Literature DB >> 10450147

Characterization of an improved electrodynamic ion funnel interface for electrospray ionization mass spectrometry.

S A Shaffer1, A Tolmachev, D C Prior, G A Anderson, H R Udseth, R D Smith.   

Abstract

An improved electrodynamic ion funnel for ion focusing at high pressure (> 1 Torr) has been developed for a triple quadrupole mass spectrometer and its performance compared with that of an earlier prototype previously reported. The ion funnel consists of a series of ring electrodes of progressively smaller internal diameters to which rf and dc electric potentials are co-applied. The new design utilizes ring electrodes possessing larger internal diameters that taper down to a relatively larger exit aperture. In the 1-10 Torr pressure range, the new design provides significant improvement in low m/z ion transmission. Additionally, the overall ion transmission range is improved by linked scanning of the ion funnel's rf voltage concomitantly with the scanning of the quadrupole mass analyzer. Transmission of a noncovalent complex through the interface demonstrated that excessive ion heating was not problematic. Computer simulations of ion transport support the ion funnel design and help explain the relative performance of both designs. Both ion simulations and experimental results are in accord and indicate close to 100% ion transmission efficiency for electrosprayed biopolymer ions through the interface and into the mass analyzer.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10450147     DOI: 10.1021/ac990346w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  34 in total

1.  Single isolated droplets with net charge as a source of ions

Authors: 
Journal:  J Am Soc Mass Spectrom       Date:  2000-05       Impact factor: 3.109

2.  Data-independent proteomic screen identifies novel tamoxifen agonist that mediates drug resistance.

Authors:  Shawna Mae Hengel; Euan Murray; Simon Langdon; Larry Hayward; Jean O'Donoghue; Alexandre Panchaud; Ted Hupp; David R Goodlett
Journal:  J Proteome Res       Date:  2011-09-21       Impact factor: 4.466

3.  Enhanced sensitivity for selected reaction monitoring mass spectrometry-based targeted proteomics using a dual stage electrodynamic ion funnel interface.

Authors:  Mahmud Hossain; David T Kaleta; Errol W Robinson; Tao Liu; Rui Zhao; Jason S Page; Ryan T Kelly; Ronald J Moore; Keqi Tang; David G Camp; Wei-Jun Qian; Richard D Smith
Journal:  Mol Cell Proteomics       Date:  2010-04-21       Impact factor: 5.911

4.  Overtone mobility spectrometry: part 4. OMS-OMS analyses of complex mixtures.

Authors:  Ruwan T Kurulugama; Fabiane M Nachtigall; Stephen J Valentine; David E Clemmer
Journal:  J Am Soc Mass Spectrom       Date:  2011-08-09       Impact factor: 3.109

5.  Investigation of electrospray ionization and electrostatic focusing devices using a three-dimensional electrospray current density profiler.

Authors:  J Will Thompson; John W Eschelbach; Richard T Wilburn; James W Jorgenson
Journal:  J Am Soc Mass Spectrom       Date:  2005-03       Impact factor: 3.109

6.  High-sensitivity ion mobility spectrometry/mass spectrometry using electrodynamic ion funnel interfaces.

Authors:  Keqi Tang; Alexandre A Shvartsburg; Hak-No Lee; David C Prior; Michael A Buschbach; Fumin Li; Aleksey V Tolmachev; Gordon A Anderson; Richard D Smith
Journal:  Anal Chem       Date:  2005-05-15       Impact factor: 6.986

7.  Ion funnels for the masses: experiments and simulations with a simplified ion funnel.

Authors:  Ryan R Julian; Sarah R Mabbett; Martin F Jarrold
Journal:  J Am Soc Mass Spectrom       Date:  2005-10       Impact factor: 3.109

8.  Theoretical and experimental evaluation of the low m/z transmission of an electrodynamic ion funnel.

Authors:  Jason S Page; Aleksey V Tolmachev; Keqi Tang; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2006-02-28       Impact factor: 3.109

9.  Incorporation of a flared inlet capillary tube on a fourier transform ion cyclotron resonance mass spectrometer.

Authors:  Si Wu; Kai Zhang; Nathan K Kaiser; James E Bruce; David C Prior; Gordon A Anderson
Journal:  J Am Soc Mass Spectrom       Date:  2006-04-17       Impact factor: 3.109

10.  Transfer of structural elements from compact to extended states in unsolvated ubiquitin.

Authors:  Stormy L Koeniger; Samuel I Merenbloom; Sundarapandian Sevugarajan; David E Clemmer
Journal:  J Am Chem Soc       Date:  2006-09-06       Impact factor: 15.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.