Literature DB >> 16171717

Transmission scan truncation with small-field-of-view dedicated cardiac SPECT systems: impact and automated quality control.

Ji Chen1, James R Galt, James A Case, Jinghan Ye, S James Cullom, Mary K Durbin, Ling Shao, Ernest V Garcia.   

Abstract

BACKGROUND: Small-field-of-view (FOV) dedicated cardiac single photon emission computed tomography (SPECT) systems will frequently exhibit severe transmission scan truncation that may degrade attenuation correction (AC). This study evaluated the impact of transmission scan truncation on AC and developed automated transmission scan truncation quality control (ATSTQC) for small-FOV systems. METHODS AND
RESULTS: Small-FOV data were simulated from the data of 10 patients acquired by a full-FOV Philips Vertex system. AC images of the full- and small-FOV data were compared by mean and maximum absolute differences of myocardial counts, and differences in stress and rest severity scores were calculated by use of the Emory Cardiac Toolbox.small-FOV systems. ATSTQC was developed to identify critical truncation that significantly increased these indices and then tested with 18 independent patients. Left-side truncation resulted in significant distortion of the quantitative indices. ATSTQC, developed on the condition that left-side truncation is critical, showed high concordance with the qualitative assessment in identification of critical truncation.
CONCLUSIONS: Identification of left-side truncation as critical truncation is necessary to judge whether accurate AC can be obtained. The developed ATSTQC can accurately detect critical truncation and will help clinicians decide whether to use AC in a particular study.

Entities:  

Mesh:

Year:  2005        PMID: 16171717     DOI: 10.1016/j.nuclcard.2005.04.013

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  10 in total

1.  The value and practice of attenuation correction for myocardial perfusion SPECT imaging: a joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine.

Authors:  Robert C Hendel; James R Corbett; S James Cullom; E Gordon DePuey; Ernest V Garcia; Timothy M Bateman
Journal:  J Nucl Cardiol       Date:  2002 Jan-Feb       Impact factor: 5.952

2.  A two-step Hilbert transform method for 2D image reconstruction.

Authors:  Frédéric Noo; Rolf Clackdoyle; Jed D Pack
Journal:  Phys Med Biol       Date:  2004-09-07       Impact factor: 3.609

3.  Image reconstruction in regions-of-interest from truncated projections in a reduced fan-beam scan.

Authors:  Yu Zou; Xiaochuan Pan; Emil Y Sidky
Journal:  Phys Med Biol       Date:  2005-01-07       Impact factor: 3.609

Review 4.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Impact of attenuation and methods of estimating attenuation maps.

Authors:  M A King; B M Tsui; T S Pan
Journal:  J Nucl Cardiol       Date:  1995 Nov-Dec       Impact factor: 5.952

5.  Effect of truncated projections on defect detection in attenuation-compensated fanbeam cardiac SPECT.

Authors:  G K Gregoriou; B M Tsui; G T Gullberg
Journal:  J Nucl Med       Date:  1998-01       Impact factor: 10.057

6.  Improved coronary disease detection with quantitative attenuation-corrected Tl-201 images.

Authors:  Mathew Shotwell; Balkrishna M Singh; Charlotte Fortman; Brian D Bauman; Jennifer Lukes; Myron C Gerson
Journal:  J Nucl Cardiol       Date:  2002 Jan-Feb       Impact factor: 5.952

7.  Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging.

Authors:  R C Hendel; D S Berman; S J Cullom; W Follansbee; G V Heller; H Kiat; M W Groch; J J Mahmarian
Journal:  Circulation       Date:  1999-06-01       Impact factor: 29.690

8.  Attenuation correction and gating synergistically improve the diagnostic accuracy of myocardial perfusion SPECT.

Authors:  Jonathan M Links; E Gordon DePuey; Raymond Taillefer; Lewis C Becker
Journal:  J Nucl Cardiol       Date:  2002 Mar-Apr       Impact factor: 5.952

9.  Combined corrections for attenuation, depth-dependent blur, and motion in cardiac SPECT: a multicenter trial.

Authors:  J M Links; L C Becker; P Rigo; R Taillefer; L Hanelin; F Anstett; D Burckhardt; L Mixon
Journal:  J Nucl Cardiol       Date:  2000 Sep-Oct       Impact factor: 5.952

10.  Quantitative Tc-99m sestamibi attenuation-corrected SPECT: development and multicenter trial validation of myocardial perfusion stress gender-independent normal database in an obese population.

Authors:  Gabriel B Grossman; Ernest V Garcia; Timothy M Bateman; Gary V Heller; Lynne L Johnson; Russell D Folks; S James Cullom; James R Galt; James A Case; Cesar A Santana; Raghuveer K Halkar
Journal:  J Nucl Cardiol       Date:  2004 May-Jun       Impact factor: 5.952

  10 in total
  5 in total

1.  Attenuation correction in cardiac SPECT: the boy who cried wolf?

Authors:  Guido Germano; Piotr J Slomka; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

2.  Validation of attenuation correction using transmission truncation compensation with a small field of view dedicated cardiac SPECT camera system.

Authors:  Gavin L Noble; Alan W Ahlberg; Aravind Rao Kokkirala; S James Cullom; Timothy M Bateman; Giselle M Cyr; Deborah M Katten; Glenn D Tadeo; James A Case; David M O'Sullivan; Gary V Heller
Journal:  J Nucl Cardiol       Date:  2009-01-22       Impact factor: 5.952

3.  Reconstruction from uniformly attenuated SPECT projection data using the DBH method.

Authors:  Qiu Huang; Jiangsheng You; Gengsheng L Zeng; Grant T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  2009-01       Impact factor: 10.048

4.  Small field-of-view dedicated cardiac SPECT systems: impact of projection truncation.

Authors:  Jianbin Xiao; Fred J Verzijlbergen; Max A Viergever; Freek J Beekman
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-09-01       Impact factor: 9.236

5.  Phantom evaluation of a cardiac SPECT/VCT system that uses a common set of solid-state detectors for both emission and transmission scans.

Authors:  Chuanyong Bai; Richard Conwell; Joel Kindem; Hetal Babla; Mike Gurley; Romer De Los Santos; Rex Old; Randy Weatherhead; Samia Arram; Jamshid Maddahi
Journal:  J Nucl Cardiol       Date:  2010-02-19       Impact factor: 5.952

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.