugimura.   

Abstract

PURPOSE: To evaluate the relationship between gadolinium concentration and signal-to-noise ratio (SNR) on sensitivity encoding (SENSE) images, and determine the appropriate bolus injection protocol for visualizing pulmonary circulation.
MATERIALS AND METHODS: Eighteen different gadolinium concentration phantoms (0, 0.01, 0.05, 0.1, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 5.0, 10.0, 20.0, 30.0, 50.0, and 100.0 mmol/L) were analyzed to determine the relationship between gadolinium concentration and SNR on SENSE images in a phantom study. In an in vivo study, 3 mL (protocol A) or 6 mL (protocol B) of Gd-DTPA BMA at 3 mL/second, and 5 mL of Gd-DTPA BMA at 5 mL/second (protocol C) were administered to eight normal volunteers for contrast-enhanced (CE) pulmonary MR angiography (MRA) with SENSE. The peak SNRs of pulmonary parenchyma and the difference in SNR between pulmonary artery (PA) and pulmonary vein (PV) at peak SNR in the PA were statistically evaluated.
RESULTS: For each flip angle at each gadolinium concentration, the SNRs and contrast-to-noise ratios (CNRs) of the SENSE images were significantly lower than those acquired with a nonparallel imaging technique (P < 0.05). The peak SNR of the pulmonary parenchyma, and differences in SNR between the PA and PV at the peak SNR of the PA obtained with a 5-mL/second bolus injection protocol were found to be significantly higher than those obtained with other protocols (P < 0.05).
CONCLUSION: 3D-CE-MRA using SENSE demonstrated linearity between gadolinium concentration and SNR, and resulted in MRA with high spatial and temporal resolution with the aid of a sharp bolus injection protocol. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12594723     DOI: 10.1002/jmri.10261

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  15 in total

Review 1.  Assessment of pulmonary hypertension by CT and MR imaging.

Authors:  Sebastian Ley; Karl-Friedrich Kreitner; Christian Fink; Claus P Heussel; Mathias M Borst; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2004-01-23       Impact factor: 5.315

2.  Improved venous suppression and spatial resolution with SENSE in elliptical centric 3D contrast-enhanced MR angiography.

Authors:  Houchun H Hu; Ananth J Madhuranthakam; David G Kruger; John Huston; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

Review 3.  MR imaging of the pulmonary vasculature--an update.

Authors:  Mark R Pedersen; Mark T Fisher; Edwin J R van Beek
Journal:  Eur Radiol       Date:  2006-01-04       Impact factor: 5.315

4.  Time-resolved echo-shared parallel MRA of the lung: observer preference study of image quality in comparison with non-echo-shared sequences.

Authors:  C Fink; M Puderbach; S Ley; J Zaporozhan; C Plathow; H-U Kauczor
Journal:  Eur Radiol       Date:  2005-06-30       Impact factor: 5.315

5.  Accelerated time-resolved 3D contrast-enhanced MR angiography at 3T: clinical experience in 31 patients.

Authors:  Alex Frydrychowicz; Thorsten A Bley; Jan T Winterer; Andreas Harloff; Mathias Langer; Jürgen Hennig; Michael Markl
Journal:  MAGMA       Date:  2006-08-26       Impact factor: 2.310

6.  Intrinsic signal amplification in the application of 2D SENSE parallel imaging to 3D contrast-enhanced elliptical centric MRA and MRV.

Authors:  Stephen J Riederer; Houchun Harry Hu; David G Kruger; Clifton R Haider; Norbert G Campeau; John Huston
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

7.  Prospective comparison of high- and low-spatial-resolution dynamic MR imaging with sensitivity encoding (SENSE) for hypervascular hepatocellular carcinoma.

Authors:  Masakatsu Tsurusaki; Richard C Semelka; Kensuke Uotani; Koji Sugimoto; Masahiko Fujii; Kazuro Sugimura
Journal:  Eur Radiol       Date:  2008-04-30       Impact factor: 5.315

Review 8.  Chronic thromboembolic pulmonary hypertension - assessment by magnetic resonance imaging.

Authors:  Karl-Friedrich Kreitner; R Peter Kunz; Sebastian Ley; Katja Oberholzer; Daniel Neeb; Klaus K Gast; Claus-Peter Heussel; Balthasar Eberle; Eckhard Mayer; Hans-Ulrich Kauczor; Christoph Düber
Journal:  Eur Radiol       Date:  2006-07-13       Impact factor: 5.315

Review 9.  Contrast-enhanced CT- and MRI-based perfusion assessment for pulmonary diseases: basics and clinical applications.

Authors:  Yoshiharu Ohno; Hisanobu Koyama; Ho Yun Lee; Sachiko Miura; Takeshi Yoshikawa; Kazuro Sugimura
Journal:  Diagn Interv Radiol       Date:  2016 Sep-Oct       Impact factor: 2.630

Review 10.  [MRT of bronchial carcinomas].

Authors:  C Fink; C Plathow; M Klopp; A Schmähl; H-U Kauczor
Journal:  Radiologe       Date:  2004-05       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.