Improved coronary disease detection with quantitative attenuation-corrected Tl-201 images.

Mathew Shotwell1, Balkrishna M Singh, Charlotte Fortman, Brian D Bauman, Jennifer Lukes, Myron C Gerson.   

Abstract

BACKGROUND: The normal distribution of myocardial tracer activity is different in attenuation-corrected images compared with uncorrected images. We therefore postulated that quantitation of attenuation-corrected thallium 201 images with direct comparison to a database of healthy subjects could improve detection of coronary artery stenoses. METHODS AND
RESULTS: In 49 patients with angiographic evidence of coronary artery disease and 69 patients with a less than 5% likelihood of coronary artery disease, tomographic Tl-201 myocardial imaging was performed by means of a triple-headed camera with fan-beam collimators and the images were processed with attenuation correction, with attenuation and Compton scatter correction, and without correction. Images were subjectively interpreted in a blinded manner. From the group of 69 patients with a low likelihood of coronary disease, scintigraphic data from the first 20 men and the first 20 women were used to generate normal reference ranges for each of the 3 image-processing methods. Data from the 49 patients with angiographic coronary disease and from the remaining 29 patients with a low likelihood of coronary disease were then analyzed quantitatively in comparison to the gender-matched normal databases. With visual interpretation, attenuation-corrected images yielded an improved detection rate compared with uncorrected images (79% vs 46%, P =.008) for 70% or greater left anterior descending coronary artery stenoses. Attenuation-corrected images also provided an improved normalcy rate for the right coronary artery territory (91% vs 75%, P =.006) and an improved normalcy rate when the images were analyzed overall by patient (88% vs 74%, P =.009). With quantitative analysis, attenuation correction yielded an improved detection rate for patients with a significant coronary artery stenosis compared with uncorrected images (90% vs 71%, P =.016). Defect extent was also increased by attenuation correction. Compared with attenuation correction alone, the addition of scatter correction yielded no incremental improvement in detection rate or normalcy rate. Attenuation-scatter correction did produce a nonsignificant trend toward detection of more of the total number of stenotic arteries compared with uncorrected images (60 vs 48 of 79 arteries).
CONCLUSIONS: With the use of a triple-headed camera with fan-beam collimation, visual analysis of attenuation-corrected Tl-201 images improved detection of left anterior descending coronary artery disease without loss of detection in other coronary territories. Furthermore, quantitative analysis of attenuation-corrected Tl-201 images improved the overall detection rate for coronary artery disease in patients without compromise of the normalcy rate.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11845130     DOI: 10.1067/mnc.2002.119252

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  20 in total

1.  A theoretical study of some maximum likelihood algorithms for emission and transmission tomography.

Authors:  K Lange; M Bahn; R Little
Journal:  IEEE Trans Med Imaging       Date:  1987       Impact factor: 10.048

2.  Attenuation-corrected thallium-201 single-photon emission tomography using a gadolinium-153 moving line source: clinical value and the impact of attenuation correction on the extent and severity of perfusion abnormalities.

Authors:  H J Gallowitsch; J Sykora; P Mikosch; E Kresnik; O Unterweger; M Molnar; G Grimm; P Lind
Journal:  Eur J Nucl Med       Date:  1998-03

3.  Impact of attenuation correction by simultaneous emission/transmission tomography on visual assessment of 201Tl myocardial perfusion images.

Authors:  R Vidal; I Buvat; J Darcourt; O Migneco; P Desvignes; M Baudouy; F Bussière
Journal:  J Nucl Med       Date:  1999-08       Impact factor: 10.057

4.  Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: a multicenter trial.

Authors:  K F Van Train; J Maddahi; D S Berman; H Kiat; J Areeda; F Prigent; J Friedman
Journal:  J Nucl Med       Date:  1990-07       Impact factor: 10.057

5.  Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease.

Authors:  G A Diamond; J S Forrester
Journal:  N Engl J Med       Date:  1979-06-14       Impact factor: 91.245

6.  Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution.

Authors:  E P Ficaro; J A Fessler; R J Ackermann; W L Rogers; J R Corbett; M Schwaiger
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

7.  [201Tl myocardial SPECT. First experiences with a simultaneous transmission-emission acquisition protocol for patient-specific attenuated correction].

Authors:  P Knesewitsch; R Walser; R Kantlehner; W Münzing; K Hahn
Journal:  Nuklearmedizin       Date:  1996-06       Impact factor: 1.379

8.  Attenuation correction by simultaneous emission-transmission myocardial single-photon emission tomography using a technetium-99m-labelled radiotracer: impact on diagnostic accuracy.

Authors:  R Kluge; B Sattler; A Seese; W H Knapp
Journal:  Eur J Nucl Med       Date:  1997-09

9.  Quantitative comparison of thallium-201 scintigraphy after exercise and dipyridamole in coronary artery disease.

Authors:  S K Varma; D D Watson; G A Beller
Journal:  Am J Cardiol       Date:  1989-10-15       Impact factor: 2.778

10.  Evaluation of an attenuation correction method for thallium-201 myocardial perfusion tomographic imaging of patients with low likelihood of coronary artery disease.

Authors:  P Chouraqui; S Livschitz; T Sharir; N Wainer; M Wilk; I Moalem; J Baron
Journal:  J Nucl Cardiol       Date:  1998 Jul-Aug       Impact factor: 5.952

View more
  25 in total

1.  Effect of attenuation correction on the interpretation of 99mTc-sestamibi myocardial perfusion scintigraphy: the impact of 1 year's experience.

Authors:  Riemer H J A Slart; Tjin H Que; Dirk J van Veldhuisen; Lieke Poot; Paul K Blanksma; D Albert Piers; Pieter L Jager
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-08-27       Impact factor: 9.236

2.  American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: attenuation correction of myocardial perfusion SPECT scintigraphy.

Authors:  Gary V Heller; Jonathan Links; Timothy M Bateman; Jack A Ziffer; Edward Ficaro; Mylan C Cohen; Robert C Hendel
Journal:  J Nucl Cardiol       Date:  2004 Mar-Apr       Impact factor: 5.952

3.  Transmission scan truncation with small-field-of-view dedicated cardiac SPECT systems: impact and automated quality control.

Authors:  Ji Chen; James R Galt; James A Case; Jinghan Ye; S James Cullom; Mary K Durbin; Ling Shao; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

4.  Attenuation correction in cardiac SPECT: the boy who cried wolf?

Authors:  Guido Germano; Piotr J Slomka; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

5.  SPECT attenuation correction: an essential tool to realize nuclear cardiology's manifest destiny.

Authors:  Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

6.  Automated quality control of emission-transmission misalignment for attenuation correction in myocardial perfusion imaging with SPECT-CT systems.

Authors:  Ji Chen; Serpil F Caputlu-Wilson; Hongcheng Shi; James R Galt; Tracy L Faber; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

7.  Attenuation corrected myocardial perfusion SPECT provides powerful risk stratification in patients with coronary artery disease.

Authors:  Ernest V Garcia; Fabio P Esteves
Journal:  J Nucl Cardiol       Date:  2009-04-03       Impact factor: 5.952

8.  Value of attenuation correction on ECG-gated SPECT myocardial perfusion imaging related to body mass index.

Authors:  Randall C Thompson; Gary V Heller; Lynne L Johnson; James A Case; S James Cullom; Ernest V Garcia; Philip G Jones; Kelly L Moutray; Timothy M Bateman
Journal:  J Nucl Cardiol       Date:  2005 Mar-Apr       Impact factor: 5.952

9.  Clinical validation of SPECT attenuation correction using x-ray computed tomography-derived attenuation maps: multicenter clinical trial with angiographic correlation.

Authors:  Yasmin Masood; Yi-Hwa Liu; Gordon Depuey; Raymond Taillefer; Luis I Araujo; Steven Allen; Dominique Delbeke; Frank Anstett; Aharon Peretz; Mary-Jo Zito; Vera Tsatkin; Frans J Th Wackers
Journal:  J Nucl Cardiol       Date:  2005 Nov-Dec       Impact factor: 5.952

Review 10.  Attenuation correction for single photon emission computed tomography myocardial perfusion imaging.

Authors:  James R Corbett; James N Kritzman; Edward P Ficaro
Journal:  Curr Cardiol Rep       Date:  2004-01       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.