HEART: an automated beat-to-beat cardiovascular analysis package using Matlab.

M J Mark J Schroeder1, Bill Perreault, D L Daniel L Ewert, S C Steven C Koenig.   

Abstract

A computer program is described for beat-to-beat analysis of cardiovascular parameters from high-fidelity pressure and flow waveforms. The Hemodynamic Estimation and Analysis Research Tool (HEART) is a post-processing analysis software package developed in Matlab that enables scientists and clinicians to document, load, view, calibrate, and analyze experimental data that have been digitally saved in ascii or binary format. Analysis routines include traditional hemodynamic parameter estimates as well as more sophisticated analyses such as lumped arterial model parameter estimation and vascular impedance frequency spectra. Cardiovascular parameter values of all analyzed beats can be viewed and statistically analyzed. An attractive feature of the HEART program is the ability to analyze data with visual quality assurance throughout the process, thus establishing a framework toward which Good Laboratory Practice (GLP) compliance can be obtained. Additionally, the development of HEART on the Matlab platform provides users with the flexibility to adapt or create study specific analysis files according to their specific needs. Copyright 2003 Elsevier Ltd.

Mesh:

Year:  2004        PMID: 15145710     DOI: 10.1016/S0010-4825(03)00087-8

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  11 in total

1.  A new pulse duplicator with a passive fill ventricle for analysis of cardiac dynamics.

Authors:  Yoshimasa Yokoyama; Osamu Kawaguchi; Tadahiko Shinshi; Ulrich Steinseifer; Setsuo Takatani
Journal:  J Artif Organs       Date:  2010-09-28       Impact factor: 1.731

2.  Development and early testing of a simple subcutaneous counterpulsation device.

Authors:  Steven C Koenig; Paul A Spence; George M Pantalos; Robert D Dowling; Kenneth N Litwak
Journal:  ASAIO J       Date:  2006 Jul-Aug       Impact factor: 2.872

3.  Predicted hemodynamic benefits of counterpulsation therapy using a superficial surgical approach.

Authors:  Guruprasad A Giridharan; George M Pantalos; Kenneth N Litwak; Paul A Spence; Steven C Koenig
Journal:  ASAIO J       Date:  2006 Jan-Feb       Impact factor: 2.872

4.  Performance evaluation of a pediatric viscous impeller pump for Fontan cavopulmonary assist.

Authors:  Guruprasad A Giridharan; Steven C Koenig; Jeffrey Kennington; Michael A Sobieski; Jun Chen; Steven H Frankel; Mark D Rodefeld
Journal:  J Thorac Cardiovasc Surg       Date:  2012-03-14       Impact factor: 5.209

5.  Nonphysiologic blood flow triggers endothelial and arterial remodeling in vivo: implications for novel left ventricular assist devices with a peripheral anastomosis.

Authors:  Carlo R Bartoli; Paul A Spence; Thorsten Siess; Daniel H Raess; Steven C Koenig; Robert D Dowling
Journal:  J Thorac Cardiovasc Surg       Date:  2013-12-09       Impact factor: 5.209

6.  Early feasibility testing and engineering development of the transapical approach for the HeartWare MVAD ventricular assist system.

Authors:  Daniel Tamez; Jeffrey A LaRose; Charles Shambaugh; Katherine Chorpenning; Kevin G Soucy; Michael A Sobieski; Leslie Sherwood; Guruprasad A Giridharan; Gretel Monreal; Steven C Koenig; Mark S Slaughter
Journal:  ASAIO J       Date:  2014 Mar-Apr       Impact factor: 2.872

7.  Transapical miniaturized ventricular assist device: design and initial testing.

Authors:  Mark S Slaughter; Guruprasad A Giridharan; Dan Tamez; Jeff LaRose; Mike A Sobieski; Leslie Sherwood; Steven C Koenig
Journal:  J Thorac Cardiovasc Surg       Date:  2011-02-12       Impact factor: 5.209

8.  Extracorporeal membrane oxygenation versus counterpulsatile, pulsatile, and continuous left ventricular unloading for pediatric mechanical circulatory support.

Authors:  Carlo R Bartoli; Steven C Koenig; Constantine Ionan; Kevin J Gillars; Mike E Mitchell; Erle H Austin; Laman A Gray; George M Pantalos
Journal:  Pediatr Crit Care Med       Date:  2013-11       Impact factor: 3.624

9.  Acute hemodynamic efficacy of a 32-ml subcutaneous counterpulsation device in a calf model of diminished cardiac function.

Authors:  Steven C Koenig; Kenneth N Litwak; Guruprasad A Giridharan; George M Pantalos; Robert D Dowling; Sumanth D Prabhu; Mark S Slaughter; Michael A Sobieski; Paul A Spence
Journal:  ASAIO J       Date:  2008 Nov-Dec       Impact factor: 2.872

10.  End-diastolic flow reversal limits the efficacy of pediatric intra-aortic balloon pump counterpulsation.

Authors:  Carlo R Bartoli; Benjamin D Rogers; Constantine E Ionan; George M Pantalos
Journal:  J Thorac Cardiovasc Surg       Date:  2013-10-15       Impact factor: 5.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.