Literature DB >> 16518653

High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography--initial experience.

Carsten Rist1, Konstantin Nikolaou, Thomas Flohr, Bernd J Wintersperger, Maximilian F Reiser, Christoph R Becker.   

Abstract

The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265+/-25HU and 254+/-16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367+/-36HU versus 402+/-28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68+/-0.08 mm versus 2.81+/-0.07 mm and 3.29+/-0.06 mm versus 3.18+/-0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen.

Entities:  

Mesh:

Year:  2006        PMID: 16518653     DOI: 10.1007/s00330-006-0186-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  13 in total

1.  Coronary artery stents in multislice computed tomography: in vitro artifact evaluation.

Authors:  Andreas H Mahnken; Arno Buecker; Joachim E Wildberger; Alexander Ruebben; Sven Stanzel; Felix Vogt; Rolf W Günther; Rüdiger Blindt
Journal:  Invest Radiol       Date:  2004-01       Impact factor: 6.016

Review 2.  Performance evaluation of a 64-slice CT system with z-flying focal spot.

Authors:  T Flohr; K Stierstorfer; R Raupach; S Ulzheimer; H Bruder
Journal:  Rofo       Date:  2004-12

3.  Noninvasive assessment of left main coronary stent patency with 16-slice computed tomography.

Authors:  Martine Gilard; Jean Christophe Cornily; Gilles Rioufol; Gerard Finet; Pierre Yves Pennec; Jacques Mansourati; Jean Jacques Blanc; Jacques Boschat
Journal:  Am J Cardiol       Date:  2005-01-01       Impact factor: 2.778

4.  Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter.

Authors:  Harald Seifarth; Rainer Raupach; Stefan Schaller; Eva Maria Fallenberg; Thomas Flohr; Walter Heindel; Roman Fischbach; David Maintz
Journal:  Eur Radiol       Date:  2005-02-12       Impact factor: 5.315

5.  Flat-panel detector computed tomography for the assessment of coronary artery stents: phantom study in comparison with 16-slice spiral computed tomography.

Authors:  Andreas H Mahnken; Tobias Seyfarth; Thomas Flohr; Christopher Herzog; Jochen Stahl; Sven Stanzel; Axel Kuettner; Joachim E Wildberger; Rolf W Günther
Journal:  Invest Radiol       Date:  2005-01       Impact factor: 6.016

6.  Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries.

Authors:  Jeffrey J Popma; Martin B Leon; Jeffrey W Moses; David R Holmes; Nicholas Cox; Michelle Fitzpatrick; John Douglas; Charles Lambert; Michael Mooney; Steven Yakubov; Richard E Kuntz
Journal:  Circulation       Date:  2004-12-13       Impact factor: 29.690

7.  Feasibility of assessment of coronary stent patency using 16-slice computed tomography.

Authors:  Joanne D Schuijf; Jeroen J Bax; J Wouter Jukema; Hildo J Lamb; Hazem M A Warda; Hubert W Vliegen; Albert de Roos; Ernst E van der Wall
Journal:  Am J Cardiol       Date:  2004-08-15       Impact factor: 2.778

8.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

9.  Noninvasive evaluation of coronary artery stents patency after PTCA: role of Multislice Computed Tomography.

Authors:  Guido Ligabue; Rosario Rossi; Carlo Ratti; Marco Favali; Maria Grazia Modena; Renato Romagnoli
Journal:  Radiol Med       Date:  2004 Jul-Aug       Impact factor: 3.469

10.  Assessment of coronary arterial stents by multislice-CT angiography.

Authors:  D Maintz; M Grude; E M Fallenberg; W Heindel; R Fischbach
Journal:  Acta Radiol       Date:  2003-11       Impact factor: 1.701

View more
  5 in total

1.  Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography.

Authors:  Tiziano Schepis; Pascal Koepfli; Sebastian Leschka; Lotus Desbiolles; Lars Husmann; Oliver Gaemperli; Franz R Eberli; Simon Wildermuth; Borut Marincek; Thomas F Lüscher; Hatem Alkadhi; Philipp A Kaufmann
Journal:  Eur Radiol       Date:  2007-01-06       Impact factor: 5.315

2.  Accuracy of dual-source computed tomography in quantitative assessment of low density coronary stenosis--a motion phantom study.

Authors:  Michael Toepker; Christopher L Schlett; Thomas Irlbeck; Amir A Mahabadi; Fabian Bamberg; Christiane Leidecker; Patrick Donnelly; Udo Hoffmann
Journal:  Eur Radiol       Date:  2009-09-02       Impact factor: 5.315

3.  A new approach to the assessment of lumen visibility of coronary artery stent at various heart rates using 64-slice MDCT.

Authors:  J M Groen; M J W Greuter; P M A van Ooijen; M Oudkerk
Journal:  Eur Radiol       Date:  2007-02-16       Impact factor: 5.315

4.  Coronary artery calcium and risk of atrial fibrillation (from the multi-ethnic study of atherosclerosis).

Authors:  Wesley T O'Neal; Jimmy T Efird; Farah Z Dawood; Joseph Yeboah; Alvaro Alonso; Susan R Heckbert; Elsayed Z Soliman
Journal:  Am J Cardiol       Date:  2014-09-16       Impact factor: 2.778

5.  Coronary artery stent evaluation using a vascular model at 64-detector row CT: comparison between prospective and retrospective ECG-gated axial scans.

Authors:  Shigeru Suzuki; Shigeru Furui; Sadatoshi Kuwahara; Dhruv Mehta; Tatsuro Kaminaga; Akiyoshi Miyazawa; Yasunari Ueno; Kumiko Konno
Journal:  Korean J Radiol       Date:  2009-04-22       Impact factor: 3.500

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.