Literature DB >> 16779561

Signal decay correction in 2D ultra-short echo time imaging.

Detlef Mentrup1, Holger Eggers.   

Abstract

OBJECTIVES: In ultra-short echo time (UTE) imaging, the transverse magnetization experiences significant decay during data acquisition, which gives rise to a loss of signal intensity and spatial resolution in conventionally reconstructed images. The present work proposes an iterative algorithm to correct these adverse effects.
MATERIALS AND METHODS: The algorithm involves solving a large linear system of equations and requires a separate reference scan to map the spatially variant transverse relaxation time. It was implemented and applied to simulations and to experiments with custom-built resolution phantoms. The evaluation focused on its ability to improve the actual point-spread function (PSF) and on its influence upon the local signal-to-noise ratio (SNR).
RESULTS: The algorithm is demonstrated to virtually restore the ideal PSF of the acquisition. It proves to provide images with better signal intensity and spatial resolution but reduced SNR, if the transverse relaxation time is known with sufficient accuracy.
CONCLUSIONS: The present work shows the basic feasibility of correcting signal decay effects in UTE imaging.

Mesh:

Year:  2006        PMID: 16779561     DOI: 10.1007/s10334-006-0028-0

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  13 in total

1.  Postprocessing technique to correct for background gradients in image-based R*(2) measurements.

Authors:  M A Fernández-Seara; F W Wehrli
Journal:  Magn Reson Med       Date:  2000-09       Impact factor: 4.668

2.  Fast, iterative image reconstruction for MRI in the presence of field inhomogeneities.

Authors:  Bradley P Sutton; Douglas C Noll; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2003-02       Impact factor: 10.048

Review 3.  Magnetic resonance: an introduction to ultrashort TE (UTE) imaging.

Authors:  Matthew D Robson; Peter D Gatehouse; Mark Bydder; Graeme M Bydder
Journal:  J Comput Assist Tomogr       Date:  2003 Nov-Dec       Impact factor: 1.826

4.  Parsing local signal evolution directly from a single-shot MRI signal: a new approach for fMRI.

Authors:  Donald B Twieg
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

5.  Convergence behavior of iterative SENSE reconstruction with non-Cartesian trajectories.

Authors:  Peng Qu; Kai Zhong; Bida Zhang; Jianmin Wang; Gary X Shen
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

6.  A fast sinc function gridding algorithm for fourier inversion in computer tomography.

Authors:  J D O'Sullivan
Journal:  IEEE Trans Med Imaging       Date:  1985       Impact factor: 10.048

7.  A homogeneity correction method for magnetic resonance imaging with time-varying gradients.

Authors:  D C Noll; C H Meyer; J M Pauly; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

8.  Algebraic reconstruction for magnetic resonance imaging under B0 inhomogeneity.

Authors:  Y M Kadah; X Hu
Journal:  IEEE Trans Med Imaging       Date:  1998-06       Impact factor: 10.048

9.  Multifrequency interpolation for fast off-resonance correction.

Authors:  L C Man; J M Pauly; A Macovski
Journal:  Magn Reson Med       Date:  1997-05       Impact factor: 4.668

10.  Magnetic resonance imaging of periosteum with ultrashort TE pulse sequences.

Authors:  Ines L H Reichert; Michael Benjamin; Peter D Gatehouse; Karyn E Chappell; Joanne Holmes; Taigang He; Graeme M Bydder
Journal:  J Magn Reson Imaging       Date:  2004-01       Impact factor: 4.813

View more
  3 in total

1.  High-resolution sodium imaging of human brain at 7 T.

Authors:  Yongxian Qian; Tiejun Zhao; Hai Zheng; Jonathan Weimer; Fernando E Boada
Journal:  Magn Reson Med       Date:  2011-12-05       Impact factor: 4.668

Review 2.  Quantitative sodium MR imaging: A review of its evolving role in medicine.

Authors:  Keith R Thulborn
Journal:  Neuroimage       Date:  2016-11-24       Impact factor: 6.556

3.  MRI chemical shift artifact produced by center-out radial sampling of k-space: a potential pitfall in clinical diagnosis.

Authors:  Mark Bydder; Michael Carl; Graeme M Bydder; Jiang Du
Journal:  Quant Imaging Med Surg       Date:  2021-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.