Literature DB >> 25642441

Sinogram smoothing techniques for myocardial blood flow estimation from dose-reduced dynamic computed tomography.

Dimple Modgil1, Adam M Alessio2, Michael D Bindschadler2, Patrick J La Rivière1.   

Abstract

Dynamic contrast-enhanced computed tomography (CT) could provide an accurate and widely available technique for myocardial blood flow (MBF) estimation to aid in the diagnosis and treatment of coronary artery disease. However, one of its primary limitations is the radiation dose imparted to the patient. We are exploring techniques to reduce the patient dose by either reducing the tube current or by reducing the number of temporal frames in the dynamic CT sequence. Both of these dose reduction techniques result in noisy data. In order to extract the MBF information from the noisy acquisitions, we have explored several data-domain smoothing techniques. In this work, we investigate two specific smoothing techniques: the sinogram restoration technique in both the spatial and temporal domains and the use of the Karhunen-Loeve (KL) transform to provide temporal smoothing in the sinogram domain. The KL transform smoothing technique has been previously applied to dynamic image sequences in positron emission tomography. We apply a quantitative two-compartment blood flow model to estimate MBF from the time-attenuation curves and determine which smoothing method provides the most accurate MBF estimates in a series of simulations of different dose levels, dynamic contrast-enhanced cardiac CT acquisitions. As measured by root mean square percentage error (% RMSE) in MBF estimates, sinogram smoothing generally provides the best MBF estimates except for the cases of the lowest simulated dose levels (tube current = 25 mAs, 2 or 3 s temporal spacing), where the KL transform method provides the best MBF estimates. The KL transform technique provides improved MBF estimates compared to conventional processing only at very low doses (<7 mSv). Results suggest that the proposed smoothing techniques could provide high fidelity MBF information and allow for substantial radiation dose savings.

Entities:  

Keywords:  dynamic computed tomography; low dose; myocardial blood flow; sinogram smoothing

Year:  2014        PMID: 25642441      PMCID: PMC4307866          DOI: 10.1117/1.JMI.1.3.034004

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  21 in total

1.  Monotonic algorithms for transmission tomography.

Authors:  H Erdoğan; J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1999-09       Impact factor: 10.048

2.  Iterative 4D cardiac micro-CT image reconstruction using an adaptive spatio-temporal sparsity prior.

Authors:  Ludwig Ritschl; Stefan Sawall; Michael Knaup; Andreas Hess; Marc Kachelriess
Journal:  Phys Med Biol       Date:  2012-03-05       Impact factor: 3.609

3.  Penalized-likelihood sinogram smoothing for low-dose CT.

Authors:  Patrick J La Rivière
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

4.  Penalized-likelihood sinogram restoration for computed tomography.

Authors:  Patrick J La Rivière; Junguo Bian; Phillip A Vargas
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

5.  Fractional flow reserve as the reference standard for myocardial perfusion studies: fool's gold?

Authors:  Sven Plein; Manish Motwani
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2013-06-21       Impact factor: 6.875

6.  Comparison of blood flow models and acquisitions for quantitative myocardial perfusion estimation from dynamic CT.

Authors:  Michael Bindschadler; Dimple Modgil; Kelley R Branch; Patrick J La Riviere; Adam M Alessio
Journal:  Phys Med Biol       Date:  2014-03-10       Impact factor: 3.609

7.  4D XCAT phantom for multimodality imaging research.

Authors:  W P Segars; G Sturgeon; S Mendonca; Jason Grimes; B M W Tsui
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

8.  Time-resolved interventional cardiac C-arm cone-beam CT: an application of the PICCS algorithm.

Authors:  Guang-Hong Chen; Pascal Theriault-Lauzier; Jie Tang; Brian Nett; Shuai Leng; Joseph Zambelli; Zhihua Qi; Nicholas Bevins; Amish Raval; Scott Reeder; Howard Rowley
Journal:  IEEE Trans Med Imaging       Date:  2011-10-20       Impact factor: 10.048

9.  Low-dose cardio-respiratory phase-correlated cone-beam micro-CT of small animals.

Authors:  Stefan Sawall; Frank Bergner; Robert Lapp; Markus Mronz; Marek Karolczak; Andreas Hess; Marc Kachelriess
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

10.  Diagnostic accuracy of fractional flow reserve from anatomic CT angiography.

Authors:  James K Min; Jonathon Leipsic; Michael J Pencina; Daniel S Berman; Bon-Kwon Koo; Carlos van Mieghem; Andrejs Erglis; Fay Y Lin; Allison M Dunning; Patricia Apruzzese; Matthew J Budoff; Jason H Cole; Farouc A Jaffer; Martin B Leon; Jennifer Malpeso; G B John Mancini; Seung-Jung Park; Robert S Schwartz; Leslee J Shaw; Laura Mauri
Journal:  JAMA       Date:  2012-09-26       Impact factor: 56.272

View more
  2 in total

1.  Variable temporal sampling and tube current modulation for myocardial blood flow estimation from dose-reduced dynamic computed tomography.

Authors:  Dimple Modgil; Michael D Bindschadler; Adam M Alessio; Patrick J La Rivière
Journal:  J Med Imaging (Bellingham)       Date:  2017-05-13

2.  Robust dynamic myocardial perfusion CT deconvolution for accurate residue function estimation via adaptive-weighted tensor total variation regularization: a preclinical study.

Authors:  Dong Zeng; Changfei Gong; Zhaoying Bian; Jing Huang; Xinyu Zhang; Hua Zhang; Lijun Lu; Shanzhou Niu; Zhang Zhang; Zhengrong Liang; Qianjin Feng; Wufan Chen; Jianhua Ma
Journal:  Phys Med Biol       Date:  2016-10-26       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.