Literature DB >> 16820270

Development of a four-dimensional image-guided radiotherapy system with a gimbaled X-ray head.

Yuichiro Kamino1, Kenji Takayama, Masaki Kokubo, Yuichiro Narita, Etsuro Hirai, Noriyuki Kawawda, Takashi Mizowaki, Yasushi Nagata, Takehiro Nishidai, Masahiro Hiraoka.   

Abstract

PURPOSE: To develop and evaluate a new four-dimensional image-guided radiotherapy system, which enables precise setup, real-time tumor tracking, and pursuit irradiation. METHODS AND MATERIALS: The system has an innovative gimbaled X-ray head that enables small-angle (+/-2.4 degrees ) rotations (pan and tilt) along the two orthogonal gimbals. This design provides for both accurate beam positioning at the isocenter by actively compensating for mechanical distortion and quick pursuit of the target. The X-ray head is composed of an ultralight C-band linear accelerator and a multileaf collimator. The gimbaled X-ray head is mounted on a rigid O-ring structure with an on-board imaging subsystem composed of two sets of kilovoltage X-ray tubes and flat panel detectors, which provides a pair of radiographs, cone beam computed tomography images useful for image guided setup, and real-time fluoroscopic monitoring for pursuit irradiation.
RESULTS: The root mean square accuracy of the static beam positioning was 0.1 mm for 360 degrees of O-ring rotation. The dynamic beam response and positioning accuracy was +/-0.6 mm for a 0.75 Hz, 40-mm stroke and +/-0.4 mm for a 2.0 Hz, 8-mm stroke. The quality of the images was encouraging for using the tomography-based setup. Fluoroscopic images were sufficient for monitoring and tracking lung tumors.
CONCLUSIONS: Key functions and capabilities of our new system are very promising for precise image-guided setup and for tracking and pursuit irradiation of a moving target.

Entities:  

Mesh:

Year:  2006        PMID: 16820270     DOI: 10.1016/j.ijrobp.2006.04.044

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  53 in total

1.  The dosimetric impact of inversely optimized arc radiotherapy plan modulation for real-time dynamic MLC tracking delivery.

Authors:  Marianne Falk; Tobias Larsson; Paul Keall; Byung Chul Cho; Marianne Aznar; Stine Korreman; Per Poulsen; Per Munck Af Rosenschold
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  [Image-guided radiation therapy].

Authors:  J Boda-Heggemann; M Guckenberger; U Ganswindt; C Belka; H Wertz; M Blessing; F Wenz; M Fuss; F Lohr
Journal:  Radiologe       Date:  2012-03       Impact factor: 0.635

3.  Theoretical aspects of implementation of kilovoltage cone-beam CT onboard linear accelerator for image-guided radiotherapy.

Authors:  Marta Rodríguez Cordón; Carlos Ferrer Albiach
Journal:  Clin Transl Oncol       Date:  2009-08       Impact factor: 3.405

4.  Experimental investigation of a moving averaging algorithm for motion perpendicular to the leaf travel direction in dynamic MLC target tracking.

Authors:  Jai-Woong Yoon; Amit Sawant; Yelin Suh; Byung-Chul Cho; Tae-Suk Suh; Paul Keall
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

5.  Effect of image quality on correlation modeling error using a fiducial marker in a gimbaled linear accelerator.

Authors:  Hideharu Miura; Shuichi Ozawa; Tsubasa Enosaki; Fumika Hosono; Kiyoshi Yamada; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2019-02-25

6.  Effect of tumor amplitude and frequency on 4D modeling of Vero4DRT system.

Authors:  Hideharu Miura; Shuichi Ozawa; Masahiro Hayata; Shintaro Tsuda; Kiyoshi Yamada; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2017-05-05

7.  Evaluation of cone-beam computed tomography image quality assurance for Vero4DRT system.

Authors:  Hideharu Miura; Shuichi Ozawa; Masahiro Hayata; Shintarou Tsuda; Tsubasa Enosaki; Kiyoshi Yamada; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2017-04-25

8.  Experimental investigation of a general real-time 3D target localization method using sequential kV imaging combined with respiratory monitoring.

Authors:  Byungchul Cho; Per Poulsen; Dan Ruan; Amit Sawant; Paul J Keall
Journal:  Phys Med Biol       Date:  2012-10-24       Impact factor: 3.609

9.  Management of three-dimensional intrafraction motion through real-time DMLC tracking.

Authors:  Amit Sawant; Raghu Venkat; Vikram Srivastava; David Carlson; Sergey Povzner; Herb Cattell; Paul Keall
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

10.  Stereotactic body radiotherapy for pulmonary metastases. Prognostic factors and adverse respiratory events.

Authors:  T Inoue; R-J Oh; H Shiomi; N Masai; H Miura
Journal:  Strahlenther Onkol       Date:  2013-02-20       Impact factor: 3.621

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.