Literature DB >> 16156355

Standardized evaluation methodology for 2-D-3-D registration.

Everine B van de Kraats1, Graeme P Penney, Dejan Tomazevic, Theo van Walsum, Wiro J Niessen.   

Abstract

In the past few years, a number of two-dimensional (2-D) to three-dimensional (3-D) (2-D-3-D) registration algorithms have been introduced. However, these methods have been developed and evaluated for specific applications, and have not been directly compared. Understanding and evaluating their performance is therefore an open and important issue. To address this challenge we introduce a standardized evaluation methodology, which can be used for all types of 2-D-3-D registration methods and for different applications and anatomies. Our evaluation methodology uses the calibrated geometry of a 3-D rotational X-ray (3DRX) imaging system (Philips Medical Systems, Best, The Netherlands) in combination with image-based 3-D-3-D registration for attaining a highly accurate gold standard for 2-D X-ray to 3-D MR/CT/3DRX registration. Furthermore, we propose standardized starting positions and failure criteria to allow future researchers to directly compare their methods. As an illustration, the proposed methodology has been used to evaluate the performance of two 2-D-3-D registration techniques, viz. a gradient-based and an intensity-based method, for images of the spine. The data and gold standard transformations are available on the internet (http://www.isi.uu.nl/Research/Databases/).

Mesh:

Year:  2005        PMID: 16156355     DOI: 10.1109/TMI.2005.853240

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  23 in total

1.  Rigid registration of medical images using 1D and 2D binary projections.

Authors:  Panayiotis Kotsas; Tony Dodd
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

2.  Fully automatic initialization of two-dimensional-three-dimensional medical image registration using hybrid classifier.

Authors:  Jing Wu; Emam E Abdel Fatah; Mohamed R Mahfouz
Journal:  J Med Imaging (Bellingham)       Date:  2015-06-02

3.  Real-time 6DoF pose recovery from X-ray images using library-based DRR and hybrid optimization.

Authors:  S Miao; A Tuysuzoglu; Z J Wang; R Liao
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-04-02       Impact factor: 2.924

4.  A framework for automatic creation of gold-standard rigid 3D-2D registration datasets.

Authors:  Hennadii Madan; Franjo Pernuš; Boštjan Likar; Žiga Špiclin
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-09-21       Impact factor: 2.924

5.  3D-2D registration for surgical guidance: effect of projection view angles on registration accuracy.

Authors:  A Uneri; Y Otake; A S Wang; G Kleinszig; S Vogt; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2013-12-19       Impact factor: 3.609

6.  Patient-tailored plate for bone fixation and accurate 3D positioning in corrective osteotomy.

Authors:  J G G Dobbe; J C Vroemen; S D Strackee; G J Streekstra
Journal:  Med Biol Eng Comput       Date:  2012-10-10       Impact factor: 2.602

7.  Intraoperative image-based multiview 2D/3D registration for image-guided orthopaedic surgery: incorporation of fiducial-based C-arm tracking and GPU-acceleration.

Authors:  Yoshito Otake; Mehran Armand; Robert S Armiger; Michael D Kutzer; Ehsan Basafa; Peter Kazanzides; Russell H Taylor
Journal:  IEEE Trans Med Imaging       Date:  2011-11-18       Impact factor: 10.048

8.  3D-2D registration in endovascular image-guided surgery: evaluation of state-of-the-art methods on cerebral angiograms.

Authors:  Uroš Mitrović; Boštjan Likar; Franjo Pernuš; Žiga Špiclin
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-10-24       Impact factor: 2.924

9.  Efficient implementation of the rank correlation merit function for 2D/3D registration.

Authors:  M Figl; C Bloch; C Gendrin; C Weber; S A Pawiro; J Hummel; P Markelj; F Pernus; H Bergmann; W Birkfellner
Journal:  Phys Med Biol       Date:  2010-09-16       Impact factor: 3.609

10.  Evaluation of a system for high-accuracy 3D image-based registration of endoscopic video to C-arm cone-beam CT for image-guided skull base surgery.

Authors:  Daniel J Mirota; Ali Uneri; Sebastian Schafer; Sajendra Nithiananthan; Douglas D Reh; Masaru Ishii; Gary L Gallia; Russell H Taylor; Gregory D Hager; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2013-01-28       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.