Literature DB >> 16149063

Convergence behavior of iterative SENSE reconstruction with non-Cartesian trajectories.

Peng Qu1, Kai Zhong, Bida Zhang, Jianmin Wang, Gary X Shen.   

Abstract

In non-Cartesian SENSE reconstruction based on the conjugate gradient (CG) iteration method, the iteration very often exhibits a "semi-convergence" behavior, which can be characterized as initial convergence toward the exact solution and later divergence. This phenomenon causes difficulties in automatic implementation of this reconstruction strategy. In this study, the convergence behavior of the iterative SENSE reconstruction is analyzed based on the mathematical principle of the CG method. It is revealed that the semi-convergence behavior is caused by the ill-conditioning of the underlying generalized encoding matrix (GEM) and the intrinsic regularization effect of CG iteration. From the perspective of regularization, each iteration vector is a regularized solution and the number of iterations plays the role of the regularization parameter. Therefore, the iteration count controls the compromise between the SNR and the residual aliasing artifact. Based on this theory, suggestions with respect to the stopping rule for well-behaved reconstructions are provided. Simulated radial imaging and in vivo spiral imaging are performed to demonstrate the theoretical analysis on the semi-convergence phenomenon and the stopping criterion. The dependence of convergence behavior on the undersampling rate and the noise level in samples is also qualitatively investigated. Copyright 2005 Wiley-Liss, Inc.

Mesh:

Year:  2005        PMID: 16149063     DOI: 10.1002/mrm.20648

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  MODEL-BASED IMAGE RECONSTRUCTION FOR MRI.

Authors:  Jeffrey A Fessler
Journal:  IEEE Signal Process Mag       Date:  2010-07-01       Impact factor: 12.551

2.  Signal decay correction in 2D ultra-short echo time imaging.

Authors:  Detlef Mentrup; Holger Eggers
Journal:  MAGMA       Date:  2006-05-09       Impact factor: 2.310

3.  Fast parallel spiral chemical shift imaging at 3T using iterative SENSE reconstruction.

Authors:  Dirk Mayer; Dong-Hyun Kim; Daniel M Spielman; Roland Bammer
Journal:  Magn Reson Med       Date:  2008-04       Impact factor: 4.668

Review 4.  Non-Cartesian parallel imaging reconstruction.

Authors:  Katherine L Wright; Jesse I Hamilton; Mark A Griswold; Vikas Gulani; Nicole Seiberlich
Journal:  J Magn Reson Imaging       Date:  2014-01-10       Impact factor: 4.813

5.  Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: application to cardiac cine.

Authors:  Shu Li; Cheong Chan; Jason P Stockmann; Hemant Tagare; Ganesh Adluru; Leo K Tam; Gigi Galiana; R Todd Constable; Sebastian Kozerke; Dana C Peters
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

6.  On-the-Fly Adaptive ${k}$ -Space Sampling for Linear MRI Reconstruction Using Moment-Based Spectral Analysis.

Authors:  Evan Levine; Brian Hargreaves
Journal:  IEEE Trans Med Imaging       Date:  2018-02       Impact factor: 10.048

7.  Novel 16-channel receive coil array for accelerated upper airway MRI at 3 Tesla.

Authors:  Yoon-Chul Kim; Cecil E Hayes; Shrikanth S Narayanan; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2010-12-16       Impact factor: 4.668

8.  Accelerated whole-heart coronary MRA using motion-corrected sensitivity encoding with three-dimensional projection reconstruction.

Authors:  Jianing Pang; Behzad Sharif; Reza Arsanjani; Xiaoming Bi; Zhaoyang Fan; Qi Yang; Kuncheng Li; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

9.  Comparison of parallel MRI reconstruction methods for accelerated 3D fast spin-echo imaging.

Authors:  Zhikui Xiao; W Scott Hoge; R V Mulkern; Lei Zhao; Guangshu Hu; Walid E Kyriakos
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

10.  Efficient spiral in-out and EPI balanced steady-state free precession cine imaging using a high-performance 0.55T MRI.

Authors:  Matthew C Restivo; Rajiv Ramasawmy; W Patricia Bandettini; Daniel A Herzka; Adrienne E Campbell-Washburn
Journal:  Magn Reson Med       Date:  2020-04-14       Impact factor: 3.737

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.