Literature DB >> 9104986

Intraaortic balloon pumping for cardiac support: trends in practice and outcome, 1968 to 1995.

D F Torchiana1, G Hirsch, M J Buckley, C Hahn, J W Allyn, C W Akins, J F Drake, J B Newell, W G Austen.   

Abstract

OBJECTIVES: A total of 4756 cases of intraaortic balloon pump support have been recorded at the Massachusetts General Hospital since the first clinical insertion for cardiogenic shock in 1968. This report describes the patterns of intraaortic balloon use and associated outcomes over this time period.
METHODS: A retrospective record review was conducted.
RESULTS: Balloon use has increased to more than 300 cases a year at present. The practice of balloon placement for control of ischemia (2453 cases, 11.9% mortality) has become more frequent, whereas support for hemodynamic decompensation (congestive heart failure, hypotension, cardiogenic shock) has been relatively constant (1760 cases, 38.2% mortality). Mean patient age has increased from 54 to 66 years, and mortality has fallen from 41% to 20%. Sixty-five percent (3097/4756) of the total patient population receiving balloon support underwent cardiac surgery. Placement before the operation (2038 patients) was associated with a lower mortality (13.6%) than intraoperative (771 patients, 35.7% mortality) or postoperative use (276 patients, 35.9% mortality). Independent predictors of death with balloon pump support were insertion in the operating room or intensive care unit, transthoracic insertion, age, procedure other than angioplasty or coronary artery bypass, and insertion for cardiogenic shock. Independent predictors of death with intraoperative balloon insertion were age, mitral valve replacement, prolonged cardiopulmonary bypass, urgent or emergency operation, preoperative renal dysfunction, complex ventricular ectopy, right ventricular failure, and emergency reinstitution of cardiopulmonary bypass.
CONCLUSIONS: Balloons are being used more frequently for control of ischemia in more patients who are elderly with lower mortality. An institutional bias toward preoperative use of the balloon pump appears to be associated with improved outcomes.

Entities:  

Mesh:

Year:  1997        PMID: 9104986     DOI: 10.1016/S0022-5223(97)70235-6

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  17 in total

1.  Development and early testing of a simple subcutaneous counterpulsation device.

Authors:  Steven C Koenig; Paul A Spence; George M Pantalos; Robert D Dowling; Kenneth N Litwak
Journal:  ASAIO J       Date:  2006 Jul-Aug       Impact factor: 2.872

2.  Predicted hemodynamic benefits of counterpulsation therapy using a superficial surgical approach.

Authors:  Guruprasad A Giridharan; George M Pantalos; Kenneth N Litwak; Paul A Spence; Steven C Koenig
Journal:  ASAIO J       Date:  2006 Jan-Feb       Impact factor: 2.872

Review 3.  Management of refractory cardiogenic shock.

Authors:  Alex Reyentovich; Maya H Barghash; Judith S Hochman
Journal:  Nat Rev Cardiol       Date:  2016-06-30       Impact factor: 32.419

4.  The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome.

Authors:  Haralabos Parissis; Michael Leotsinidis; Mohammad Tauqeer Akbar; Efstratios Apostolakis; Dimitrios Dougenis
Journal:  J Cardiothorac Surg       Date:  2010-04-05       Impact factor: 1.637

Review 5.  Cardiogenic Shock in Perioperative and Intraoperative Settings: A Team Approach.

Authors:  Faisal Masud; Gaurav Gheewala; Martin Giesecke; E E Suarez; Iqbal Ratnani
Journal:  Methodist Debakey Cardiovasc J       Date:  2020 Jan-Mar

6.  Efficacy of Subcutaneous Electrocardiogram Leads for Synchronous Timing During Chronic Counterpulsation Therapy.

Authors:  Stephen R Carnahan; Steven C Koenig; Michael A Sobieski; Erin M Schumer; Gretel Monreal; Yu Wang; Young Choi; Brek J Meuris; Landon H Tompkins; Zhongjun J Wu; Mark S Slaughter; Guruprasad A Giridharan
Journal:  ASAIO J       Date:  2017 Mar/Apr       Impact factor: 2.872

Review 7.  Aortic counterpulsation: C-pulse and other devices for cardiac support.

Authors:  Pallavi Solanki
Journal:  J Cardiovasc Transl Res       Date:  2014-02-20       Impact factor: 4.132

8.  Temporal trends in the use of intraaortic balloon pump associated with percutaneous coronary intervention in the United States, 1998-2008.

Authors:  Hiren Patel; Anupama Shivaraju; Gregg C Fonarow; Hui Xie; Weihua Gao; Adhir R Shroff; Mladen I Vidovich
Journal:  Am Heart J       Date:  2014-06-06       Impact factor: 4.749

9.  Acute hemodynamic efficacy of a 32-ml subcutaneous counterpulsation device in a calf model of diminished cardiac function.

Authors:  Steven C Koenig; Kenneth N Litwak; Guruprasad A Giridharan; George M Pantalos; Robert D Dowling; Sumanth D Prabhu; Mark S Slaughter; Michael A Sobieski; Paul A Spence
Journal:  ASAIO J       Date:  2008 Nov-Dec       Impact factor: 2.872

10.  Short-term ventricular assist device in post-cardiotomy cardiogenic shock: factors influencing survival.

Authors:  Prashant N Mohite; Anton Sabashnikov; Nikhil P Patil; Diana García Sáez; Bartlomiej Zych; Aron F Popov; Alexander Weymann; Thorsten Wahlers; Nandor Marczin; Fabio DeRobertis; Toufan Bahrami; Mohamed Amrani; André R Simon
Journal:  J Artif Organs       Date:  2014-06-01       Impact factor: 1.731

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.