Literature DB >> 15173773

Quantitative Tc-99m sestamibi attenuation-corrected SPECT: development and multicenter trial validation of myocardial perfusion stress gender-independent normal database in an obese population.

Gabriel B Grossman1, Ernest V Garcia, Timothy M Bateman, Gary V Heller, Lynne L Johnson, Russell D Folks, S James Cullom, James R Galt, James A Case, Cesar A Santana, Raghuveer K Halkar.   

Abstract

BACKGROUND: A gender-independent stress normal database and criteria for abnormality for attenuation-corrected rest-stress technetium 99m sestamibi same-day myocardial perfusion imaging were developed by evaluation of 112 patients, validated against an obese population of 95 patients from four different clinical sites, and compared with conventional gender-matched database quantification of non-attenuation-corrected studies. METHODS AND
RESULTS: These 95 validation patients (63 men) were used for prospective quantitative evaluation (mean weight, 213 +/- 57 lb; mean body mass index, 32 +/- 9 kg/m(2)). This group included 21 patients (12 men) with a lower than 5% likelihood of coronary artery disease (mean weight, 226 +/- 72 lb; mean body mass index, 34 +/- 13 kg/m(2)) and 74 who underwent cardiac catheterization within 2 months (35 with normal coronaries or coronary lesions <70%). These studies were processed twice, once by use of conventional reconstruction and gender-specific database quantification and a second time by use of attenuation correction and a single gender-independent attenuation-corrected normal database. The attenuation-corrected normal database and criteria for abnormality were developed by evaluation of 48 and 78 patients, respectively. No statistically significant differences were found when comparing attenuation-corrected perfusion distributions of normal men and women, whereas significant differences were found in the same uncorrected studies. Compared with quantitative analysis of the uncorrected studies, quantitative analysis of the attenuation-corrected studies by use of a gender-independent normal database demonstrated a significant improvement in normalcy rate (90% vs 52%, P =.006) and specificity (57% vs 29%, P =.015) in this obese population at no significant loss in sensitivity (90% vs 97%, P = not significant).
CONCLUSION: Attenuation-corrected studies can be quantified with a single gender-independent normal database and a single criterion for abnormality without loss of sensitivity and with significantly better specificity and normalcy rate.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15173773     DOI: 10.1016/j.nuclcard.2004.02.007

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  24 in total

1.  Optimal specificity of thallium-201 SPECT through recognition of imaging artifacts.

Authors:  E G DePuey; E V Garcia
Journal:  J Nucl Med       Date:  1989-04       Impact factor: 10.057

2.  Prone decubitus: a solution to inferior wall attenuation in thallium-201 myocardial tomography.

Authors:  J P Esquerré; F J Coca; S J Martinez; R F Guiraud
Journal:  J Nucl Med       Date:  1989-03       Impact factor: 10.057

3.  Improved coronary disease detection with quantitative attenuation-corrected Tl-201 images.

Authors:  Mathew Shotwell; Balkrishna M Singh; Charlotte Fortman; Brian D Bauman; Jennifer Lukes; Myron C Gerson
Journal:  J Nucl Cardiol       Date:  2002 Jan-Feb       Impact factor: 5.952

4.  Quantitative same-day rest-stress technetium-99m-sestamibi SPECT: definition and validation of stress normal limits and criteria for abnormality.

Authors:  K F Van Train; J Areeda; E V Garcia; C D Cooke; J Maddahi; H Kiat; G Germano; G Silagan; R Folks; D S Berman
Journal:  J Nucl Med       Date:  1993-09       Impact factor: 10.057

5.  Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: differential stratification for risk of cardiac death and myocardial infarction.

Authors:  R Hachamovitch; D S Berman; L J Shaw; H Kiat; I Cohen; J A Cabico; J Friedman; G A Diamond
Journal:  Circulation       Date:  1998-02-17       Impact factor: 29.690

Review 6.  Clinical review of attenuation-corrected cardiac SPECT.

Authors:  J R Corbett; E P Ficaro
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

7.  Multicenter trial validation for quantitative analysis of same-day rest-stress technetium-99m-sestamibi myocardial tomograms.

Authors:  K F Van Train; E V Garcia; J Maddahi; J Areeda; C D Cooke; H Kiat; G Silagan; R Folks; J Friedman; L Matzer
Journal:  J Nucl Med       Date:  1994-04       Impact factor: 10.057

8.  Quantitative analysis of stress thallium-201 myocardial scintigrams: a multicenter trial.

Authors:  K F Van Train; D S Berman; E V Garcia; H J Berger; M J Sands; J D Friedman; M R Freeman; M Pryzlak; W L Ashburn; S L Norris
Journal:  J Nucl Med       Date:  1986-01       Impact factor: 10.057

9.  Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact.

Authors:  E G DePuey; A Rozanski
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

10.  Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease.

Authors:  E E DePasquale; A C Nody; E G DePuey; E V Garcia; G Pilcher; C Bredlau; G Roubin; A Gober; A Gruentzig; P D'Amato
Journal:  Circulation       Date:  1988-02       Impact factor: 29.690

View more
  52 in total

1.  Is it time for SPECT attenuation correction?

Authors:  Denny D Watson
Journal:  J Nucl Cardiol       Date:  2004 May-Jun       Impact factor: 5.952

2.  Yield of a novel ultra-low-dose computed tomography device mounted on a dedicated cardiac SPECT system in improving the accuracy of myocardial perfusion imaging and the detection of chest abnormalities.

Authors:  Nili Zafrir; Gigeon Shafir; Gil Kovalski; Israel Mats; Jean-Paul Bouhnik; Alexander Battler; Alejandro Solodky
Journal:  J Nucl Cardiol       Date:  2011-12-28       Impact factor: 5.952

3.  Quantitative Nuclear Cardiology: we are almost there!

Authors:  Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2012-03-31       Impact factor: 5.952

4.  Attenuation correction reveals gender-related differences in the normal values of transient ischemic dilation index in rest-exercise stress sestamibi myocardial perfusion imaging.

Authors:  Abel Rivero; Cesar Santana; Russell D Folks; Fabio Esteves; Liudmila Verdes; Shorena Esiashvili; Gabriel B Grossman; Raghuveer K Halkar; Timothy M Bateman; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2006 May-Jun       Impact factor: 5.952

5.  Automated quantification of myocardial perfusion SPECT using simplified normal limits.

Authors:  Piotr J Slomka; Hidetaka Nishina; Daniel S Berman; Cigdem Akincioglu; Aiden Abidov; John D Friedman; Sean W Hayes; Guido Germano
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

6.  Transmission scan truncation with small-field-of-view dedicated cardiac SPECT systems: impact and automated quality control.

Authors:  Ji Chen; James R Galt; James A Case; Jinghan Ye; S James Cullom; Mary K Durbin; Ling Shao; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

Review 7.  Optimal SPECT processing and display: making bad studies look good to get the right answer.

Authors:  Dalia Y Ibrahim; Frank P DiFilippo; Jeremy E Steed; Manuel D Cerqueira
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

8.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

9.  Diagnostic accuracy of gated Tc-99m sestamibi stress myocardial perfusion SPECT with combined supine and prone acquisitions to detect coronary artery disease in obese and nonobese patients.

Authors:  Daniel S Berman; Xingping Kang; Hidetaka Nishina; Piotr J Slomka; Leslee J Shaw; Sean W Hayes; Ishac Cohen; John D Friedman; James Gerlach; Guido Germano
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

10.  Diagnostic performance of low-dose rest/stress Tc-99m tetrofosmin myocardial perfusion SPECT using the 530c CZT camera: quantitative vs visual analysis.

Authors:  Fabio P Esteves; James R Galt; Russell D Folks; Liudmila Verdes; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2013-11-28       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.