Literature DB >> 26158102

Fully automatic initialization of two-dimensional-three-dimensional medical image registration using hybrid classifier.

Jing Wu1, Emam E Abdel Fatah1, Mohamed R Mahfouz1.   

Abstract

X-ray video fluoroscopy along with two-dimensional-three-dimensional (2D-3D) registration techniques is widely used to study joints in vivo kinematic behaviors. These techniques, however, are generally very sensitive to the initial alignment of the 3-D model. We present an automatic initialization method for 2D-3D registration of medical images. The contour of the knee bone or implant was first automatically extracted from a 2-D x-ray image. Shape descriptors were calculated by normalized elliptical Fourier descriptors to represent the contour shape. The optimal pose was then determined by a hybrid classifier combining [Formula: see text]-nearest neighbors and support vector machine. The feasibility of the method was first validated on computer synthesized images, with 100% successful estimation for the femur and tibia implants, 92% for the femur and 95% for the tibia. The method was further validated on fluoroscopic x-ray images with all the poses of the testing cases successfully estimated. Finally, the method was evaluated as an initialization of a feature-based 2D-3D registration. The initialized and uninitialized registrations had success rates of 100% and 50%, respectively. The proposed method can be easily utilized for 2D-3D image registration on various medical objects and imaging modalities.

Keywords:  2D-3D registration; computed tomography image; kinematics; pose estimation; support vector machine; x-ray fluoroscopic image

Year:  2015        PMID: 26158102      PMCID: PMC4478960          DOI: 10.1117/1.JMI.2.2.024007

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  19 in total

1.  Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy.

Authors:  William A. Hoff; Richard D. Komistek; Douglas A. Dennis; Stefan M. Gabriel; Scott A. Walker
Journal:  Clin Biomech (Bristol, Avon)       Date:  1998-10       Impact factor: 2.063

2.  Robust initialization of 2D-3D image registration using the projection-slice theorem and phase correlation.

Authors:  M J van der Bom; L W Bartels; M J Gounis; R Homan; J Timmer; M A Viergever; J P W Pluim
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

3.  Standardized evaluation methodology for 2-D-3-D registration.

Authors:  Everine B van de Kraats; Graeme P Penney; Dejan Tomazevic; Theo van Walsum; Wiro J Niessen
Journal:  IEEE Trans Med Imaging       Date:  2005-09       Impact factor: 10.048

4.  Automatic methods for characterization of sexual dimorphism of adult femora: distal femur.

Authors:  M R Mahfouz; B C Merkl; E E Abdel Fatah; R Booth; J N Argenson
Journal:  Comput Methods Biomech Biomed Engin       Date:  2007-09-24       Impact factor: 1.763

5.  Patella sex determination by 3D statistical shape models and nonlinear classifiers.

Authors:  Mohamed Mahfouz; Ahmed Badawi; Brandon Merkl; Emam E Abdel Fatah; Emily Pritchard; Katherine Kesler; Megan Moore; Richard Jantz; Lee Jantz
Journal:  Forensic Sci Int       Date:  2007-05-07       Impact factor: 2.395

6.  Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty.

Authors:  J B Stiehl; R D Komistek; D A Dennis; R D Paxson; W A Hoff
Journal:  J Bone Joint Surg Br       Date:  1995-11

7.  Predicting error in rigid-body point-based registration.

Authors:  J M Fitzpatrick; J B West; C R Maurer
Journal:  IEEE Trans Med Imaging       Date:  1998-10       Impact factor: 10.048

8.  Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy.

Authors:  S A Banks; W A Hodge
Journal:  IEEE Trans Biomed Eng       Date:  1996-06       Impact factor: 4.538

9.  Improving sex estimation from crania using a novel three-dimensional quantitative method.

Authors:  Emam E Abdel Fatah; Natalie R Shirley; Richard L Jantz; Mohamed R Mahfouz
Journal:  J Forensic Sci       Date:  2014-02-06       Impact factor: 1.832

10.  An automatic 2D-3D image matching method for reproducing spatial knee joint positions using single or dual fluoroscopic images.

Authors:  Zhonglin Zhu; Guoan Li
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-08-01       Impact factor: 1.763

View more
  2 in total

1.  Robust x-ray image segmentation by spectral clustering and active shape model.

Authors:  Jing Wu; Mohamed R Mahfouz
Journal:  J Med Imaging (Bellingham)       Date:  2016-09-20

2.  Reconstruction of knee anatomy from single-plane fluoroscopic x-ray based on a nonlinear statistical shape model.

Authors:  Jing Wu; Mohamed R Mahfouz
Journal:  J Med Imaging (Bellingham)       Date:  2021-01-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.