Literature DB >> 10975885

Postprocessing technique to correct for background gradients in image-based R*(2) measurements.

M A Fernández-Seara1, F W Wehrli.   

Abstract

Background static magnetic field gradients are a source of signal loss in gradient-echo imaging, as they typically result from discontinuity in the magnetic susceptibility at air-tissue boundaries. Moreover, these induced gradients severely compromise the measurement of R*(2), the effective transverse relaxation rate, which is of interest in many biomedical applications of MRI. Since the slice thickness is usually larger than the in-plane pixel dimensions, gradients parallel to the slice-select direction are of particular concern. In this work, a post-processing technique is introduced which attempts to correct the signal on the assumption that the background gradients are approximately linear across the voxel and the signal decay in the absence of these gradients is exponential. In this case, the time-domain signal is weighted by a sinc function characterized by the amplitude G(b) of the background gradient, which is typically not known a priori. The algorithm searches for the estimate of G(b) which yields the optimum fit of the corrected experimental data to an exponential. It is shown to be effective as long as this gradient is below a critical threshold. Evaluation in a phantom and in the human brain at 1.5 and 4 T demonstrates that this method can restore R(2)* in spite of the apparent rate constant exceeding the true value by up to 100%. Contrary to prospective correction techniques, the approach presented in this study does not prolong scan time.

Entities:  

Mesh:

Year:  2000        PMID: 10975885     DOI: 10.1002/1522-2594(200009)44:3<358::aid-mrm3>3.0.co;2-i

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  39 in total

1.  R*(2) mapping in the presence of macroscopic B₀ field variations.

Authors:  Diego Hernando; Karl K Vigen; Ann Shimakawa; Scott B Reeder
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

2.  MODEL-BASED IMAGE RECONSTRUCTION FOR MRI.

Authors:  Jeffrey A Fessler
Journal:  IEEE Signal Process Mag       Date:  2010-07-01       Impact factor: 12.551

3.  Gradient echo plural contrast imaging--signal model and derived contrasts: T2*, T1, phase, SWI, T1f, FST2*and T2*-SWI.

Authors:  Jie Luo; Bharathi D Jagadeesan; Anne H Cross; Dmitriy A Yablonskiy
Journal:  Neuroimage       Date:  2012-01-28       Impact factor: 6.556

4.  T₂* mapping and B₀ orientation-dependence at 7 T reveal cyto- and myeloarchitecture organization of the human cortex.

Authors:  J Cohen-Adad; J R Polimeni; K G Helmer; T Benner; J A McNab; L L Wald; B R Rosen; C Mainero
Journal:  Neuroimage       Date:  2012-01-15       Impact factor: 6.556

Review 5.  The optimal use of contrast agents at high field MRI.

Authors:  Siegfried Trattnig; Kathia Pinker; Ahmed Ba-Ssalamah; Iris-Melanie Nöbauer-Huhmann
Journal:  Eur Radiol       Date:  2006-03-01       Impact factor: 5.315

6.  Signal decay correction in 2D ultra-short echo time imaging.

Authors:  Detlef Mentrup; Holger Eggers
Journal:  MAGMA       Date:  2006-05-09       Impact factor: 2.310

7.  Signal decay due to susceptibility-induced intravoxel dephasing on multiple air-filled cylinders: MRI simulations and experiments.

Authors:  François De Guio; Hugues Benoit-Cattin; Armel Davenel
Journal:  MAGMA       Date:  2008-06-25       Impact factor: 2.310

8.  Reproducibility of T2 * mapping in the human cerebral cortex in vivo at 7 tesla MRI.

Authors:  Sindhuja T Govindarajan; Julien Cohen-Adad; Maria Pia Sormani; Audrey P Fan; Céline Louapre; Caterina Mainero
Journal:  J Magn Reson Imaging       Date:  2014-11-19       Impact factor: 4.813

Review 9.  Quantification of liver iron with MRI: state of the art and remaining challenges.

Authors:  Diego Hernando; Yakir S Levin; Claude B Sirlin; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2014-03-03       Impact factor: 4.813

10.  Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

Authors:  Ralf B Loeffler; M Beth McCarville; Anne W Wagstaff; Matthew P Smeltzer; Axel J Krafft; Ruitian Song; Jane S Hankins; Claudia M Hillenbrand
Journal:  Pediatr Radiol       Date:  2016-10-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.