Literature DB >> 9304565

Nonstationary noise characteristics of the helical scan and its impact on image quality and artifacts.

J Hsieh1.   

Abstract

Helical computed tomography has replaced the conventional step-and-shoot CT in many clinical applications. Because of its clinical importance, a number of comparative studies have been performed to evaluate its performance parameters, such as the noise and the slice sensitivity profile. In this paper, the nonstationary noise characteristics of helical images are carefully examined. Their impact on the low contrast detectability and three-dimensional (3-D) image artifacts is assessed. An analytical equation is derived to relate the interactions between various helical reconstruction schemes and the fan-beam filtered backprojection algorithm. We demonstrate that for many popular helical weights, the noise variation within the field of view of the reconstruction is close to a factor of 3. Several approaches to overcome the undesired characteristics are proposed.

Mesh:

Year:  1997        PMID: 9304565     DOI: 10.1118/1.598026

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Backprojection-filtration reconstruction without invoking a spatially varying weighting factor.

Authors:  Dan Xia; Seungryong Cho; Xiaochuan Pan
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

2.  The noise power spectrum in CT with direct fan beam reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

3.  An alternative solution to the nonuniform noise propagation problem in fan-beam FBP image reconstruction.

Authors:  Jing Wang; Hongbing Lu; Tianfang Li; Zhengrong Liang
Journal:  Med Phys       Date:  2005-11       Impact factor: 4.071

4.  Noise Reduction for Low-Dose Single-Slice Helical CT Sinograms.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Nucl Sci       Date:  2006-06       Impact factor: 1.679

Review 5.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

6.  L0 constrained sparse reconstruction for multi-slice helical CT reconstruction.

Authors:  Yining Hu; Lizhe Xie; Limin Luo; Jean Claude Nunes; Christine Toumoulin
Journal:  Phys Med Biol       Date:  2011-02-01       Impact factor: 3.609

7.  Virtual Colonoscopy Screening with Ultra Low-Dose CT and Less-Stressful Bowel Preparation: A computer simulation study.

Authors:  Jing Wang; Su Wang; Lihong Li; Yi Fan; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Nucl Sci       Date:  2008-10       Impact factor: 1.679

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.