Evidence of clinical efficacy of counterpulsation therapy methods.

M Capoccia1, C T Bowles, J R Pepper, N R Banner, A R Simon.   

Abstract

Although heart transplantation remains the ultimate treatment for end-stage heart failure, its epidemiological impact is limited by donor organ availability. Surgical and device-based approaches have been introduced with the aim of increasing systemic perfusion and in some circumstances promoting left ventricular recovery by inducing reverse remodelling. Innovative counterpulsation devices based on the established principle of the intra-aortic balloon pump have been developed, and of these, the CardioVad and the C-Pulse System have been introduced in clinical practice with convincing evidence of haemodynamic efficacy. The evolution from pulsatile to continuous-flow left ventricular assist devices has been associated with improved survival rates during the first 2 years of support with the potential of matching heart transplantation outcomes. However, blood contact with the device remains a significant challenge despite the highly sophisticated technology currently available. Innovative extra-vascular counterpulsation devices have been shown to overcome the limitations of the intra-aortic balloon pump and rend the device suitable for prolonged support. Monitoring of the performance of these novel devices is essential, and carotid Doppler ultrasonography is of utility in assessing the haemodynamic performance of the devices in a clinical setting. Computational modelling has played a role in the simulation of these devices and should continue to assist with their optimisation and implementation in clinical practice.

Entities:  

Mesh:

Year:  2015        PMID: 25515152     DOI: 10.1007/s10741-014-9468-1

Source DB:  PubMed          Journal:  Heart Fail Rev        ISSN: 1382-4147            Impact factor:   4.214


  97 in total

1.  Cardiac support device modifies left ventricular geometry and myocardial structure after myocardial infarction.

Authors:  Aaron S Blom; Rupak Mukherjee; James J Pilla; Abigail S Lowry; William M Yarbrough; Joseph T Mingoia; Jennifer W Hendrick; Robert E Stroud; Julie E McLean; John Affuso; Robert C Gorman; Joseph H Gorman; Michael A Acker; Francis G Spinale
Journal:  Circulation       Date:  2005-08-30       Impact factor: 29.690

2.  Determination of wave speed and wave separation in the arteries using diameter and velocity.

Authors:  J Feng; A W Khir
Journal:  J Biomech       Date:  2009-11-04       Impact factor: 2.712

3.  Intra-aortic balloon counterpulsation in cardiogenic shock. Report of a co-operative clinical trial.

Authors:  S Scheidt; G Wilner; H Mueller; D Summers; M Lesch; G Wolff; J Krakauer; M Rubenfire; P Fleming; G Noon; N Oldham; T Killip; A Kantrowitz
Journal:  N Engl J Med       Date:  1973-05-10       Impact factor: 91.245

4.  Measurement of left ventricular wall stress.

Authors:  R M Huisman; G Elzinga; N Westerhof; P Sipkema
Journal:  Cardiovasc Res       Date:  1980-03       Impact factor: 10.787

5.  A new noninvasive measurement system for wave intensity: evaluation of carotid arterial wave intensity and reproducibility.

Authors:  Kiyomi Niki; Motoaki Sugawara; Dehua Chang; Akimitsu Harada; Takashi Okada; Ryoichi Sakai; Keisuke Uchida; Rie Tanaka; Catherine E Mumford
Journal:  Heart Vessels       Date:  2002-11       Impact factor: 2.037

6.  Flow dynamics of a novel counterpulsation device characterized by CFD and PIV modeling.

Authors:  G A Giridharan; C Lederer; A Berthe; L Goubergrits; J Hutzenlaub; M S Slaughter; R D Dowling; P A Spence; S C Koenig
Journal:  Med Eng Phys       Date:  2011-06-15       Impact factor: 2.242

7.  Intra-aortic balloon pumping: does posture matter?

Authors:  Ashraf W Khir; Susana Price; Colin Hale; David A Young; Kim H Parker; John R Pepper
Journal:  Artif Organs       Date:  2005-01       Impact factor: 3.094

8.  A UK Single Centre Retrospective Analysis of the Relationship between Haemodynamic Changes and Outcome in Patients Undergoing Prolonged Left Ventricular Assist Device Support.

Authors:  Massimo Capoccia; Christopher T Bowles; Anton Sabashnikov; Fabio De Robertis; Mohamed Amrani; Nicholas R Banner; Andre Simon
Journal:  Ann Thorac Cardiovasc Surg       Date:  2014-07-11       Impact factor: 1.520

9.  Pressure and flow-volume distribution associated with intra-aortic balloon inflation: an in vitro study.

Authors:  Giovanni Biglino; Michael Whitehorne; John R Pepper; Ashraf W Khir
Journal:  Artif Organs       Date:  2008-01       Impact factor: 3.094

10.  Neurological events during long-term mechanical circulatory support for heart failure: the Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) experience.

Authors:  Ronald M Lazar; Peter A Shapiro; Brian E Jaski; Michael K Parides; Robert C Bourge; John T Watson; Laura Damme; Walter Dembitsky; Jeffrey D Hosenpud; Lopa Gupta; Anita Tierney; Tonya Kraus; Yoshifumi Naka
Journal:  Circulation       Date:  2004-05-03       Impact factor: 29.690

View more
  1 in total

1.  Synchronizing Gait with Cardiac Cycle Phase Alters Heart Rate Response during Running.

Authors:  Keren Constantini; Abigail S L Stickford; Jeffery L Bleich; Paul D Mannheimer; Benjamin D Levine; Robert F Chapman
Journal:  Med Sci Sports Exerc       Date:  2018-05       Impact factor: 5.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.