Literature DB >> 10982001

Low-dose, volumetric helical CT: image quality, radiation dose, and usefulness for evaluation of bronchiectasis.

K J Jung1, K S Lee, S Y Kim, T S Kim, Y S Pyeun, J Y Lee.   

Abstract

RATIONALE AND
OBJECTIVES: The aim of our study was to assess the image quality, radiation dose, and clinical applicability of low-dose, volumetric helical CT in the evaluation of bronchiectasis.
METHODS: Volumetric helical CT scans (120 kVp, 3-mm collimation, pitch of 2, and reconstruction interval of 2 mm) were obtained through the thorax at four levels of tube current: 150, 100, 70, and 40 mA. There were a total of 12 patients who underwent CT scan either for suspected bronchiectasis or for lung cancer screening, with three patients allocated to each current level. Five radiologists assessed and compared image quality of the helical CT scans obtained at the various exposure levels. Radiation doses of helical CT performed with four different current settings and of high-resolution CT (120 kVp, 170 mA, 1-mm collimation, and 10-mm intervals) were measured. The diagnostic usefulness of the 40-mA helical CT images was compared with that of high-resolution CT by two observers in 52 patients with known or suspected airway diseases.
RESULTS: With helical CT, there was no significant difference in image quality among the four different levels of current (P > 0.05). Radiation doses associated with the 40-, 70-, 100-, and 150-mA helical techniques were 3.21 mGy (range, 3.02-3.57), 4.81 mGy (range, 3.89-5.93), 6.46 mGy (range, 6.01-7.31), and 10.4 mGy (range, 8.93-12.1), respectively, whereas that of high-resolution CT was 2.17 mGy (range, 1.90-2.67). Of 52 patients, 44.5 and 47 patients (the mean of positive interpretations by the five observers) were diagnosed with bronchiectasis at high-resolution and low-dose helical CT, respectively. Of 928 segments, bronchiectasis was seen in 152.5 segments on high-resolution CT and in 193.5 segments on helical CT. The interobserver agreement (k-values) was acceptable for both techniques.
CONCLUSIONS: With acceptable images and similar radiation dose, low-dose volumetric helical CT at 40 mA may offer more information than does high-resolution CT in the evaluation of bronchiectasis.

Entities:  

Mesh:

Year:  2000        PMID: 10982001     DOI: 10.1097/00004424-200009000-00007

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  6 in total

1.  Diagnosis of bronchiectasis with multislice spiral CT: accuracy of 3-mm-thick structured sections.

Authors:  Martine Remy-Jardin; Assia Amara; Philippe Campistron; Ioana Mastora; Valérie Delannoy; Alain Duhamel; Jacques Remy
Journal:  Eur Radiol       Date:  2003-02-11       Impact factor: 5.315

2.  Noise Reduction for Low-Dose Single-Slice Helical CT Sinograms.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Nucl Sci       Date:  2006-06       Impact factor: 1.679

3.  L0 constrained sparse reconstruction for multi-slice helical CT reconstruction.

Authors:  Yining Hu; Lizhe Xie; Limin Luo; Jean Claude Nunes; Christine Toumoulin
Journal:  Phys Med Biol       Date:  2011-02-01       Impact factor: 3.609

4.  A selective kernel-based cycle-consistent generative adversarial network for unpaired low-dose CT denoising.

Authors:  Chaoqun Tan; Mingming Yang; Zhisheng You; Hu Chen; Yi Zhang
Journal:  Precis Clin Med       Date:  2022-05-25

5.  Ultra-low-dose MDCT of the chest: influence on automated lung nodule detection.

Authors:  Ji Young Lee; Myung Jin Chung; Chin A Yi; Kyung Soo Lee
Journal:  Korean J Radiol       Date:  2008 Mar-Apr       Impact factor: 3.500

Review 6.  Suspecting non-cystic fibrosis bronchiectasis: What the busy primary care clinician needs to know.

Authors:  Diego J Maselli; Bravein Amalakuhan; Holly Keyt; Alejandro A Diaz
Journal:  Int J Clin Pract       Date:  2017-02       Impact factor: 2.503

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.