Literature DB >> 19661025

Theoretical aspects of implementation of kilovoltage cone-beam CT onboard linear accelerator for image-guided radiotherapy.

Marta Rodríguez Cordón1, Carlos Ferrer Albiach.   

Abstract

The main objective of image-guided radiation therapy (IGRT) equipment is to reduce and correct inherent errors in external radiotherapy processes. At the present time, there are different IGRT systems available, but here we will refer exclusively to the kilovoltage cone-beam CT onboard linear accelerator (CBkVCT) and the different aspects that, from a clinical point of view, should be taken into consideration before the implementation of this equipment.

Mesh:

Year:  2009        PMID: 19661025     DOI: 10.1007/s12094-009-0395-x

Source DB:  PubMed          Journal:  Clin Transl Oncol        ISSN: 1699-048X            Impact factor:   3.405


  12 in total

1.  Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58.

Authors:  M G Herman; J M Balter; D A Jaffray; K P McGee; P Munro; S Shalev; M Van Herk; J W Wong
Journal:  Med Phys       Date:  2001-05       Impact factor: 4.071

Review 2.  Ultrasound-based localization.

Authors:  Deborah A Kuban; Lei Dong; Rex Cheung; Eric Strom; Renaud De Crevoisier
Journal:  Semin Radiat Oncol       Date:  2005-07       Impact factor: 5.934

Review 3.  Clinical use of electronic portal imaging.

Authors:  Michael G Herman
Journal:  Semin Radiat Oncol       Date:  2005-07       Impact factor: 5.934

Review 4.  Optically guided patient positioning techniques.

Authors:  Sanford L Meeks; Wolfgang A Tomé; Tywla R Willoughby; Patrick A Kupelian; Thomas H Wagner; John M Buatti; Francis J Bova
Journal:  Semin Radiat Oncol       Date:  2005-07       Impact factor: 5.934

Review 5.  Computed tomography guided management of interfractional patient variation.

Authors:  Di Yan; David Lockman; Alvaro Martinez; John Wong; Donald Brabbins; Frank Vicini; Jian Liang; Larry Kestin
Journal:  Semin Radiat Oncol       Date:  2005-07       Impact factor: 5.934

6.  Introduction: management of target localization uncertainties in external-beam therapy.

Authors:  Gig S Mageras
Journal:  Semin Radiat Oncol       Date:  2005-07       Impact factor: 5.934

7.  Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy.

Authors:  Patrick Kupelian; Twyla Willoughby; Arul Mahadevan; Toufik Djemil; Geoffrey Weinstein; Shirish Jani; Charles Enke; Timothy Solberg; Nicholas Flores; David Liu; David Beyer; Lisa Levine
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-12-21       Impact factor: 7.038

Review 8.  Overview of image-guided radiation therapy.

Authors:  Lei Xing; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Tian-Fang Li; Gwe-Ya Kim; Gary Luxton; Albert Koong
Journal:  Med Dosim       Date:  2006       Impact factor: 1.482

Review 9.  Developments in and experience of kilovoltage X-ray cone beam image-guided radiotherapy.

Authors:  C J Moore; A Amer; T Marchant; J R Sykes; J Davies; J Stratford; C McCarthy; C MacBain; A Henry; P Price; P C Williams
Journal:  Br J Radiol       Date:  2006-09       Impact factor: 3.039

10.  Application of dose compensation in image-guided radiotherapy of prostate cancer.

Authors:  Qiuwen Wu; Jian Liang; Di Yan
Journal:  Phys Med Biol       Date:  2006-02-21       Impact factor: 3.609

View more
  1 in total

1.  Uncertainties and CTV to PTV margins quantitative assessment using cone-beam CT technique in clinical application for prostate, and head and neck irradiation tumours.

Authors:  X J Juan-Senabre; J López-Tarjuelo; A Conde-Moreno; A Santos-Serra; A L Sánchez-Iglesias; J D Quirós-Higueras; N de Marco Blancas; S Calzada-Feliu; C Ferrer-Albiach
Journal:  Clin Transl Oncol       Date:  2011-11       Impact factor: 3.405

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.