Constrained acetabular liners: mechanisms of failure.

Andrew G Yun1, Douglas Padgett, Paul Pellicci, Lawrence D Dorr.   

Abstract

Although constrained acetabular liners have been successfully used for the treatment of recurrent hip instability, their usage has led to a growing number of associated complications. Twenty-seven patients (29 hips) who experienced failure of the constrained acetabular construct were retrospectively reviewed to define mechanisms of failure. Of these patients, 8 had a recurrent failure of another constrained liner. The 4 modes of failure were failure of fixation to the pelvis, liner dissociation, biomaterial failure, and femoral head dislocation. As constrained liners are highly subject to mechanical overload, the risk of failure can be minimized by reducing prosthetic impingement and avoiding technical errors.

Entities:  

Mesh:

Year:  2005        PMID: 16124973     DOI: 10.1016/j.arth.2004.12.054

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  16 in total

1.  Constrained cups appear incapable of meeting the demands of revision THA.

Authors:  Philip C Noble; Salim K Durrani; Molly M Usrey; Kenneth B Mathis; Nikolaos V Bardakos
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  The use of a cemented dual mobility socket to treat recurrent dislocation.

Authors:  Moussa Hamadouche; David J Biau; Denis Huten; Thierry Musset; François Gaucher
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

3.  Revision for taper corrosion at the neck-body junction following total hip arthroplasty: pearls and pitfalls.

Authors:  Mitchell C Weiser; Darwin D Chen
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

4.  The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years.

Authors:  Remi Philippot; Jean Philippe Camilleri; Bertrand Boyer; Philippe Adam; Frederic Farizon
Journal:  Int Orthop       Date:  2008-06-03       Impact factor: 3.075

5.  Use of a dual mobility socket to manage total hip arthroplasty instability.

Authors:  Olivier Guyen; Vincent Pibarot; Gualter Vaz; Christophe Chevillotte; Jacques Béjui-Hugues
Journal:  Clin Orthop Relat Res       Date:  2008-09-09       Impact factor: 4.176

6.  Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations: five year results from Lithuanian arthroplasty register.

Authors:  Justinas Stucinskas; Tomas Kalvaitis; Alfredas Smailys; Otto Robertsson; Sarunas Tarasevicius
Journal:  Int Orthop       Date:  2017-12-02       Impact factor: 3.075

7.  The focally constrained liner is a reasonable option for revision of unstable total hip arthroplasty.

Authors:  Tatu J Mäkinen; Simcha G Fichman; Wael A Rahman; Tomas Amenabar; Oleg Safir; Allan E Gross; Paul R T Kuzyk
Journal:  Int Orthop       Date:  2015-12-23       Impact factor: 3.075

Review 8.  Constrained components for the unstable hip following total hip arthroplasty: a literature review.

Authors:  J T Williams; P S Ragland; S Clarke
Journal:  Int Orthop       Date:  2006-08-23       Impact factor: 3.075

9.  Acetabular liner with focal constraint to prevent dislocation after THA.

Authors:  Jacob T Munro; Mihai H Vioreanu; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

10.  Application of viscoelastic fracture model and non-uniform crack initiation at clinically relevant notches in crosslinked UHMWPE.

Authors:  P Abhiram Sirimamilla; Jevan Furmanski; Clare M Rimnac
Journal:  J Mech Behav Biomed Mater       Date:  2012-08-01
View more