Literature DB >> 17206429

Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography.

Tiziano Schepis1, Pascal Koepfli, Sebastian Leschka, Lotus Desbiolles, Lars Husmann, Oliver Gaemperli, Franz R Eberli, Simon Wildermuth, Borut Marincek, Thomas F Lüscher, Hatem Alkadhi, Philipp A Kaufmann.   

Abstract

We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 +/- 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer's values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 +/- 0.39 mm versus 2.49 +/- 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 +/- 6.2 mm, correlating well with CT (18.5 +/- 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 +/- 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA.

Entities:  

Mesh:

Year:  2007        PMID: 17206429     DOI: 10.1007/s00330-006-0502-0

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  30 in total

1.  Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter.

Authors:  Harald Seifarth; Rainer Raupach; Stefan Schaller; Eva Maria Fallenberg; Thomas Flohr; Walter Heindel; Roman Fischbach; David Maintz
Journal:  Eur Radiol       Date:  2005-02-12       Impact factor: 5.315

2.  64- Versus 16-slice CT angiography for coronary artery stent assessment: in vitro experience.

Authors:  Harald Seifarth; Murat Ozgün; Rainer Raupach; Thomas Flohr; Walter Heindel; Roman Fischbach; David Maintz
Journal:  Invest Radiol       Date:  2006-01       Impact factor: 6.016

3.  An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-06       Impact factor: 2.571

4.  Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries.

Authors:  Joelle M Kefer; Emmanuel Coche; Jean-Louis J Vanoverschelde; Bernhard L Gerber
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents.

Authors:  David Maintz; Harald Seifarth; Rainer Raupach; Thomas Flohr; Michael Rink; Torsten Sommer; Murat Ozgün; Walter Heindel; Roman Fischbach
Journal:  Eur Radiol       Date:  2005-12-07       Impact factor: 5.315

7.  Assessment of coronary artery stents by 16 slice computed tomography.

Authors:  M Gilard; J C Cornily; P Y Pennec; G Le Gal; M Nonent; J Mansourati; J J Blanc; J Boschat
Journal:  Heart       Date:  2005-04-21       Impact factor: 5.994

8.  Feasibility of assessment of coronary stent patency using 16-slice computed tomography.

Authors:  Joanne D Schuijf; Jeroen J Bax; J Wouter Jukema; Hildo J Lamb; Hazem M A Warda; Hubert W Vliegen; Albert de Roos; Ernst E van der Wall
Journal:  Am J Cardiol       Date:  2004-08-15       Impact factor: 2.778

9.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

10.  Assessment of coronary arterial stents by multislice-CT angiography.

Authors:  D Maintz; M Grude; E M Fallenberg; W Heindel; R Fischbach
Journal:  Acta Radiol       Date:  2003-11       Impact factor: 1.701

View more
  6 in total

1.  Non-invasive evaluation of coronary artery stent patency with retrospectively ECG-gated 64-slice CT angiography.

Authors:  Iacopo Carbone; Marco Francone; Emanuela Algeri; Antonino Granatelli; Alessandro Napoli; Miles A Kirchin; Carlo Catalano; Roberto Passariello
Journal:  Eur Radiol       Date:  2007-10-10       Impact factor: 5.315

2.  First in vivo head-to-head comparison of high-definition versus standard-definition stent imaging with 64-slice computed tomography.

Authors:  Tobias A Fuchs; Julia Stehli; Michael Fiechter; Svetlana Dougoud; Bert-Ram Sah; Cathérine Gebhard; Sacha Bull; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2013-05-01       Impact factor: 2.357

3.  Assessment of in-stent restenosis using 64-MDCT: analysis of the CORE-64 Multicenter International Trial.

Authors:  Joanna J Wykrzykowska; Armin Arbab-Zadeh; Gustavo Godoy; Julie M Miller; Shezhang Lin; Andrea Vavere; Narinder Paul; Hiroyuki Niinuma; John Hoe; Jeffrey Brinker; Faisal Khosa; Sheryar Sarwar; Joao Lima; Melvin E Clouse
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

4.  Stent evaluation by coronary computed tomography angiography: a comparison between Iopamidol-370 and Ioversol-320 hypo-osmolar iodine concentration contrasts.

Authors:  Annelisa Moura Garcia; Antonildes N Assunção-Jr; Roberto Nery Dantas-Jr; Jose Rodrigues Parga; Fernando Ganem
Journal:  Br J Radiol       Date:  2020-08-20       Impact factor: 3.039

5.  Diagnostic accuracy of in-stent coronary restenosis detection with multislice spiral computed tomography: a meta-analysis.

Authors:  Michèle Hamon; Laure Champ-Rigot; Rémy Morello; John W Riddell; Martial Hamon
Journal:  Eur Radiol       Date:  2007-09-01       Impact factor: 5.315

6.  Performance of dual-source CT with high pitch spiral mode for coronary stent patency compared with invasive coronary angiography.

Authors:  Xia Yang; Qiang Yu; Wei Dong; Zhen-Hong Fu; Jun-Jue Yang; Jun Guo; Yun-Dai Chen
Journal:  J Geriatr Cardiol       Date:  2016-10       Impact factor: 3.327

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.