Literature DB >> 16883113

Development and early testing of a simple subcutaneous counterpulsation device.

Steven C Koenig1, Paul A Spence, George M Pantalos, Robert D Dowling, Kenneth N Litwak.   

Abstract

The intra-aortic balloon pump has been widely and successfully used as a treatment for cardiac dysfunction, but it only has short-term applications. To overcome this limitation, a superficial counterpulsation device (CPD) is being developed to provide extended counterpulsation support to promote myocardial recovery. The CPD is a valveless, monoport, pneumatically driven, 40-ml sac that is intended to be implanted in a pacemaker-type pocket in the subclavian fossa. The sac is designed to fill in systole and empty during diastole through an outflow graft anastomosed to the subclavian artery. A feasibility study was conducted to investigate acute hemodynamic responses to the CPD in eight calves with diminished cardiac function. The CPD augmented aortic diastolic pressure, reduced left ventricular peak systolic and aortic ejection pressures by up to 18%, and increased diastolic coronary flow by up to 21% and stroke volume by up to 12%. A cadaver fit study demonstrated that the human subclavian artery is a reasonable anastomosis site to consider and that the 40-ml CPD needs to be reduced in size to provide a better anatomical fit. The clinical attractiveness of this approach is that it may provide extended support through a subcutaneous surgical procedure.

Entities:  

Mesh:

Year:  2006        PMID: 16883113      PMCID: PMC2828048          DOI: 10.1097/01.mat.0000227729.70008.66

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  18 in total

1.  Superior performance of a paraaortic counterpulsation device compared to the intraaortic balloon pump.

Authors:  John V Terrovitis; Christos E Charitos; Elias J Tsolakis; Paraskevi Dolou; Charalampos N Pierrakos; Kostas X Siafakas; John N Nanas
Journal:  World J Surg       Date:  2003-11-05       Impact factor: 3.352

2.  HEART: an automated beat-to-beat cardiovascular analysis package using Matlab.

Authors:  M J Mark J Schroeder; Bill Perreault; D L Daniel L Ewert; S C Steven C Koenig
Journal:  Comput Biol Med       Date:  2004-07       Impact factor: 4.589

Review 3.  Basic principles of the intraaortic balloon pump and mechanisms affecting its performance.

Authors:  Theodoros G Papaioannou; Christodoulos Stefanadis
Journal:  ASAIO J       Date:  2005 May-Jun       Impact factor: 2.872

4.  Predicted hemodynamic benefits of counterpulsation therapy using a superficial surgical approach.

Authors:  Guruprasad A Giridharan; George M Pantalos; Kenneth N Litwak; Paul A Spence; Steven C Koenig
Journal:  ASAIO J       Date:  2006 Jan-Feb       Impact factor: 2.872

5.  Intraaortic balloon pumping for cardiac support: trends in practice and outcome, 1968 to 1995.

Authors:  D F Torchiana; G Hirsch; M J Buckley; C Hahn; J W Allyn; C W Akins; J F Drake; J B Newell; W G Austen
Journal:  J Thorac Cardiovasc Surg       Date:  1997-04       Impact factor: 5.209

6.  Monensin toxicosis in the domestic bovine calf: a large animal model of cardiac dysfunction.

Authors:  Kenneth N Litwak; Ashley McMahan; Karen A Lott; Laura E Lott; Steven C Koenig
Journal:  Contemp Top Lab Anim Sci       Date:  2005-05

7.  Left ventricular and myocardial perfusion responses to volume unloading and afterload reduction in a computer simulation.

Authors:  Guruprasad A Giridharan; Dan L Ewert; George M Pantalos; Kevin J Gillars; Kenneth N Litwak; Laman A Gray; Steven C Koenig
Journal:  ASAIO J       Date:  2004 Sep-Oct       Impact factor: 2.872

8.  Ambulatory intraaortic balloon pump use as bridge to heart transplant.

Authors:  Richard P Cochran; Thomas D Starkey; Anthony L Panos; Karyn S Kunzelman
Journal:  Ann Thorac Surg       Date:  2002-09       Impact factor: 4.330

9.  Circulatory assistance with a permanent implantable IABP: initial human experience.

Authors:  Valluvan Jeevanandam; David Jayakar; Allen S Anderson; Suzanne Martin; William Piccione; A L Heroux; J Wynne; Larry W Stephenson; Jack Hsu; Paul S Freed; Adrian Kantrowitz
Journal:  Circulation       Date:  2002-09-24       Impact factor: 29.690

10.  Integrated data acquisition system for medical device testing and physiology research in compliance with good laboratory practices.

Authors:  Steven C Koenig; Cary Woolard; Guy Drew; Lauren Unger; Kevin Gillars; Dan Ewert; Laman Gray; George Pantalos
Journal:  Biomed Instrum Technol       Date:  2004 May-Jun
View more
  6 in total

1.  The future of adult cardiac assist devices: novel systems and mechanical circulatory support strategies.

Authors:  Carlo R Bartoli; Robert D Dowling
Journal:  Cardiol Clin       Date:  2011-11       Impact factor: 2.213

Review 2.  Continuous internal counterpulsation as a bridge to recovery in acute and chronic heart failure.

Authors:  Christos D Kontogiannis; Konstantinos Malliaras; Chris J Kapelios; Jay W Mason; John N Nanas
Journal:  World J Transplant       Date:  2016-03-24

3.  Flow dynamics of a novel counterpulsation device characterized by CFD and PIV modeling.

Authors:  G A Giridharan; C Lederer; A Berthe; L Goubergrits; J Hutzenlaub; M S Slaughter; R D Dowling; P A Spence; S C Koenig
Journal:  Med Eng Phys       Date:  2011-06-15       Impact factor: 2.242

Review 4.  Aortic counterpulsation: C-pulse and other devices for cardiac support.

Authors:  Pallavi Solanki
Journal:  J Cardiovasc Transl Res       Date:  2014-02-20       Impact factor: 4.132

5.  Acute hemodynamic efficacy of a 32-ml subcutaneous counterpulsation device in a calf model of diminished cardiac function.

Authors:  Steven C Koenig; Kenneth N Litwak; Guruprasad A Giridharan; George M Pantalos; Robert D Dowling; Sumanth D Prabhu; Mark S Slaughter; Michael A Sobieski; Paul A Spence
Journal:  ASAIO J       Date:  2008 Nov-Dec       Impact factor: 2.872

Review 6.  Evidence of clinical efficacy of counterpulsation therapy methods.

Authors:  M Capoccia; C T Bowles; J R Pepper; N R Banner; A R Simon
Journal:  Heart Fail Rev       Date:  2015-05       Impact factor: 4.214

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.