Literature DB >> 16932806

Noise Reduction for Low-Dose Single-Slice Helical CT Sinograms.

Jing Wang1, Tianfang Li, Hongbing Lu, Zhengrong Liang.   

Abstract

Helical computed tomography (HCT) has several advantages over conventional step-and-shoot CT for imaging a relatively large object, especially for dynamic studies. However, HCT may increase X-ray exposure significantly. This work aims to reduce the radiation by lowering X-ray tube current (mA) and filtering low-mA (or dose) sinogram noise of HCT. The noise reduction method is based on three observations on HCT: (1) the axial sampling of HCT projections is nearly continuous as detection system rotates; (2) the noise distribution in sinogram space is nearly a Gaussian after system calibration (including logarithmic transform); and (3) the relationship between the calibrated data mean and variance can be expressed as an exponential functional across the field-of-view. Based on the second and third observations, a penalized weighted least-squares (PWLS) solution is an optimal choice, where the weight is given by the mean-variance relationship. The first observation encourages the use of Karhunen-Loève (KL) transform along the axial direction because of the associated correlation. In the KL domain, the eigenvalue of each principal component and the derived data variance provide the signal-to-noise ratio (SNR) information, resulting in a SNR-adaptive noise reduction. The KL-PWLS noise-reduction method was implemented analytically for efficient restoration of large volume HCT sinograms. Simulation studies showed a noticeable improvement, in terms of image quality and defect detectability, of the proposed noise-reduction method over the Ordered-Subsets Expectation-Maximization reconstruction and the conventional low-pass noise filtering with optimal cutoff frequency and/or other filter parameters.

Year:  2006        PMID: 16932806      PMCID: PMC1553180          DOI: 10.1109/tns.2006.874955

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  13 in total

Review 1.  Fast spatio-temporal image reconstruction for dynamic PET.

Authors:  M N Wernick; E J Infusino; M Milosević
Journal:  IEEE Trans Med Imaging       Date:  1999-03       Impact factor: 10.048

2.  Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography.

Authors:  P Sukovic; N H Clinthorne
Journal:  IEEE Trans Med Imaging       Date:  2000-11       Impact factor: 10.048

3.  Low-dose, volumetric helical CT: image quality, radiation dose, and usefulness for evaluation of bronchiectasis.

Authors:  K J Jung; K S Lee; S Y Kim; T S Kim; Y S Pyeun; J Y Lee
Journal:  Invest Radiol       Date:  2000-09       Impact factor: 6.016

4.  Reduction of noise-induced streak artifacts in X-ray computed tomography through spline-based penalized-likelihood sinogram smoothing.

Authors:  Patrick J La Rivière; David M Billmire
Journal:  IEEE Trans Med Imaging       Date:  2005-01       Impact factor: 10.048

5.  Penalized-likelihood sinogram smoothing for low-dose CT.

Authors:  Patrick J La Rivière
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

6.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

7.  Nonstationary noise characteristics of the helical scan and its impact on image quality and artifacts.

Authors:  J Hsieh
Journal:  Med Phys       Date:  1997-09       Impact factor: 4.071

Review 8.  ROC methodology in radiologic imaging.

Authors:  C E Metz
Journal:  Invest Radiol       Date:  1986-09       Impact factor: 6.016

9.  Evaluation of an efficient compensation method for quantitative fan-beam brain SPECT reconstruction.

Authors:  Tianfang Li; Junhai Wen; Guoping Han; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2005-02       Impact factor: 10.048

10.  Hotelling trace criterion and its correlation with human-observer performance.

Authors:  R D Fiete; H H Barrett; W E Smith; K J Myers
Journal:  J Opt Soc Am A       Date:  1987-05       Impact factor: 2.129

View more
  14 in total

1.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Comparative assessment of energy-mapping approaches in CT-based attenuation correction for PET.

Authors:  Mohammad R Ay; Maryam Shirmohammad; Saeed Sarkar; Arman Rahmim; Habib Zaidi
Journal:  Mol Imaging Biol       Date:  2011-02       Impact factor: 3.488

3.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

4.  Multiscale penalized weighted least-squares sinogram restoration for low-dose X-ray computed tomography.

Authors:  Jing Wang; Zhengrong Liang; Hongbing Lu
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

5.  Noise suppression in scatter correction for cone-beam CT.

Authors:  Lei Zhu; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

6.  An experimental study on the noise properties of x-ray CT sinogram data in Radon space.

Authors:  Jing Wang; Hongbing Lu; Zhengrong Liang; Daria Eremina; Guangxiang Zhang; Su Wang; John Chen; James Manzione
Journal:  Phys Med Biol       Date:  2008-06-03       Impact factor: 3.609

7.  Scatter correction for cone-beam CT in radiation therapy.

Authors:  Lei Zhu; Yaoqin Xie; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

8.  L0 constrained sparse reconstruction for multi-slice helical CT reconstruction.

Authors:  Yining Hu; Lizhe Xie; Limin Luo; Jean Claude Nunes; Christine Toumoulin
Journal:  Phys Med Biol       Date:  2011-02-01       Impact factor: 3.609

9.  Sinogram smoothing techniques for myocardial blood flow estimation from dose-reduced dynamic computed tomography.

Authors:  Dimple Modgil; Adam M Alessio; Michael D Bindschadler; Patrick J La Rivière
Journal:  J Med Imaging (Bellingham)       Date:  2014-11-03

10.  Comparison of radiation doses using weight-based protocol and dose modulation techniques for patients undergoing biphasic abdominal computed tomography examinations.

Authors:  Roshan S Livingstone; Paul M Dinakaran; Rekha S Cherian; Anu Eapen
Journal:  J Med Phys       Date:  2009-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.