Literature DB >> 15325923

Feasibility of assessment of coronary stent patency using 16-slice computed tomography.

Joanne D Schuijf1, Jeroen J Bax, J Wouter Jukema, Hildo J Lamb, Hazem M A Warda, Hubert W Vliegen, Albert de Roos, Ernst E van der Wall.   

Abstract

Intracoronary stent implantation is a frequently performed procedure in the treatment of stenoses in coronary arteries, but in-stent restenosis occurs in approximately 10% to 15% of patients. A noninvasive diagnostic procedure to evaluate in-stent restenosis would therefore be of great benefit. We investigated the feasibility of assessing stent patency with 16-slice computed tomography. Multislice computed tomography (MSCT) was performed in 22 patients with previously implanted stents. For each stent, assessability was determined and related to stent type and diameter. Subsequently, the presence of significant restenosis was determined in the evaluable stents. In addition, peristent lumina (5 mm proximal and distal to the stent) were evaluated. Conventional angiography in combination with quantitative coronary angiography served as the standard of reference. MSCT was performed successfully in all but 1 patient. Of 65 stents, 50 (77%) were determined assessable. Uninterpretable stents tended to have a thicker strut and/or a smaller diameter. In the evaluable stents, 7 of 9 stenoses were detected and the absence of restenosis was correctly identified in all 41 patent stents, resulting in a sensitivity and specificity of 78% and 100%, respectively. Sensitivity and specificity for the detection of peristent stenosis were 75% and 96%, respectively. In conclusion, MSCT may be useful in the assessment of stent patency and may function as a gatekeeper before invasive diagnostic procedures.

Entities:  

Mesh:

Year:  2004        PMID: 15325923     DOI: 10.1016/j.amjcard.2004.04.057

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  33 in total

1.  [Imaging of coronary stents using multislice computed tomography].

Authors:  H Seifarth; W Heindel; D Maintz
Journal:  Radiologe       Date:  2010-06       Impact factor: 0.635

2.  Computed tomographic imaging within nuclear cardiology.

Authors: 
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

Review 3.  Multislice CT coronary angiography: how to do it and what is the current clinical performance?

Authors:  Filippo Cademartiri; Joanne D Schuijf; Nico R Mollet; Patrizia Malagutti; Giuseppe Runza; Jeroen J Bax; Pim J de Feyter
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-11       Impact factor: 9.236

4.  Evaluation of in-stent restenosis in proximal coronary arteries with multidetector computed tomography (MDCT).

Authors:  V Chabbert; D Carrie; M Bennaceur; E Maupas; V Lauwers; M Mhem; T Lhermusier; M Elbaz; F Joffre; H Rousseau; J Puel
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

Review 5.  Cardiac CT: coronary arteries and beyond.

Authors:  Andreas H Mahnken; Georg Mühlenbruch; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2006-10-26       Impact factor: 5.315

6.  Use of high-resolution spiral CT for the diagnosis of coronary artery disease.

Authors:  Willem B Meijboom; Niels van Pelt; Pim de Feyter
Journal:  Curr Treat Options Cardiovasc Med       Date:  2007-02

Review 7.  The current status of multislice computed tomography in the diagnosis and prognosis of coronary artery disease.

Authors:  Joanne D Schuijf; J Wouter Jukema; Ernest E van der Wall; Jeroen J Bax
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

8.  Coronary artery stent geometry and in-stent contrast attenuation with 64-slice computed tomography.

Authors:  Tiziano Schepis; Pascal Koepfli; Sebastian Leschka; Lotus Desbiolles; Lars Husmann; Oliver Gaemperli; Franz R Eberli; Simon Wildermuth; Borut Marincek; Thomas F Lüscher; Hatem Alkadhi; Philipp A Kaufmann
Journal:  Eur Radiol       Date:  2007-01-06       Impact factor: 5.315

9.  Diagnostic accuracy of in-stent coronary restenosis detection with multislice spiral computed tomography: a meta-analysis.

Authors:  Michèle Hamon; Laure Champ-Rigot; Rémy Morello; John W Riddell; Martial Hamon
Journal:  Eur Radiol       Date:  2007-09-01       Impact factor: 5.315

10.  Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64.

Authors:  Julie M Miller; Marc Dewey; Andrea L Vavere; Carlos E Rochitte; Hiroyuki Niinuma; Armin Arbab-Zadeh; Narinder Paul; John Hoe; Albert de Roos; Kunihiro Yoshioka; Pedro A Lemos; David E Bush; Albert C Lardo; John Texter; Jeffery Brinker; Christopher Cox; Melvin E Clouse; João A C Lima
Journal:  Eur Radiol       Date:  2008-11-08       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.