Literature DB >> 18237189

Subambient pressure ionization with nanoelectrospray source and interface for improved sensitivity in mass spectrometry.

Jason S Page1, Keqi Tang, Ryan T Kelly, Richard D Smith.   

Abstract

A nanoelectrospray ionization mass spectrometry (ESI-MS) source and interface has been designed that enables efficient ion production and transmission in a 30 Torr pressure environment using solvents compatible with typical reversed-phase liquid chromatography (RPLC) separations. In this design, the electrospray emitter is located inside the mass spectrometer in the same region as an electrodynamic ion funnel. This avoids the use of a conductance limiting ion inlet, as required by a conventional atmospheric pressure ESI source, and allows more efficient ion transmission to the mass analyzer. The new subambient pressure ionization with nanoelectrospray (SPIN) source improves instrument sensitivity and enables new electrospray interface designs, including the use of multi-emitter approaches. Performance of the SPIN source was evaluated by electrospraying standard solutions at 300 nL/min and comparing results with those obtained from a standard atmospheric pressure ESI source that used a heated capillary inlet. This initial study demonstrated an approximately 5-fold improvement in sensitivity when the SPIN source was used compared to a standard atmospheric pressure ESI source. The importance of desolvation was also investigated by electrospraying at different flow rates, which showed that the ion funnel provided an effective desolvation region to aid the creation of gas-phase analyte ions.

Entities:  

Mesh:

Year:  2008        PMID: 18237189      PMCID: PMC2516344          DOI: 10.1021/ac702354b

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  24 in total

1.  Characterization of an improved electrodynamic ion funnel interface for electrospray ionization mass spectrometry.

Authors:  S A Shaffer; A Tolmachev; D C Prior; G A Anderson; H R Udseth; R D Smith
Journal:  Anal Chem       Date:  1999-08-01       Impact factor: 6.986

2.  Characterizing the transmission properties of an ion funnel.

Authors:  E C Lynn; M C Chung; C C Han
Journal:  Rapid Commun Mass Spectrom       Date:  2000       Impact factor: 2.419

3.  Improved ion transmission from atmospheric pressure to high vacuum using a multicapillary inlet and electrodynamic ion funnel interface

Authors: 
Journal:  Anal Chem       Date:  2000-10-15       Impact factor: 6.986

Review 4.  Ultrasensitive and quantitative analyses from combined separations-mass spectrometry for the characterization of proteomes.

Authors:  Richard D Smith; Yufeng Shen; Keqi Tang
Journal:  Acc Chem Res       Date:  2004-04       Impact factor: 22.384

Review 5.  Advanced nanoscale separations and mass spectrometry for sensitive high-throughput proteomics.

Authors:  Yufeng Shen; Richard D Smith
Journal:  Expert Rev Proteomics       Date:  2005-06       Impact factor: 3.940

Review 6.  Advances and challenges in liquid chromatography-mass spectrometry-based proteomics profiling for clinical applications.

Authors:  Wei-Jun Qian; Jon M Jacobs; Tao Liu; David G Camp; Richard D Smith
Journal:  Mol Cell Proteomics       Date:  2006-08-03       Impact factor: 5.911

7.  Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface.

Authors:  Yehia Ibrahim; Keqi Tang; Aleksey V Tolmachev; Alexandre A Shvartsburg; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2006-07-12       Impact factor: 3.109

8.  Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry.

Authors:  Ryan T Kelly; Jason S Page; Quanzhou Luo; Ronald J Moore; Daniel J Orton; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2006-11-15       Impact factor: 6.986

9.  Analytical properties of the nanoelectrospray ion source.

Authors:  M Wilm; M Mann
Journal:  Anal Chem       Date:  1996-01-01       Impact factor: 6.986

10.  Automatic gain control in mass spectrometry using a jet disrupter electrode in an electrodynamic ion funnel.

Authors:  Jason S Page; Bogdan Bogdanov; Andrey N Vilkov; David C Prior; Michael A Buschbach; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2005-02       Impact factor: 3.109

View more
  33 in total

1.  A new approach to high sensitivity liquid chromatography-mass spectrometry of peptides using nanoflow solvent assisted inlet ionization.

Authors:  Beixi Wang; Ellen D Inutan; Sarah Trimpin
Journal:  J Am Soc Mass Spectrom       Date:  2012-01-12       Impact factor: 3.109

Review 2.  Molecular mass spectrometry imaging in biomedical and life science research.

Authors:  Jaroslav Pól; Martin Strohalm; Vladimír Havlíček; Michael Volný
Journal:  Histochem Cell Biol       Date:  2010-10-28       Impact factor: 4.304

3.  Improving liquid chromatography-mass spectrometry sensitivity using a subambient pressure ionization with nanoelectrospray (SPIN) interface.

Authors:  Keqi Tang; Jason S Page; Ioan Marginean; Ryan T Kelly; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2011-04-22       Impact factor: 3.109

Review 4.  New mass spectrometry technologies contributing towards comprehensive and high throughput omics analyses of single cells.

Authors:  Sneha P Couvillion; Ying Zhu; Gabe Nagy; Joshua N Adkins; Charles Ansong; Ryan S Renslow; Paul D Piehowski; Yehia M Ibrahim; Ryan T Kelly; Thomas O Metz
Journal:  Analyst       Date:  2019-01-28       Impact factor: 4.616

5.  DRILL: An Electrospray Ionization-Mass Spectrometry Interface for Improved Sensitivity via Inertial Droplet Sorting and Electrohydrodynamic Focusing in a Swirling Flow.

Authors:  Peter A Kottke; Jung Y Lee; Alex P Jonke; Chinthaka A Seneviratne; Elizabeth S Hecht; David C Muddiman; Matthew P Torres; Andrei G Fedorov
Journal:  Anal Chem       Date:  2017-06-29       Impact factor: 6.986

6.  Nanoelectrospray emitter arrays providing interemitter electric field uniformity.

Authors:  Ryan T Kelly; Jason S Page; Ioan Marginean; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2008-06-14       Impact factor: 6.986

7.  Effect of pressure on electrospray characteristics.

Authors:  Ioan Marginean; Jason S Page; Ryan T Kelly; Keqi Tang; Richard D Smith
Journal:  Appl Phys Lett       Date:  2009-11-06       Impact factor: 3.791

8.  On the ionization and ion transmission efficiencies of different ESI-MS interfaces.

Authors:  Jonathan T Cox; Ioan Marginean; Richard D Smith; Keqi Tang
Journal:  J Am Soc Mass Spectrom       Date:  2014-09-30       Impact factor: 3.109

9.  Protein quantitation through targeted mass spectrometry: the way out of biomarker purgatory?

Authors:  Steven A Carr; Leigh Anderson
Journal:  Clin Chem       Date:  2008-11       Impact factor: 8.327

10.  Analytical characterization of the electrospray ion source in the nanoflow regime.

Authors:  Ioan Marginean; Ryan T Kelly; David C Prior; Brian L LaMarche; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2008-07-29       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.