Literature DB >> 15715419

Image reconstruction in regions-of-interest from truncated projections in a reduced fan-beam scan.

Yu Zou1, Xiaochuan Pan, Emil Y Sidky.   

Abstract

In a reduced fan-beam scan, the scanned angular range is smaller than that in a short scan (i.e., a half-scan). In this work, we have developed a new algorithm, which is referred to as the backprojection-filtration (BPF) algorithm, for exact image reconstruction within ROIs from reduced-scan data containing truncations. Explicit conditions on data acquisition have also been derived for exact image reconstruction within an ROI. We have performed a preliminary quantitative study whose results demonstrated and verified the proposed fan-beam BPF algorithm and the derived conditions on data acquisition. The proposed BPF algorithm can have significant implications for clinical and animal CT imaging, therapy imaging, electron paramagnetic resonance imaging and other tomographic imaging because it allows for reconstruction from truncated data and for a potentially drastic reduction of radiation dose and/or of imaging time.

Mesh:

Year:  2005        PMID: 15715419     DOI: 10.1088/0031-9155/50/1/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  19 in total

1.  Gel'fand-Graev's reconstruction formula in the 3D real space.

Authors:  Yangbo Ye; Hengyong Yu; Ge Wang
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

2.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

3.  Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT.

Authors:  Guang-Hong Chen; Yinsheng Li
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

4.  Transmission scan truncation with small-field-of-view dedicated cardiac SPECT systems: impact and automated quality control.

Authors:  Ji Chen; James R Galt; James A Case; Jinghan Ye; S James Cullom; Mary K Durbin; Ling Shao; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

5.  Validation of attenuation correction using transmission truncation compensation with a small field of view dedicated cardiac SPECT camera system.

Authors:  Gavin L Noble; Alan W Ahlberg; Aravind Rao Kokkirala; S James Cullom; Timothy M Bateman; Giselle M Cyr; Deborah M Katten; Glenn D Tadeo; James A Case; David M O'Sullivan; Gary V Heller
Journal:  J Nucl Cardiol       Date:  2009-01-22       Impact factor: 5.952

6.  Dual resolution cone beam breast CT: a feasibility study.

Authors:  Lingyun Chen; Youtao Shen; Chao-Jen Lai; Tao Han; Yuncheng Zhong; Shuaiping Ge; Xinming Liu; Tianpeng Wang; Wei T Yang; Gary J Whitman; Chris C Shaw
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

7.  Multiresolution reconstruction for cone-beam tomography from raw data projections using 3D ridgelets.

Authors:  Francisco Gómez; Cristina Santa Marta; Eduardo Romero
Journal:  J Digit Imaging       Date:  2011-12       Impact factor: 4.056

8.  Dynamic detector offsets for field of view extension in C-arm computed tomography with application to weight-bearing imaging.

Authors:  Magdalena Herbst; Frank Schebesch; Martin Berger; Jang-Hwan Choi; Rebecca Fahrig; Joachim Hornegger; Andreas Maier
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

9.  Reconstructing cone-beam CT with spatially varying qualities for adaptive radiotherapy: a proof-of-principle study.

Authors:  Wenting Lu; Hao Yan; Xuejun Gu; Zhen Tian; Ouyang Luo; Liu Yang; Linghong Zhou; Laura Cervino; Jing Wang; Steve Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2014-09-26       Impact factor: 3.609

10.  Volume-of-change cone-beam CT for image-guided surgery.

Authors:  Junghoon Lee; J Webster Stayman; Yoshito Otake; Sebastian Schafer; Wojciech Zbijewski; A Jay Khanna; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2012-07-17       Impact factor: 3.609

View more