Algebraic reconstruction for magnetic resonance imaging under B0 inhomogeneity.

Y M Kadah1, X Hu.   

Abstract

In magnetic resonance imaging, spatial localization is usually achieved using Fourier encoding which is realized by applying a magnetic field gradient along the dimension of interest to create a linear correspondence between the resonance frequency and spatial location following the Larmor equation. In the presence of B0 inhomogeneities along this dimension, the linear mapping does not hold and spatial distortions arise in the acquired images. In this paper, the problem of image reconstruction under an inhomogeneous field is formulated as an inverse problem of a linear Fredholm equation of the first kind. The operators in these problems are estimated using field mapping and the k-space trajectory of the imaging sequence. Since such inverse problems are known to be ill-posed in general, robust solvers, singular value decomposition and conjugate gradient method, are employed to obtain corrected images that are optimal in the Frobenius norm sense. Based on this formulation, the choice of the imaging sequence for well-conditioned matrix operators is discussed, and it is shown that nonlinear k-space trajectories provide better results. The reconstruction technique is applied to sequences where the distortion is more severe along one of the image dimensions and the two-dimensional reconstruction problem becomes equivalent to a set of independent one-dimensional problems. Experimental results demonstrate the performance and stability of the algebraic reconstruction methods.

Mesh:

Year:  1998        PMID: 9735900     DOI: 10.1109/42.712126

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  11 in total

1.  Signal decay correction in 2D ultra-short echo time imaging.

Authors:  Detlef Mentrup; Holger Eggers
Journal:  MAGMA       Date:  2006-05-09       Impact factor: 2.310

2.  Hybrid two-dimensional navigator correction: a new technique to suppress respiratory-induced physiological noise in multi-shot echo-planar functional MRI.

Authors:  Robert L Barry; L Martyn Klassen; Joy M Williams; Ravi S Menon
Journal:  Neuroimage       Date:  2007-10-11       Impact factor: 6.556

3.  Concurrent correction of geometric distortion and motion using the map-slice-to-volume method in echo-planar imaging.

Authors:  Desmond T B Yeo; Jeffrey A Fessler; Boklye Kim
Journal:  Magn Reson Imaging       Date:  2008-02-15       Impact factor: 2.546

4.  Spatial phase encoding exploiting the Bloch-Siegert shift effect.

Authors:  Ralf Kartäusch; Toni Driessle; Thomas Kampf; Thomas Christian Basse-Lüsebrink; Uvo Christoph Hoelscher; Peter Michael Jakob; Florian Fidler; Xavier Helluy
Journal:  MAGMA       Date:  2013-11-20       Impact factor: 2.310

5.  Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: application to cardiac cine.

Authors:  Shu Li; Cheong Chan; Jason P Stockmann; Hemant Tagare; Ganesh Adluru; Leo K Tam; Gigi Galiana; R Todd Constable; Sebastian Kozerke; Dana C Peters
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

6.  Iterative image reconstruction that includes a total variation regularization for radial MRI.

Authors:  Shinya Kojima; Hiroyuki Shinohara; Takeyuki Hashimoto; Masami Hirata; Eiko Ueno
Journal:  Radiol Phys Technol       Date:  2015-05-20

7.  Co-registration and distortion correction of diffusion and anatomical images based on inverse contrast normalization.

Authors:  Chitresh Bhushan; Justin P Haldar; Soyoung Choi; Anand A Joshi; David W Shattuck; Richard M Leahy
Journal:  Neuroimage       Date:  2015-03-27       Impact factor: 6.556

Review 8.  Clinical magnetic resonance imaging of brain tumors at ultrahigh field: a state-of-the-art review.

Authors:  William T C Yuh; Greg A Christoforidis; Regina Maria Koch; Steffen Sammet; Petra Schmalbrock; Ming Yang; Michael V Knopp
Journal:  Top Magn Reson Imaging       Date:  2006-04

9.  Quantitative sodium imaging with a flexible twisted projection pulse sequence.

Authors:  Aiming Lu; Ian C Atkinson; Theodore C Claiborne; Frederick C Damen; Keith R Thulborn
Journal:  Magn Reson Med       Date:  2010-06       Impact factor: 4.668

10.  A joint acquisition-reconstruction paradigm for correcting inhomogeneity artifacts in MR echo planar imaging.

Authors:  Joseph C Dagher; François G Meyer
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.