Literature DB >> 14587015

Parsing local signal evolution directly from a single-shot MRI signal: a new approach for fMRI.

Donald B Twieg1.   

Abstract

In this work a new single-shot MRI method, single-shot parameter assessment by retrieval from signal encoding (SS-PARSE), is introduced. This method abandons a fundamental simplifying assumption that is used in conventional MRI methods. Established MRI methods implicitly assume that the local intrinsic signal does not change its amplitude or phase during signal acquisition, even though these changes may be substantial, especially during the relatively long signals used in single-shot image acquisitions. SS-PARSE, on the other hand, acknowledges local decay and phase evolution, and models each signal datum as a sample from (k,t)-space rather than k-space. Because of this more accurate signal model, SS-PARSE promises improved performance in terms of accuracy and robustness, but requires more intensive reconstruction computations. The theoretical properties of the method are discussed, and simulation results are presented that demonstrate more robust and accurate measurements of relaxation rate changes associated with brain activation in functional MRI (fMRI), freedom from geometric errors due to off-resonance frequencies, and better tolerance of the large susceptibility gradients that occur naturally in parts of the brain. In addition, this technique has the potential to assess nonexponential relaxation behavior during a single-shot signal. Copyright 2003 Wiley-Liss, Inc.

Mesh:

Year:  2003        PMID: 14587015     DOI: 10.1002/mrm.10613

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  MODEL-BASED IMAGE RECONSTRUCTION FOR MRI.

Authors:  Jeffrey A Fessler
Journal:  IEEE Signal Process Mag       Date:  2010-07-01       Impact factor: 12.551

2.  Signal decay correction in 2D ultra-short echo time imaging.

Authors:  Detlef Mentrup; Holger Eggers
Journal:  MAGMA       Date:  2006-05-09       Impact factor: 2.310

3.  Validation of V-SS-PARSE for single-shot flow measurement.

Authors:  Jin Zuo; Mark Bolding; Donald B Twieg
Journal:  Magn Reson Imaging       Date:  2006-11-13       Impact factor: 2.546

4.  Snapshot MR technique to measure OEF using rapid frequency mapping.

Authors:  Rajiv G Menon; Edward G Walsh; Donald B Twieg; Charles G Cantrell; Parmede Vakil; Sumeeth V Jonathan; Hunt H Batjer; Timothy J Carroll
Journal:  J Cereb Blood Flow Metab       Date:  2014-04-23       Impact factor: 6.200

5.  Basic properties of SS-PARSE parameter estimates.

Authors:  Donald B Twieg; Stanley J Reeves
Journal:  IEEE Trans Med Imaging       Date:  2010-03-18       Impact factor: 10.048

6.  Spin-echo SS-PARSE: a PARSE MRI method to estimate frequency, R(2) and R(2)(') in a single shot.

Authors:  Ningzhi Li; Mark Bolding; Donald B Twieg
Journal:  Magn Reson Imaging       Date:  2010-08-07       Impact factor: 2.546

Review 7.  Current trends and challenges in MRI acquisitions to investigate brain function.

Authors:  Bradley P Sutton; Cheng Ouyang; Dimitrios C Karampinos; Gregory A Miller
Journal:  Int J Psychophysiol       Date:  2009-02-21       Impact factor: 2.997

8.  Regularized field map estimation in MRI.

Authors:  Amanda K Funai; Jeffrey A Fessler; Desmond T B Yeo; Valur T Olafsson; Douglas C Noll
Journal:  IEEE Trans Med Imaging       Date:  2008-10       Impact factor: 10.048

9.  Directional and inter-acquisition variability in diffusion-weighted imaging and editing for restricted diffusion.

Authors:  Batuhan Gundogdu; Jay M Pittman; Aritrick Chatterjee; Teodora Szasz; Grace Lee; Mihai Giurcanu; Milica Medved; Roger Engelmann; Xiaodong Guo; Ambereen Yousuf; Tatjana Antic; Ajit Devaraj; Xiaobing Fan; Aytekin Oto; Gregory S Karczmar
Journal:  Magn Reson Med       Date:  2022-07-21       Impact factor: 3.737

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.