Literature DB >> 28507458

Effect of tumor amplitude and frequency on 4D modeling of Vero4DRT system.

Hideharu Miura1, Shuichi Ozawa1,2, Masahiro Hayata1, Shintaro Tsuda1, Kiyoshi Yamada1, Yasushi Nagata1,2.   

Abstract

BACKGROUND: An important issue in indirect dynamic tumor tracking with the Vero4DRT system is the accuracy of the model predictions of the internal target position based on surrogate infrared (IR) marker measurement. We investigated the predictive uncertainty of 4D modeling using an external IR marker, focusing on the effect of the target and surrogate amplitudes and periods.
METHODS: A programmable respiratory motion table was used to simulate breathing induced organ motion. Sinusoidal motion sequences were produced by a dynamic phantom with different amplitudes and periods. To investigate the 4D modeling error, the following amplitudes (peak-to-peak: 10-40 mm) and periods (2-8 s) were considered. The 95th percentile 4D modeling error (4D-E95%) between the detected and predicted target position (μ + 2SD) was calculated to investigate the 4D modeling error.
RESULTS: 4D-E95% was linearly related to the target motion amplitude with a coefficient of determination R2 = 0.99 and ranged from 0.21 to 0.88 mm. The 4D modeling error ranged from 1.49 to 0.14 mm and gradually decreased with increasing target motion period.
CONCLUSIONS: We analyzed the predictive error in 4D modeling and the error due to the amplitude and period of target. 4D modeling error substantially increased with increasing amplitude and decreasing period of the target motion.

Entities:  

Keywords:  Correlation model; IR tracking; Predictive uncertainty; Respiratory surrogates; Vero4DRT

Year:  2017        PMID: 28507458      PMCID: PMC5422005          DOI: 10.1016/j.rpor.2017.02.012

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  18 in total

1.  Dosimetric characterization of a multileaf collimator for a new four-dimensional image-guided radiotherapy system with a gimbaled x-ray head, MHI-TM2000.

Authors:  Mitsuhiro Nakamura; Akira Sawada; Yoshitomo Ishihara; Kenji Takayama; Takashi Mizowaki; Shuji Kaneko; Mikiko Yamashita; Hiroaki Tanabe; Masaki Kokubo; Masahiro Hiraoka
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Will IGRT live up to its promise?

Authors:  Marcel Van Herk
Journal:  Acta Oncol       Date:  2008       Impact factor: 4.089

3.  Positioning accuracy of a new image-guided radiotherapy system.

Authors:  Yuki Miyabe; Akira Sawada; Kenji Takayama; Shuji Kaneko; Takashi Mizowaki; Masaki Kokubo; Masahiro Hiraoka
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

4.  Accuracy verification of infrared marker-based dynamic tumor-tracking irradiation using the gimbaled x-ray head of the Vero4DRT (MHI-TM2000).

Authors:  Nobutaka Mukumoto; Mitsuhiro Nakamura; Akira Sawada; Yasunobu Suzuki; Kunio Takahashi; Yuki Miyabe; Shuji Kaneko; Takashi Mizowaki; Masaki Kokubo; Masahiro Hiraoka
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

5.  Evaluation of microscopic tumor extension in non-small-cell lung cancer for three-dimensional conformal radiotherapy planning.

Authors:  P Giraud; M Antoine; A Larrouy; B Milleron; P Callard; Y De Rycke; M F Carette; J C Rosenwald; J M Cosset; M Housset; E Touboul
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-11-01       Impact factor: 7.038

6.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy.

Authors:  H Shirato; S Shimizu; T Kunieda; K Kitamura; M van Herk; K Kagei; T Nishioka; S Hashimoto; K Fujita; H Aoyama; K Tsuchiya; K Kudo; K Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-11-01       Impact factor: 7.038

7.  Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer.

Authors:  D Mah; J Hanley; K E Rosenzweig; E Yorke; L Braban; C C Ling; S A Leibel; G Mageras
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-11-01       Impact factor: 7.038

8.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

Authors:  Paul J Keall; Gig S Mageras; James M Balter; Richard S Emery; Kenneth M Forster; Steve B Jiang; Jeffrey M Kapatoes; Daniel A Low; Martin J Murphy; Brad R Murray; Chester R Ramsey; Marcel B Van Herk; S Sastry Vedam; John W Wong; Ellen Yorke
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

9.  Respiration tracking in radiosurgery.

Authors:  Achim Schweikard; Hiroya Shiomi; John Adler
Journal:  Med Phys       Date:  2004-10       Impact factor: 4.071

10.  Simple quality assurance method of dynamic tumor tracking with the gimbaled linac system using a light field.

Authors:  Hideharu Miura; Shuichi Ozawa; Masahiro Hayata; Shintaro Tsuda; Kiyoshi Yamada; Yasushi Nagata
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

View more
  1 in total

1.  Effect of image quality on correlation modeling error using a fiducial marker in a gimbaled linear accelerator.

Authors:  Hideharu Miura; Shuichi Ozawa; Tsubasa Enosaki; Fumika Hosono; Kiyoshi Yamada; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2019-02-25
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.