Literature DB >> 22113773

Intraoperative image-based multiview 2D/3D registration for image-guided orthopaedic surgery: incorporation of fiducial-based C-arm tracking and GPU-acceleration.

Yoshito Otake1, Mehran Armand, Robert S Armiger, Michael D Kutzer, Ehsan Basafa, Peter Kazanzides, Russell H Taylor.   

Abstract

Intraoperative patient registration may significantly affect the outcome of image-guided surgery (IGS). Image-based registration approaches have several advantages over the currently dominant point-based direct contact methods and are used in some industry solutions in image-guided radiation therapy with fixed X-ray gantries. However, technical challenges including geometric calibration and computational cost have precluded their use with mobile C-arms for IGS. We propose a 2D/3D registration framework for intraoperative patient registration using a conventional mobile X-ray imager combining fiducial-based C-arm tracking and graphics processing unit (GPU)-acceleration. The two-stage framework 1) acquires X-ray images and estimates relative pose between the images using a custom-made in-image fiducial, and 2) estimates the patient pose using intensity-based 2D/3D registration. Experimental validations using a publicly available gold standard dataset, a plastic bone phantom and cadaveric specimens have been conducted. The mean target registration error (mTRE) was 0.34 ± 0.04 mm (success rate: 100%, registration time: 14.2 s) for the phantom with two images 90° apart, and 0.99 ± 0.41 mm (81%, 16.3 s) for the cadaveric specimen with images 58.5° apart. The experimental results showed the feasibility of the proposed registration framework as a practical alternative for IGS routines.

Entities:  

Mesh:

Year:  2011        PMID: 22113773      PMCID: PMC4451116          DOI: 10.1109/TMI.2011.2176555

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  40 in total

1.  3-D/2-D registration of CT and MR to X-ray images.

Authors:  Dejan Tomazevic; Bostjan Likar; Tomaz Slivnik; Franjo Pernus
Journal:  IEEE Trans Med Imaging       Date:  2003-11       Impact factor: 10.048

2.  Automatic registration of portal images and volumetric CT for patient positioning in radiation therapy.

Authors:  Ali Khamene; Peter Bloch; Wolfgang Wein; Michelle Svatos; Frank Sauer
Journal:  Med Image Anal       Date:  2005-09-08       Impact factor: 8.545

3.  3D/2D model-to-image registration applied to TIPS surgery.

Authors:  Julien Jomier; Elizabeth Bullitt; Mark Van Horn; Chetna Pathak; Stephen R Aylward
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

4.  C-arm tracking and reconstruction without an external tracker.

Authors:  Ameet Jain; Gabor Fichtinger
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

Review 5.  Advances in image-guided radiation therapy.

Authors:  Laura A Dawson; David A Jaffray
Journal:  J Clin Oncol       Date:  2007-03-10       Impact factor: 44.544

6.  Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy.

Authors:  Jian Wu; Minho Kim; Jorg Peters; Heeteak Chung; Sanjiv S Samant
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

7.  Geometric calibration of a mobile C-arm for intraoperative cone-beam CT.

Authors:  M J Daly; J H Siewerdsen; Y B Cho; D A Jaffray; J C Irish
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

8.  Validation for 2D/3D registration. II: The comparison of intensity- and gradient-based merit functions using a new gold standard data set.

Authors:  Christelle Gendrin; Primoz Markelj; Supriyanto Ardjo Pawiro; Jakob Spoerk; Christoph Bloch; Christoph Weber; Michael Figl; Helmar Bergmann; Wolfgang Birkfellner; Bostjan Likar; Franjo Pernus
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

9.  2D-3D registration of coronary angiograms for cardiac procedure planning and guidance.

Authors:  Guy-Anne Turgeon; Glen Lehmann; Gerard Guiraudon; Maria Drangova; David Holdsworth; Terry Peters
Journal:  Med Phys       Date:  2005-12       Impact factor: 4.071

10.  Validation for 2D/3D registration. I: A new gold standard data set.

Authors:  S A Pawiro; P Markelj; F Pernus; C Gendrin; M Figl; C Weber; F Kainberger; I Nöbauer-Huhmann; H Bergmeister; M Stock; D Georg; H Bergmann; W Birkfellner
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

View more
  26 in total

1.  Minimally invasive registration for computer-assisted orthopedic surgery: combining tracked ultrasound and bone surface points via the P-IMLOP algorithm.

Authors:  Seth Billings; Hyun Jae Kang; Alexis Cheng; Emad Boctor; Peter Kazanzides; Russell Taylor
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-18       Impact factor: 2.924

2.  Multimodal image registration with joint structure tensor and local entropy.

Authors:  Jingya Zhang; Jiajun Wang; Xiuying Wang; Dagan Feng
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-05-28       Impact factor: 2.924

3.  Can real-time RGBD enhance intraoperative Cone-Beam CT?

Authors:  Javad Fotouhi; Bernhard Fuerst; Wolfgang Wein; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-03-25       Impact factor: 2.924

4.  Fast reconstructed radiographs from octree-compressed volumetric data.

Authors:  Mark Fisher; Osama Dorgham; Stephen D Laycock
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-07-22       Impact factor: 2.924

5.  Rendering-Based Video-CT Registration with Physical Constraints for Image-Guided Endoscopic Sinus Surgery.

Authors:  Y Otake; S Leonard; A Reiter; P Rajan; J H Siewerdsen; G L Gallia; M Ishii; R H Taylor; G D Hager
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-02-21

6.  Robustness and accuracy of feature-based single image 2-D-3-D registration without correspondences for image-guided intervention.

Authors:  Mehran Armand; Yoshito Otake; Paul Y S Cheung; Russell H Taylor
Journal:  IEEE Trans Biomed Eng       Date:  2013-08-15       Impact factor: 4.538

7.  Pose-aware C-arm for automatic re-initialization of interventional 2D/3D image registration.

Authors:  Javad Fotouhi; Bernhard Fuerst; Alex Johnson; Sing Chun Lee; Russell Taylor; Greg Osgood; Nassir Navab; Mehran Armand
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-05-19       Impact factor: 2.924

8.  Motion compensation in extremity cone-beam CT using a penalized image sharpness criterion.

Authors:  A Sisniega; J W Stayman; J Yorkston; J H Siewerdsen; W Zbijewski
Journal:  Phys Med Biol       Date:  2017-03-22       Impact factor: 3.609

9.  Pose Estimation of Periacetabular Osteotomy Fragments With Intraoperative X-Ray Navigation.

Authors:  Robert B Grupp; Rachel A Hegeman; Ryan J Murphy; Clayton P Alexander; Yoshito Otake; Benjamin A McArthur; Mehran Armand; Russell H Taylor
Journal:  IEEE Trans Biomed Eng       Date:  2019-05-06       Impact factor: 4.538

10.  Significance of preoperative planning for prophylactic augmentation of osteoporotic hip: A computational modeling study.

Authors:  Amirhossein Farvardin; Ehsan Basafa; Mahsan Bakhtiarinejad; Mehran Armand
Journal:  J Biomech       Date:  2019-07-19       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.