Literature DB >> 12818852

Comparing image quality of flat-panel chest radiography with storage phosphor radiography and film-screen radiography.

Marika Ganten1, Boris Radeleff, Annette Kampschulte, Mark D Daniels, Günter W Kauffmann, Jochen Hansmann.   

Abstract

OBJECTIVE: To evaluate image quality of a large-area direct-readout flat-panel detector system in chest radiography, we conducted an observer preference study. A clinical comparative study was conducted of the flat-panel system versus the storage phosphor and standard film-screen systems.
MATERIALS AND METHODS: Routine chest radiographs (posteroanterior) of 30 patients that were obtained using flat-panel, storage phosphor, and film screen systems were compared. The visibility of 10 anatomic regions and the overall image quality criteria were rated independently by three radiologists using a 5-point scale. The significance of the differences in diagnostic performance was tested with a Wilcoxon's signed rank test. Dose measurements for the three modalities were performed.
RESULTS: The flat-panel radiography system showed an improved visibility in most anatomic structures when compared with a state-of-the-art conventional film-screen system and an equal visibility when compared with a storage phosphor system. The flat-panel system showed the greatest enhancement in the depiction of small detailed structures (p < 0.05) and achieved this with a reduction in overall radiation dose of more than 50%.
CONCLUSION: The visibility of anatomic structures provided by this flat-panel detector system is as good as if not better than that provided by conventional or storage phosphor systems while emitting a reduced radiation dose.

Entities:  

Mesh:

Year:  2003        PMID: 12818852     DOI: 10.2214/ajr.181.1.1810171

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  A study of grid artifacts formation and elimination in computed radiographic images.

Authors:  Chih-Yang Lin; Wen-Jeng Lee; Shyh-Jye Chen; Ching-Hwa Tsai; Jei-Han Lee; Chia-Hung Chang; Yu-Tai Ching
Journal:  J Digit Imaging       Date:  2006-12       Impact factor: 4.056

2.  Intramodality and intermodality comparisons of storage phosphor computed radiography and conventional film-screen radiography in the recognition of small pneumoconiotic opacities.

Authors:  A Scott Laney; Edward L Petsonk; Michael D Attfield
Journal:  Chest       Date:  2011-05-26       Impact factor: 9.410

3.  Development of standard digital images for pneumoconiosis.

Authors:  Won-Jeong Lee; Byung-Soon Choi; Sung Jin Kim; Choong-Ki Park; Jai-Soung Park; Seok Tae; Kurt Georg Hering
Journal:  J Korean Med Sci       Date:  2011-10-27       Impact factor: 2.153

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.