Literature DB >> 16503158

Theoretical and experimental evaluation of the low m/z transmission of an electrodynamic ion funnel.

Jason S Page1, Aleksey V Tolmachev1, Keqi Tang1, Richard D Smith1.   

Abstract

The transmission of ions at low m/z can often be either necessary for an application or problematic (e.g., when large numbers of low m/z ions consume a large fraction of an ion trap's capacity). The low m/z ion transmission limit of an electrodynamic ion funnel has been characterized using both experimental and theoretical approaches. A theoretical model is developed based on a series of infinite wire conductors that represent the ring electrodes of the ion funnel. Mathematical relationships for both low and high m/z cutoffs of the idealized two-dimensional system are derived. The low m/z cutoff is also evaluated through a series of experiments that show it is influenced by both the RF frequency and the DC electric field gradient. However, unlike multipole ion guides, there is no marked dependence of the low m/z cutoff on the RF amplitude, in agreement with theoretical results. With this new understanding, ion funnels can be designed and configured to better match the m/z range requirements for various applications.

Mesh:

Substances:

Year:  2006        PMID: 16503158      PMCID: PMC1829303          DOI: 10.1016/j.jasms.2005.12.013

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  13 in total

1.  Characterization of an improved electrodynamic ion funnel interface for electrospray ionization mass spectrometry.

Authors:  S A Shaffer; A Tolmachev; D C Prior; G A Anderson; H R Udseth; R D Smith
Journal:  Anal Chem       Date:  1999-08-01       Impact factor: 6.986

2.  Charge capacity limitations of radio frequency ion guides in their use for improved ion accumulation and trapping in mass spectrometry.

Authors:  A V Tolmachev; H R Udseth; R D Smith
Journal:  Anal Chem       Date:  2000-03-01       Impact factor: 6.986

3.  Design and implementation of a new electrodynamic ion funnel.

Authors:  T Kim; A V Tolmachev; R Harkewicz; D C Prior; G Anderson; H R Udseth; R D Smith
Journal:  Anal Chem       Date:  2000-05-15       Impact factor: 6.986

4.  Characterizing the transmission properties of an ion funnel.

Authors:  E C Lynn; M C Chung; C C Han
Journal:  Rapid Commun Mass Spectrom       Date:  2000       Impact factor: 2.419

5.  A multicapillary inlet jet disruption electrodynamic ion funnel interface for improved sensitivity using atmospheric pressure ion sources.

Authors:  T Kim; K Tang; H R Udseth; R D Smith
Journal:  Anal Chem       Date:  2001-09-01       Impact factor: 6.986

Review 6.  Practical implications of some recent studies in electrospray ionization fundamentals.

Authors:  N B Cech; C G Enke
Journal:  Mass Spectrom Rev       Date:  2001 Nov-Dec       Impact factor: 10.946

7.  Independent control of ion transmission in a jet disrupter dual-channel ion funnel electrospray ionization MS interface.

Authors:  Keqi Tang; Aleksey V Tolmachev; Evgueni Nikolaev; Rui Zhang; Mikhail E Belov; Harold R Udseth; Richard D Smith
Journal:  Anal Chem       Date:  2002-10-15       Impact factor: 6.986

8.  Applications of a travelling wave-based radio-frequency-only stacked ring ion guide.

Authors:  Kevin Giles; Steven D Pringle; Kenneth R Worthington; David Little; Jason L Wildgoose; Robert H Bateman
Journal:  Rapid Commun Mass Spectrom       Date:  2004       Impact factor: 2.419

9.  High-sensitivity ion mobility spectrometry/mass spectrometry using electrodynamic ion funnel interfaces.

Authors:  Keqi Tang; Alexandre A Shvartsburg; Hak-No Lee; David C Prior; Michael A Buschbach; Fumin Li; Aleksey V Tolmachev; Gordon A Anderson; Richard D Smith
Journal:  Anal Chem       Date:  2005-05-15       Impact factor: 6.986

10.  Automatic gain control in mass spectrometry using a jet disrupter electrode in an electrodynamic ion funnel.

Authors:  Jason S Page; Bogdan Bogdanov; Andrey N Vilkov; David C Prior; Michael A Buschbach; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-02       Impact factor: 3.109

View more
  15 in total

1.  Numerical analysis of ion-funnel transmission efficiency in an API-MS system with a continuum/microscopic approach.

Authors:  Sergey Gimelshein; Taylor Lilly; Eugene Moskovets
Journal:  J Am Soc Mass Spectrom       Date:  2015-08-05       Impact factor: 3.109

2.  Capillary-based multi nanoelectrospray emitters: improvements in ion transmission efficiency and implementation with capillary reversed-phase LC-ESI-MS.

Authors:  Ryan T Kelly; Jason S Page; Rui Zhao; Wei-Jun Qian; Heather M Mottaz; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2007-11-29       Impact factor: 6.986

3.  Subambient pressure ionization with nanoelectrospray source and interface for improved sensitivity in mass spectrometry.

Authors:  Jason S Page; Keqi Tang; Ryan T Kelly; Richard D Smith
Journal:  Anal Chem       Date:  2008-02-01       Impact factor: 6.986

4.  Ion funnel trap interface for orthogonal time-of-flight mass spectrometry.

Authors:  Yehia Ibrahim; Mikhail E Belov; Aleksey V Tolmachev; David C Prior; Richard D Smith
Journal:  Anal Chem       Date:  2007-09-13       Impact factor: 6.986

5.  High Resolution Separations and Improved Ion Production and Transmission in Metabolomics.

Authors:  Thomas O Metz; Jason S Page; Erin S Baker; Keqi Tang; Jie Ding; Yufeng Shen; Richard D Smith
Journal:  Trends Analyt Chem       Date:  2008-03       Impact factor: 12.296

6.  The ion funnel: theory, implementations, and applications.

Authors:  Ryan T Kelly; Aleksey V Tolmachev; Jason S Page; Keqi Tang; Richard D Smith
Journal:  Mass Spectrom Rev       Date:  2010 Mar-Apr       Impact factor: 10.946

7.  Biases in ion transmission through an electrospray ionization-mass spectrometry capillary inlet.

Authors:  Jason S Page; Ioan Marginean; Erin S Baker; Ryan T Kelly; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2009-09-02       Impact factor: 3.109

8.  Achieving 50% ionization efficiency in subambient pressure ionization with nanoelectrospray.

Authors:  Ioan Marginean; Jason S Page; Aleksey V Tolmachev; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2010-10-28       Impact factor: 6.986

9.  Ionization and transmission efficiency in an electrospray ionization-mass spectrometry interface.

Authors:  Jason S Page; Ryan T Kelly; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2007-06-02       Impact factor: 3.109

10.  Characterization of macaque pulmonary fluid proteome during monkeypox infection: dynamics of host response.

Authors:  Joseph N Brown; Ryan D Estep; Daniel Lopez-Ferrer; Heather M Brewer; Theresa R Clauss; Nathan P Manes; Megan O'Connor; Helen Li; Joshua N Adkins; Scott W Wong; Richard D Smith
Journal:  Mol Cell Proteomics       Date:  2010-08-24       Impact factor: 5.911

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.