Literature DB >> 24554288

Aortic counterpulsation: C-pulse and other devices for cardiac support.

Pallavi Solanki1.   

Abstract

Heart failure is the leading cause of hospitalization in the USA. Despite major advances in the medical and device-related therapy including chronic resynchronization therapy for management of heart failure, significant number of patients eventually require advanced cardiac therapy including mechanical circulatory support or heart transplant. Heart transplant is a gold standard for end-stage heart failure but is limited by the donor heart shortage creating a definite need for alternative effective therapies. The earliest and most common form of mechanical circulatory support is counterpulsation therapy. Annually, more than 150,000 patients worldwide receive counterpulsation therapy for various indications including cardiogenic shock or severe left ventricular dysfunction (Nanas and Moulopoulos in Cardiology, 84:156-167, 1994) and many thousands of lives are saved each year (65 % survival) (Torchiana et al. in Journal of Thoracic and Cardiovascular Surgery, 113(4):758-764, 1997). There are different types of aortic counterpulsation devices. Here, we will give an overview of different counterpulsation devices with focus on C-Pulse device. Extra-aortic balloon counterpulsation, C-Pulse (Sunshine Heart Inc., Eden Prairie, MN), is an important and novel approach in the management of patients with advanced heart failure who remain symptomatic despite optimum medical and device-based therapy. C-Pulse is designed to provide permanent, long-term, continuous partial circulatory support for New York Heart Association class III and ambulatory class IV heart failure patients. C-Pulse is a nonblood-contacting counterpulsation using an inflatable cuff around the ascending aorta, extra-aortic balloon (EAB) counterpulsation device. A pivotal, multicenter US study to assess the safety and efficacy of C- Pulse in patient with Stage C and NYHA Class III or ambulatory Class IV heart failure is in progress.

Entities:  

Mesh:

Year:  2014        PMID: 24554288     DOI: 10.1007/s12265-014-9548-6

Source DB:  PubMed          Journal:  J Cardiovasc Transl Res        ISSN: 1937-5387            Impact factor:   4.132


  41 in total

1.  Dynamic aortomyoplasty in treating end-stage heart failure.

Authors:  Jorge Trainini; Edmundo I Cabrera Fischer; José Barisani; Alejandra I Christen; Jorge Mouras; Jorge de Paz; Benjamín Elencwajg; Juan Carlos Chachques
Journal:  J Heart Lung Transplant       Date:  2002-10       Impact factor: 10.247

2.  Experimental augmentation of coronary flow by retardation of the arterial pressure pulse.

Authors:  A KANTROWITZ
Journal:  Surgery       Date:  1953-10       Impact factor: 3.982

3.  Improved exercise tolerance following enhanced external counterpulsation: cardiac or peripheral effect?

Authors:  W E Lawson; J C Hui; Z S Zheng; L Burgen; L Jiang; O Lillis; Z Oster; H Soroff; P Cohn
Journal:  Cardiology       Date:  1996 Jul-Aug       Impact factor: 1.869

4.  Executive summary: heart disease and stroke statistics--2010 update: a report from the American Heart Association.

Authors:  Donald Lloyd-Jones; Robert J Adams; Todd M Brown; Mercedes Carnethon; Shifan Dai; Giovanni De Simone; T Bruce Ferguson; Earl Ford; Karen Furie; Cathleen Gillespie; Alan Go; Kurt Greenlund; Nancy Haase; Susan Hailpern; P Michael Ho; Virginia Howard; Brett Kissela; Steven Kittner; Daniel Lackland; Lynda Lisabeth; Ariane Marelli; Mary M McDermott; James Meigs; Dariush Mozaffarian; Michael Mussolino; Graham Nichol; Véronique L Roger; Wayne Rosamond; Ralph Sacco; Paul Sorlie; Randall Stafford; Thomas Thom; Sylvia Wasserthiel-Smoller; Nathan D Wong; Judith Wylie-Rosett
Journal:  Circulation       Date:  2010-02-23       Impact factor: 29.690

5.  Comparative effects of therapy with captopril and digoxin in patients with mild to moderate heart failure. The Captopril-Digoxin Multicenter Research Group.

Authors: 
Journal:  JAMA       Date:  1988 Jan 22-29       Impact factor: 56.272

6.  Intra-aortic balloon counterpulsation in cardiogenic shock. Report of a co-operative clinical trial.

Authors:  S Scheidt; G Wilner; H Mueller; D Summers; M Lesch; G Wolff; J Krakauer; M Rubenfire; P Fleming; G Noon; N Oldham; T Killip; A Kantrowitz
Journal:  N Engl J Med       Date:  1973-05-10       Impact factor: 91.245

7.  Effects of intraaortic balloon pumping on organ perfusion in cardiogenic shock.

Authors:  J N Bhayana; S M Scott; G K Sethi; T Takaro
Journal:  J Surg Res       Date:  1979-02       Impact factor: 2.192

8.  Ascending versus descending aortic balloon pumping: organ and myocardial perfusion during ischemia.

Authors:  B P Meyns; Y Nishimura; R Jashari; R Racz; V H Leunens; W J Flameng
Journal:  Ann Thorac Surg       Date:  2000-10       Impact factor: 4.330

9.  Enhanced coronary blood flow velocity during intraaortic balloon counterpulsation in critically ill patients.

Authors:  M J Kern; F V Aguirre; S Tatineni; D Penick; H Serota; T Donohue; K Walter
Journal:  J Am Coll Cardiol       Date:  1993-02       Impact factor: 24.094

10.  Effects of intraaortic balloon pumping on coronary hemodynamics after coronary angioplasty in patients with acute myocardial infarction.

Authors:  M Ishihara; H Sato; H Tateishi; T Kawagoe; Y Muraoka; M Yoshimura
Journal:  Am Heart J       Date:  1992-11       Impact factor: 4.749

View more
  5 in total

1.  Novel non-pharmacological approaches to heart failure.

Authors:  William T Abraham; Gaetano M De Ferrari
Journal:  J Cardiovasc Transl Res       Date:  2014-03-27       Impact factor: 4.132

Review 2.  An ambulatory counterpulsation system-a potential option for extended mechanical support.

Authors:  Trever Symalla; Valluvan Jeevanandam
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2020-01-27

Review 3.  Continuous internal counterpulsation as a bridge to recovery in acute and chronic heart failure.

Authors:  Christos D Kontogiannis; Konstantinos Malliaras; Chris J Kapelios; Jay W Mason; John N Nanas
Journal:  World J Transplant       Date:  2016-03-24

4.  Effects of intra-aortic balloon pump counterpulsation on left ventricular mechanoenergetics in a porcine model of acute ischemic heart failure.

Authors:  Konstantinos Malliaras; Efstratios Charitos; Nikolaos Diakos; Iraklis Pozios; Apostolos Papalois; John Terrovitis; John Nanas
Journal:  J Cardiovasc Transl Res       Date:  2014-11-07       Impact factor: 4.132

5.  Preliminary Results From the C-Pulse OPTIONS HF European Multicenter Post-Market Study.

Authors:  Antonia Schulz; Thomas Krabatsch; Jan D Schmitto; Roland Hetzer; Mirko Seidel; Pascal M Dohmen; Holger Hotz
Journal:  Med Sci Monit Basic Res       Date:  2016-02-18
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.