Ambulatory intraaortic balloon pump use as bridge to heart transplant.

Richard P Cochran1, Thomas D Starkey, Anthony L Panos, Karyn S Kunzelman.   

Abstract

BACKGROUND: This study evaluates a modification of an ambulatory intraaortic balloon pump (IABP) technique used in patients with heart failure of ischemic origin for bridge to transplant.
METHODS: In this retrospective review we evaluated the ability to place the ambulatory IABP, any complications, time on device, and success in bridging to transplant on the ambulatory IABP device. In addition, the cost as compared to current ventricular assist devices was determined.
RESULTS: Between July 2000 and November 2001, 4 patients have been managed with ambulatory IABP in our combined University of Wisconsin and William S. Middleton Veterans Administration programs. All 4 patients had ischemia as their mode of heart failure, and each had a relative contraindication to standard ventricular assist device use. All 4 patients had ambulatory IABPs successfully placed through the left axillary artery without complication, and were able to ambulate early after ambulatory IABP placement, and increased their rehabilitation status before transplantation. Ambulatory IABP support ranged from 12 to 70 days. All 4 patients have been successfully transplanted and discharged from the hospital. Use of the ambulatory IABP support, even with multiple replacements, translated to 10- to 50-fold savings for each of the reported patients versus standard ventricular assist device use.
CONCLUSIONS: As a result of our initial experience, we believe that ambulatory IABP is an excellent mode of support in selected patients, and is cost-effective, as compared to conventional ventricular assist device therapy.

Entities:  

Mesh:

Year:  2002        PMID: 12238834     DOI: 10.1016/s0003-4975(02)03808-0

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  11 in total

1.  Development and early testing of a simple subcutaneous counterpulsation device.

Authors:  Steven C Koenig; Paul A Spence; George M Pantalos; Robert D Dowling; Kenneth N Litwak
Journal:  ASAIO J       Date:  2006 Jul-Aug       Impact factor: 2.872

Review 2.  Radiology of cardiac devices and their complications.

Authors:  J Dipoce; A Bernheim; H Spindola-Franco
Journal:  Br J Radiol       Date:  2014-11-20       Impact factor: 3.039

Review 3.  Continuous internal counterpulsation as a bridge to recovery in acute and chronic heart failure.

Authors:  Christos D Kontogiannis; Konstantinos Malliaras; Chris J Kapelios; Jay W Mason; John N Nanas
Journal:  World J Transplant       Date:  2016-03-24

4.  Physical therapy management of two patients with stage d heart failure in the cardiac medical intensive care unit.

Authors:  Kelly Macauley
Journal:  Cardiopulm Phys Ther J       Date:  2012-09

5.  Effects of intra-aortic balloon pump counterpulsation on left ventricular mechanoenergetics in a porcine model of acute ischemic heart failure.

Authors:  Konstantinos Malliaras; Efstratios Charitos; Nikolaos Diakos; Iraklis Pozios; Apostolos Papalois; John Terrovitis; John Nanas
Journal:  J Cardiovasc Transl Res       Date:  2014-11-07       Impact factor: 4.132

6.  The Use of Intra-aortic Balloon Pump in a Real-World Setting: A Comparison between Survivors and Nonsurvivors from Acute Coronary Syndrome Treated with IABP. The Jakarta Acute Coronary Syndrome Registry.

Authors:  Surya Dharma; Iwan Dakota; Isman Firdaus; Alexander J Wardeh; J Wouter Jukema
Journal:  Int J Angiol       Date:  2013-12

Review 7.  Aortic counterpulsation: C-pulse and other devices for cardiac support.

Authors:  Pallavi Solanki
Journal:  J Cardiovasc Transl Res       Date:  2014-02-20       Impact factor: 4.132

8.  Assessing Consequences of Intraaortic Balloon Counterpulsation Versus Left Ventricular Assist Devices at the Time of Heart Transplantation.

Authors:  Anthony W Castleberry; Adam D DeVore; Kevin W Southerland; James M Meza; William D Irish; Joseph G Rogers; Carmelo A Milano; Chetan B Patel
Journal:  ASAIO J       Date:  2016 May-Jun       Impact factor: 2.872

9.  Acute hemodynamic efficacy of a 32-ml subcutaneous counterpulsation device in a calf model of diminished cardiac function.

Authors:  Steven C Koenig; Kenneth N Litwak; Guruprasad A Giridharan; George M Pantalos; Robert D Dowling; Sumanth D Prabhu; Mark S Slaughter; Michael A Sobieski; Paul A Spence
Journal:  ASAIO J       Date:  2008 Nov-Dec       Impact factor: 2.872

Review 10.  Ambulatory Intra Aortic Balloon Pump in Advanced Heart Failure.

Authors:  Syed Yaseen Naqvi; Ibrahim G Salama; Ayhan Yoruk; Leway Chen
Journal:  Card Fail Rev       Date:  2018-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.