Achieving 50% ionization efficiency in subambient pressure ionization with nanoelectrospray.

Ioan Marginean1, Jason S Page, Aleksey V Tolmachev, Keqi Tang, Richard D Smith.   

Abstract

Inefficient ionization and poor transmission of the charged species produced by an electrospray from the ambient pressure mass spectrometer source into the high vacuum region required for mass analysis significantly limits achievable sensitivity. Here, we present evidence that, when operated at flow rates of 50 nL/min, a new electrospray-based ion source operated at ∼20 Torr can deliver ∼50% of the analyte ions initially in the solution as charged desolvated species into the rough vacuum region of mass spectrometers. The ion source can be tuned to optimize the analyte signal for readily ionized species while reducing the background contribution.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21028835      PMCID: PMC2982749          DOI: 10.1021/ac1019123

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  24 in total

1.  Efficiency of nano-electrospray ionization.

Authors:  Ayman El-Faramawy; K W Michael Siu; Bruce A Thomson
Journal:  J Am Soc Mass Spectrom       Date:  2005-10       Impact factor: 3.109

2.  Chemically etched open tubular and monolithic emitters for nanoelectrospray ionization mass spectrometry.

Authors:  Ryan T Kelly; Jason S Page; Quanzhou Luo; Ronald J Moore; Daniel J Orton; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2006-11-15       Impact factor: 6.986

3.  Subambient pressure ionization with nanoelectrospray source and interface for improved sensitivity in mass spectrometry.

Authors:  Jason S Page; Keqi Tang; Ryan T Kelly; Richard D Smith
Journal:  Anal Chem       Date:  2008-02-01       Impact factor: 6.986

4.  Ion transport by viscous gas flow through capillaries.

Authors:  B Lin; J Sunner
Journal:  J Am Soc Mass Spectrom       Date:  1994-10       Impact factor: 3.109

5.  A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes.

Authors:  C G Enke
Journal:  Anal Chem       Date:  1997-12-01       Impact factor: 6.986

6.  Analytical properties of the nanoelectrospray ion source.

Authors:  M Wilm; M Mann
Journal:  Anal Chem       Date:  1996-01-01       Impact factor: 6.986

7.  Charge limits on droplets during evaporation.

Authors:  Kuo-Yen Li; Haohua Tu; Asit K Ray
Journal:  Langmuir       Date:  2005-04-26       Impact factor: 3.882

8.  Analytical characterization of the electrospray ion source in the nanoflow regime.

Authors:  Ioan Marginean; Ryan T Kelly; David C Prior; Brian L LaMarche; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2008-07-29       Impact factor: 6.986

9.  Evaporation and discharge dynamics of highly charged droplets of heptane, octane, and p-xylene generated by electrospray ionization.

Authors:  Ronald L Grimm; J L Beauchamp
Journal:  Anal Chem       Date:  2002-12-15       Impact factor: 6.986

10.  Physical/chemical separations in the break-up of highly charged droplets from electrosprays.

Authors:  K Tang; R D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2001-03       Impact factor: 3.262

View more
  26 in total

1.  Super-atmospheric pressure electrospray ion source: applied to aqueous solution.

Authors:  Lee Chuin Chen; Mridul Kanti Mandal; Kenzo Hiraoka
Journal:  J Am Soc Mass Spectrom       Date:  2011-10-12       Impact factor: 3.109

2.  Improving liquid chromatography-mass spectrometry sensitivity using a subambient pressure ionization with nanoelectrospray (SPIN) interface.

Authors:  Keqi Tang; Jason S Page; Ioan Marginean; Ryan T Kelly; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2011-04-22       Impact factor: 3.109

3.  Protein Structural Studies by Traveling Wave Ion Mobility Spectrometry: A Critical Look at Electrospray Sources and Calibration Issues.

Authors:  Yu Sun; Siavash Vahidi; Modupeola A Sowole; Lars Konermann
Journal:  J Am Soc Mass Spectrom       Date:  2015-09-14       Impact factor: 3.109

4.  Super-Atmospheric Pressure Ion Sources: Application and Coupling to API Mass Spectrometer.

Authors:  Lee Chuin Chen; Md Matiur Rahman; Kenzo Hiraoka
Journal:  Mass Spectrom (Tokyo)       Date:  2014-05-01

Review 5.  New mass spectrometry technologies contributing towards comprehensive and high throughput omics analyses of single cells.

Authors:  Sneha P Couvillion; Ying Zhu; Gabe Nagy; Joshua N Adkins; Charles Ansong; Ryan S Renslow; Paul D Piehowski; Yehia M Ibrahim; Ryan T Kelly; Thomas O Metz
Journal:  Analyst       Date:  2019-01-28       Impact factor: 4.616

6.  On the ionization and ion transmission efficiencies of different ESI-MS interfaces.

Authors:  Jonathan T Cox; Ioan Marginean; Richard D Smith; Keqi Tang
Journal:  J Am Soc Mass Spectrom       Date:  2014-09-30       Impact factor: 3.109

7.  A fundamental study on the [(μ-Cl)3Mg2(THF)6]+ dimer electrolytes for rechargeable Mg batteries.

Authors:  Tianbiao Liu; Jonathan T Cox; Dehong Hu; Xuchu Deng; Jianzhi Hu; Mary Y Hu; Jie Xiao; Yuyan Shao; Keqi Tang; Jun Liu
Journal:  Chem Commun (Camb)       Date:  2015-02-11       Impact factor: 6.222

Review 8.  Single-cell Proteomics: Progress and Prospects.

Authors:  Ryan T Kelly
Journal:  Mol Cell Proteomics       Date:  2020-08-26       Impact factor: 5.911

9.  Electrospray Modifications for Advancing Mass Spectrometric Analysis.

Authors:  Anil Kumar Meher; Yu-Chie Chen
Journal:  Mass Spectrom (Tokyo)       Date:  2017-03-24

10.  In situ SIMS and IR spectroscopy of well-defined surfaces prepared by soft landing of mass-selected ions.

Authors:  Grant E Johnson; K Don Dasitha Gunaratne; Julia Laskin
Journal:  J Vis Exp       Date:  2014-06-16       Impact factor: 1.355