Literature DB >> 16501412

Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes.

Carlos García-Resúa1, José M González-Meijome, Jorge Gilino, Eva Yebra-Pimentel.   

Abstract

PURPOSE: The ICare (Tiolat Oy, Helsinki, Finland) is a new portable tonometer that measures intraocular pressure (IOP) with a new rebound method, in which a very light probe is used to make momentary contact with the cornea in slow motion. The purpose of this study is to assess the accuracy of the ICare IOP measurements by comparing them against other portable tonometers: Perkins applanation tonometer and Tono-Pen XL digital tonometer (Medtronic Solan, Jacksonville, FL).
METHODS: Sixty-five young subjects were assessed with each of the tonometers. ICare tonometry was performed first, followed by Perkins applanation tonometry and Tono-Pen XL in a random order. Regression analysis was used to evaluate the relationship between the Perkins tonometer and the remaining tonometers used in this study. Tonometers were also compared by plotting the difference between the methods against the mean. The hypothesis of zero bias was examined by a paired t test and the 95% limits of agreement (LoA) were calculated.
RESULTS: ICare and Tono-Pen XL significantly overestimate IOP when compared with Perkins applanation tonometry. The mean of the difference between Perkins and ICare and Perkins and Tono-Pen XL was (mean +/- standard deviation) -3.35 +/- 2.28 mm Hg and -2.78 +/- 2.53 mm Hg, respectively. The 95% LoA between Perkins tonometry and ICare tonometry were between -7.81 and +1.12 and between Perkins tonometry and Tono-Pen XL tonometry between -7.74 and +2.18.
CONCLUSIONS: Compared with Perkins tonometry, the ICare tonometer allows clinicians to estimate IOP with a portable, rapid, and noninvasive method with similar reliability to that offered by Tono-Pen XL. Clinicians should be aware of the systematic overestimation of IOP with the ICare. Further research is needed to evaluate the performance of rebound tonometry in populations with higher IOP and assess the reliability of this technique in the early detection and follow up of glaucomatous patients.

Entities:  

Mesh:

Year:  2006        PMID: 16501412     DOI: 10.1097/01.opx.0000200673.96758.7b

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  17 in total

Review 1.  Rebound tonometry: new opportunities and limitations of non-invasive determination of intraocular pressure.

Authors:  A Cervino
Journal:  Br J Ophthalmol       Date:  2006-12       Impact factor: 4.638

2.  IOP agreement between I-Care TA01 rebound tonometer and the Goldmann applanation tonometer in eyes with and without glaucoma.

Authors:  Gautam Sinha; Shikha Gupta; Shreyas Temkar; Veena Pandey; Ramanjit Sihota; Tanuj Dada
Journal:  Int Ophthalmol       Date:  2014-12-16       Impact factor: 2.031

3.  Age differences in central and peripheral intraocular pressure using a rebound tonometer.

Authors:  J M González-Méijome; J Jorge; A Queirós; P Fernandes; R Montés-Micó; J B Almeida; M A Parafita
Journal:  Br J Ophthalmol       Date:  2006-08-02       Impact factor: 4.638

4.  [Rebound tonometry and applanation tonometry during narcosis investigation of pediatric glaucoma].

Authors:  A Rosentreter; A M Schild; A Lappas; G K Krieglstein; T S Dietlein
Journal:  Ophthalmologe       Date:  2011-04       Impact factor: 1.059

5.  A new rebound tonometer for home monitoring of intraocular pressure.

Authors:  André Rosentreter; Kerstin S Jablonski; Anne C Mellein; Stergiani Gaki; Arno Hueber; Thomas S Dietlein
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-08-14       Impact factor: 3.117

6.  Intraocular pressure with rebound tonometry and effects of topical intraocular pressure reducing medications in guinea pigs.

Authors:  Yue Di; Xiu-Mei Luo; Tong Qiao; Na Lu
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

7.  A comparison of Icare PRO and Perkins tonometers in anesthetized children.

Authors:  Massimiliano Serafino; Edoardo Villani; Andrea Lembo; Giovanni Rabbiolo; Claudia Specchia; Rupal H Trivedi; Paolo Nucci
Journal:  Int Ophthalmol       Date:  2019-07-16       Impact factor: 2.031

8.  Comparison of IOPen rebound tonometer with Goldmann applanation tonometer at different IOP levels.

Authors:  Fereydoun Farrahi; Farideh Sharifipour; Mohammad Malekahmadi; Bahman Cheraghian
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

9.  COMPARISON OF IOP READINGS USING REBOUND I CARE TONOMETER AND PERKINS APPLANATION TONOMETER IN AN AFRICAN POPULATION.

Authors:  D S Ademola-Popoola; A F Odi; T M Akande
Journal:  J West Afr Coll Surg       Date:  2014 Jan-Mar

10.  Intraocular pressure measurements using the TONOVET® rebound tonometer: Influence of the probe-cornea distance.

Authors:  Blanche D Rodrigues; Fabiano Montiani-Ferreira; Mariza Bortolini; André T Somma; András M Komáromy; Peterson Triches Dornbusch
Journal:  Vet Ophthalmol       Date:  2020-10-17       Impact factor: 1.644

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.