Literature DB >> 16763931

A study of grid artifacts formation and elimination in computed radiographic images.

Chih-Yang Lin1, Wen-Jeng Lee, Shyh-Jye Chen, Ching-Hwa Tsai, Jei-Han Lee, Chia-Hung Chang, Yu-Tai Ching.   

Abstract

Computed radiography (CR) has many advantages such as filmless operations, efficiency, and convenience. Furthermore, it is easier to integrate with the picture archiving and communication systems. Another important advantage is that CR images generally have a wider dynamic range than conventional screen film. Unfortunately, grid artifacts and moiré pattern artifacts may be present in CR images. These artifacts become a more serious problem when viewing CR images on a computer monitor when a clinic grade monitor is not available. Images produced using a grid with higher frequency or a Potter--Bucky grid (i.e., a moving grid, Bucky for short) can reduce occurrence but cannot guarantee elimination of these artifacts [CR & PACS (2000); Detrick F (2001), pp 7-8]. In this paper, the formation of the artifacts is studied. We show that the grid artifacts occur in a narrow band of frequency in the frequency domain. The frequency can be determined, accurately located, and thus removed from the frequency domain. When comparing the results obtained from the proposed method against the results obtained using previous computer methods, we show that our method can achieve better image quality.

Entities:  

Mesh:

Year:  2006        PMID: 16763931      PMCID: PMC3045157          DOI: 10.1007/s10278-006-0630-8

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  7 in total

Review 1.  Principles of digital radiography with large-area, electronically readable detectors: a review of the basics.

Authors:  H G Chotas; J T Dobbins; C E Ravin
Journal:  Radiology       Date:  1999-03       Impact factor: 11.105

Review 2.  Artefacts found in computed radiography.

Authors:  L J Cesar; B A Schueler; F E Zink; T R Daly; J P Taubel; L L Jorgenson
Journal:  Br J Radiol       Date:  2001-02       Impact factor: 3.039

3.  The evolution of display technologies in PACS applications.

Authors:  Minglin Li; David Wilson; Michael Wong; Albert Xthona
Journal:  Comput Med Imaging Graph       Date:  2003       Impact factor: 4.790

Review 4.  The physics of computed radiography.

Authors:  J A Rowlands
Journal:  Phys Med Biol       Date:  2002-12-07       Impact factor: 3.609

5.  Comparing image quality of flat-panel chest radiography with storage phosphor radiography and film-screen radiography.

Authors:  Marika Ganten; Boris Radeleff; Annette Kampschulte; Mark D Daniels; Günter W Kauffmann; Jochen Hansmann
Journal:  AJR Am J Roentgenol       Date:  2003-07       Impact factor: 3.959

6.  Digital radiography of the chest: detector techniques and performance parameters.

Authors:  Cornelia Schaefer-Prokop; Martin Uffmann; Edith Eisenhuber; Mathias Prokop
Journal:  J Thorac Imaging       Date:  2003-07       Impact factor: 3.000

7.  Film digitization aliasing artifacts caused by grid line patterns.

Authors:  J Wang; H K Huang
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

  7 in total
  7 in total

1.  A new stationary gridline artifact suppression method based on the 2D discrete wavelet transform.

Authors:  Hui Tang; Dan Tong; Xu Dong Bao; Jean-Louis Dillenseger
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

2.  Evaluation of the microangiographic fluoroscope (MAF) using generalized system performance metrics.

Authors:  Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

3.  Design and evaluation of a grid reciprocation scheme for use in digital breast tomosynthesis.

Authors:  Tushita Patel; Helen Sporkin; Heather Peppard; Mark B Williams
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-29

4.  Transmission characteristics of a two dimensional antiscatter grid prototype for CBCT.

Authors:  Cem Altunbas; Brian Kavanagh; Timur Alexeev; Moyed Miften
Journal:  Med Phys       Date:  2017-06-16       Impact factor: 4.071

5.  Limitations of anti-scatter grids when used with high resolution image detectors.

Authors:  V Singh; A Jain; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19

6.  Patch Based Grid Artifact Suppressing in Digital Mammography.

Authors:  Qingqing Ling; Shuyu Wu; Xiaoman Duan; Genggeng Qin; Jianhui Ma; Chaomin Chen; Hongliang Qi; Linghong Zhou; Yuan Xu
Journal:  Biomed Res Int       Date:  2018-08-12       Impact factor: 3.411

7.  Run length encoding based wavelet features for COVID-19 detection in X-rays.

Authors:  Ahmad Sarhan
Journal:  BJR Open       Date:  2021-02-02
  7 in total