Literature DB >> 10845370

Design and implementation of a new electrodynamic ion funnel.

T Kim1, A V Tolmachev, R Harkewicz, D C Prior, G Anderson, H R Udseth, R D Smith.   

Abstract

A new electrodynamic (rf) ion funnel has been developed and evaluated for use in the interface regions (at approximately 1-10 Torr) of atmospheric pressure ion sources (e.g., electrospray ionization (ESI) for mass spectrometry). The ion funnel consists of a ring electrode ion guide with decreasing i.d. and with a superimposed dc potential gradient along the ring stack. The thicknesses of the ring electrodes and the spacings between them were reduced to 0.5 mm from 1.59 mm compared to those used for previous designs. The new ion funnel displays a significant improvement in low-mass transmission (m/z >200) and sensitivity compared to previous designs. The transmission efficiencies for electrosprayed peptides and proteins (ranging in mass from 200 to 17,000 Da) were typically 50-60% of total incoming currents from a heated capillary inlet. The transmitted ion currents were a factor of 30-56 greater than those of the standard interface for peptide samples and a factor of 18-22 greater than those for protein samples. The sensitivity gains realized at the MS detector were somewhat lower, possibly due to space charge effects in the octapole ion beam guide following the ion funnel. The improved ion transmission properties result primarily from the use of reduced spacings between ring electrodes. We also show that the ion funnel can be operated in two different modes, one using low-rf-amplitude scans, allowing fragile noncovalent complexes (as well as generally undesired adducts) to be transmitted, and the other using high-rf-amplitude scans, providing greater collisional activation and more effective adduct removal (or the dissociation of lower m/z species).

Entities:  

Mesh:

Year:  2000        PMID: 10845370     DOI: 10.1021/ac991412x

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  50 in total

1.  Frequency shifts due to the interference of resolved peaks in magnitude-mode Fourier-transform ion cyclotron resonance mass spectra.

Authors:  Aleksey V Tolmachev; Christophe D Masselon; Gordon A Anderson; Harold R Udseth; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2002-04       Impact factor: 3.109

2.  Direct mass spectrometric analysis of intact proteins of the yeast large ribosomal subunit using capillary LC/FTICR.

Authors:  Sang-Won Lee; Scott J Berger; Suzana Martinović; Ljiljana Pasa-Tolić; Gordon A Anderson; Yufeng Shen; Rui Zhao; Richard D Smith
Journal:  Proc Natl Acad Sci U S A       Date:  2002-04-30       Impact factor: 11.205

3.  ESI-FTICR mass spectrometry employing data-dependent external ion selection and accumulation.

Authors:  Richard Harkewicz; Mikhail E Belov; Gordon A Anderson; Ljiljana Pasa-Tolić; Christophe D Masselon; David C Prior; Harold R Udseth; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2002-02       Impact factor: 3.109

4.  Enhanced sensitivity for selected reaction monitoring mass spectrometry-based targeted proteomics using a dual stage electrodynamic ion funnel interface.

Authors:  Mahmud Hossain; David T Kaleta; Errol W Robinson; Tao Liu; Rui Zhao; Jason S Page; Ryan T Kelly; Ronald J Moore; Keqi Tang; David G Camp; Wei-Jun Qian; Richard D Smith
Journal:  Mol Cell Proteomics       Date:  2010-04-21       Impact factor: 5.911

5.  Thermodynamics and mechanisms of protonated diglycine decomposition: a guided ion beam study.

Authors:  P B Armentrout; Amy L Heaton
Journal:  J Am Soc Mass Spectrom       Date:  2011-08-17       Impact factor: 3.109

6.  Overtone mobility spectrometry: part 4. OMS-OMS analyses of complex mixtures.

Authors:  Ruwan T Kurulugama; Fabiane M Nachtigall; Stephen J Valentine; David E Clemmer
Journal:  J Am Soc Mass Spectrom       Date:  2011-08-09       Impact factor: 3.109

7.  Two-dimensional gas-phase separations coupled to mass spectrometry for analysis of complex mixtures.

Authors:  Keqi Tang; Fumin Li; Alexandre A Shvartsburg; Eric F Strittmatter; Richard D Smith
Journal:  Anal Chem       Date:  2005-10-01       Impact factor: 6.986

8.  High-sensitivity ion mobility spectrometry/mass spectrometry using electrodynamic ion funnel interfaces.

Authors:  Keqi Tang; Alexandre A Shvartsburg; Hak-No Lee; David C Prior; Michael A Buschbach; Fumin Li; Aleksey V Tolmachev; Gordon A Anderson; Richard D Smith
Journal:  Anal Chem       Date:  2005-05-15       Impact factor: 6.986

9.  Ion funnels for the masses: experiments and simulations with a simplified ion funnel.

Authors:  Ryan R Julian; Sarah R Mabbett; Martin F Jarrold
Journal:  J Am Soc Mass Spectrom       Date:  2005-10       Impact factor: 3.109

10.  An LC-IMS-MS platform providing increased dynamic range for high-throughput proteomic studies.

Authors:  Erin Shammel Baker; Eric A Livesay; Daniel J Orton; Ronald J Moore; William F Danielson; David C Prior; Yehia M Ibrahim; Brian L LaMarche; Anoop M Mayampurath; Athena A Schepmoes; Derek F Hopkins; Keqi Tang; Richard D Smith; Mikhail E Belov
Journal:  J Proteome Res       Date:  2010-02-05       Impact factor: 4.466

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.