Literature DB >> 18222870

A homogeneity correction method for magnetic resonance imaging with time-varying gradients.

D C Noll1, C H Meyer, J M Pauly, D G Nishimura, A Macovski.   

Abstract

When time-varying gradients are used for imaging, the off-resonance behavior does not just cause geometric distortion as is the case with spin-warp imaging, but changes the shape of the impulse response and causes blurring. This effect is well known for projection reconstruction and spiral k-space scanning sequences. The authors introduce a reconstruction and homogeneity correction method to correct for the zeroth order effects of inhomogeneity using prior knowledge of the inhomogeneity. In this method, the data are segmented according to collection time, reconstructed using some fast, linear algorithm, correlated for inhomogeneity, and then superimposed to yield a homogeneity corrected image. This segmented method is compared to a conjugate phase reconstruction in terms of degree of correction and execution time. The authors apply this method to in vivo images using projection-reconstruction and spiral-scan sequences.

Year:  1991        PMID: 18222870     DOI: 10.1109/42.108599

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  64 in total

Review 1.  Sources of distortion in functional MRI data.

Authors:  P Jezzard; S Clare
Journal:  Hum Brain Mapp       Date:  1999       Impact factor: 5.038

2.  Three-dimensional tailored RF pulses for the reduction of susceptibility artifacts in T(*)(2)-weighted functional MRI.

Authors:  V A Stenger; F E Boada; D C Noll
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

3.  Multishot 3D slice-select tailored RF pulses for MRI.

Authors:  V Andrew Stenger; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

4.  On spatially selective RF excitation and its analogy with spiral MR image acquisition.

Authors:  P Börnert; B Aldefeld
Journal:  MAGMA       Date:  1998-12       Impact factor: 2.310

5.  Resting-state synchrony in long-term abstinent alcoholics.

Authors:  Jazmin Camchong; Andy Stenger; George Fein
Journal:  Alcohol Clin Exp Res       Date:  2012-06-22       Impact factor: 3.455

6.  Nonrigid motion correction in 3D using autofocusing with localized linear translations.

Authors:  Joseph Y Cheng; Marcus T Alley; Charles H Cunningham; Shreyas S Vasanawala; John M Pauly; Michael Lustig
Journal:  Magn Reson Med       Date:  2012-02-03       Impact factor: 4.668

7.  NonCartesian MR image reconstruction with integrated gradient nonlinearity correction.

Authors:  Shengzhen Tao; Joshua D Trzasko; Yunhong Shu; John Huston; Kevin M Johnson; Paul T Weavers; Erin M Gray; Matt A Bernstein
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

8.  Improvements in spiral MR imaging.

Authors:  P Börnert; H Schomberg; B Aldefeld; J Groen
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

Review 9.  Current trends and challenges in MRI acquisitions to investigate brain function.

Authors:  Bradley P Sutton; Cheng Ouyang; Dimitrios C Karampinos; Gregory A Miller
Journal:  Int J Psychophysiol       Date:  2009-02-21       Impact factor: 2.997

10.  Improved encoding pulses for Bloch-Siegert B1(+) mapping.

Authors:  Marcin Jankiewicz; John C Gore; William A Grissom
Journal:  J Magn Reson       Date:  2012-11-17       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.