Literature DB >> 17850113

Ion funnel trap interface for orthogonal time-of-flight mass spectrometry.

Yehia Ibrahim1, Mikhail E Belov, Aleksey V Tolmachev, David C Prior, Richard D Smith.   

Abstract

A combined electrodynamic ion funnel and ion trap coupled to an orthogonal acceleration (oa)-time-of-flight mass spectrometer was developed and characterized. The ion trap was incorporated through the use of added terminal electrodynamic ion funnel electrodes enabling control over the axial dc gradient in the trap section. The ion trap operates efficiently at a pressure of approximately 1 Torr, and measurements indicate a maximum charge capacity of approximately 3 x 10(7) charges. An order of magnitude increase in sensitivity was observed in the analysis of low concentration peptides mixtures with orthogonal acceleration (oa)-time-of-flight mass spectrometry (oa-TOF MS) in the trapping mode as compared to the continuous regime. A signal increase in the trapping mode was accompanied by reduction in the chemical background, due to more efficient desolvation of, for example, solvent related clusters. Controlling the ion trap ejection time was found to result in efficient removal of singly charged species and improving signal-to-noise ratio (S/N) for the multiply charged analytes.

Mesh:

Substances:

Year:  2007        PMID: 17850113      PMCID: PMC2516353          DOI: 10.1021/ac071091m

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  15 in total

Review 1.  Orthogonal acceleration time-of-flight mass spectrometry.

Authors:  M Guilhaus; D Selby; V Mlynski
Journal:  Mass Spectrom Rev       Date:  2000 Mar-Apr       Impact factor: 10.946

2.  Zeptomole-sensitivity electrospray ionization--Fourier transform ion cyclotron resonance mass spectrometry of proteins.

Authors:  M E Belov; M V Gorshkov; H R Udseth; G A Anderson; R D Smith
Journal:  Anal Chem       Date:  2000-05-15       Impact factor: 6.986

3.  Design and implementation of a new electrodynamic ion funnel.

Authors:  T Kim; A V Tolmachev; R Harkewicz; D C Prior; G Anderson; H R Udseth; R D Smith
Journal:  Anal Chem       Date:  2000-05-15       Impact factor: 6.986

4.  A combined linear ion trap time-of-flight system with improved performance and MS(n) capabilities.

Authors:  B A Collings; J M Campbell; D Mao; D J Douglas
Journal:  Rapid Commun Mass Spectrom       Date:  2001       Impact factor: 2.419

5.  A multicapillary inlet jet disruption electrodynamic ion funnel interface for improved sensitivity using atmospheric pressure ion sources.

Authors:  T Kim; K Tang; H R Udseth; R D Smith
Journal:  Anal Chem       Date:  2001-09-01       Impact factor: 6.986

6.  Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface.

Authors:  Yehia Ibrahim; Keqi Tang; Aleksey V Tolmachev; Alexandre A Shvartsburg; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2006-07-12       Impact factor: 3.109

7.  Peer Reviewed: Orthogonal-Injection TOFMS for Analyzing Biomolecules.

Authors:  I V Chernushevich; W Ens; K G Standing
Journal:  Anal Chem       Date:  1999-07       Impact factor: 6.986

8.  High sensitivity collisionally-activated decomposition tandem mass spectrometry on a novel quadrupole/orthogonal-acceleration time-of-flight mass spectrometer.

Authors:  H R Morris; T Paxton; A Dell; J Langhorne; M Berg; R S Bordoli; J Hoyes; R H Bateman
Journal:  Rapid Commun Mass Spectrom       Date:  1996       Impact factor: 2.419

9.  Reflecting time-of-flight mass spectrometer with an electrospray ion source and orthogonal extraction.

Authors:  A N Verentchikov; W Ens; K G Standing
Journal:  Anal Chem       Date:  1994-01-01       Impact factor: 6.986

10.  A new technique for decomposition of selected ions in molecule ion reactor coupled with ortho-time-of-flight mass spectrometry.

Authors:  A Dodonov; V Kozlovsky; A Loboda; V Raznikov; I Sulimenkov; A Tolmachev; A Kraft; H Wollnik
Journal:  Rapid Commun Mass Spectrom       Date:  1997       Impact factor: 2.419

View more
  44 in total

1.  Numerical analysis of ion-funnel transmission efficiency in an API-MS system with a continuum/microscopic approach.

Authors:  Sergey Gimelshein; Taylor Lilly; Eugene Moskovets
Journal:  J Am Soc Mass Spectrom       Date:  2015-08-05       Impact factor: 3.109

2.  Pseudorandom sequence modifications for ion mobility orthogonal time-of-flight mass spectrometry.

Authors:  Brian H Clowers; Mikhail E Belov; David C Prior; William F Danielson; Yehia Ibrahim; Richard D Smith
Journal:  Anal Chem       Date:  2008-03-01       Impact factor: 6.986

3.  Improving the efficiency of IMS-IMS by a combing technique.

Authors:  Samuel I Merenbloom; Stormy L Koeniger; Brian C Bohrer; Stephen J Valentine; David E Clemmer
Journal:  Anal Chem       Date:  2008-02-22       Impact factor: 6.986

4.  Enhanced ion utilization efficiency using an electrodynamic ion funnel trap as an injection mechanism for ion mobility spectrometry.

Authors:  Brian H Clowers; Yehia M Ibrahim; David C Prior; William F Danielson; Mikhail E Belov; Richard D Smith
Journal:  Anal Chem       Date:  2008-01-01       Impact factor: 6.986

5.  Development of an Ion Mobility Spectrometry-Orbitrap Mass Spectrometer Platform.

Authors:  Yehia M Ibrahim; Sandilya V B Garimella; Spencer A Prost; Roza Wojcik; Randolph V Norheim; Erin S Baker; Ivan Rusyn; Richard D Smith
Journal:  Anal Chem       Date:  2016-12-01       Impact factor: 6.986

6.  Dynamically multiplexed ion mobility time-of-flight mass spectrometry.

Authors:  Mikhail E Belov; Brian H Clowers; David C Prior; William F Danielson; Andrei V Liyu; Brianne O Petritis; Richard D Smith
Journal:  Anal Chem       Date:  2008-06-18       Impact factor: 6.986

7.  Automated gain control ion funnel trap for orthogonal time-of-flight mass spectrometry.

Authors:  Yehia M Ibrahim; Mikhail E Belov; Andrei V Liyu; Richard D Smith
Journal:  Anal Chem       Date:  2008-05-31       Impact factor: 6.986

8.  An LC-IMS-MS platform providing increased dynamic range for high-throughput proteomic studies.

Authors:  Erin Shammel Baker; Eric A Livesay; Daniel J Orton; Ronald J Moore; William F Danielson; David C Prior; Yehia M Ibrahim; Brian L LaMarche; Anoop M Mayampurath; Athena A Schepmoes; Derek F Hopkins; Keqi Tang; Richard D Smith; Mikhail E Belov
Journal:  J Proteome Res       Date:  2010-02-05       Impact factor: 4.466

9.  Mixed-isotope labeling with LC-IMS-MS for characterization of protein-protein interactions by chemical cross-linking.

Authors:  Eric D Merkley; Erin S Baker; Kevin L Crowell; Daniel J Orton; Thomas Taverner; Charles Ansong; Yehia M Ibrahim; Meagan C Burnet; John R Cort; Gordon A Anderson; Richard D Smith; Joshua N Adkins
Journal:  J Am Soc Mass Spectrom       Date:  2013-02-20       Impact factor: 3.109

10.  Ion manipulations in structures for lossless ion manipulations (SLIM): computational evaluation of a 90° turn and a switch.

Authors:  Sandilya V B Garimella; Yehia M Ibrahim; Ian K Webb; Andreas B Ipsen; Tsung-Chi Chen; Aleksey V Tolmachev; Erin S Baker; Gordon A Anderson; Richard D Smith
Journal:  Analyst       Date:  2015-10-21       Impact factor: 4.616

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.