Literature DB >> 16927089

Constrained components for the unstable hip following total hip arthroplasty: a literature review.

J T Williams1, P S Ragland, S Clarke.   

Abstract

Patients with chronic instability or late dislocation following total hip arthroplasty often require operative management. Unfortunately, there is an increased risk of recurrent dislocation following revision in these patients. Over the past decade the use of constrained devices for patients with chronic instability has gained increased interest; however, there is a paucity of studies available in the literature regarding the use of these devices. The purpose of this study was to analyze the available literature over the past 15 years, focusing on larger, long-term studies, to obtain recommendations from the respective articles for indications and contraindications for the use of constrained devices. Our review of eight reports included 1,199 hips in 1,148 patients with a total mean follow-up of 51 months (range, 24 to 124 months). The mean rate of dislocation following revision with a constrained liner was 10% and the mean re-operation rate for reasons other than dislocation was 4%. We concluded that constrained liners are an option for patients who have failed management of instability with other implants, those with instability of unclear etiology, those with cognitive problems who are unable to follow dislocation precautions, those with deficient abductors, and elderly or low-demand individuals with well-positioned implants requiring revision.

Entities:  

Mesh:

Year:  2006        PMID: 16927089      PMCID: PMC2267591          DOI: 10.1007/s00264-006-0191-y

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  18 in total

1.  Use of constrained acetabular components for hip instability: an average 10-year follow-up study.

Authors:  Barron R B Bremner; Devon D Goetz; John J Callaghan; William N Capello; Richard C Johnston
Journal:  J Arthroplasty       Date:  2003-10       Impact factor: 4.757

2.  Periprosthetic acetabular bone loss using a constrained acetabular component.

Authors:  Hiroshi Ito; Takeo Matsuno
Journal:  Arch Orthop Trauma Surg       Date:  2003-12-02       Impact factor: 3.067

3.  Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty: a review of our experience.

Authors:  John J Callaghan; Michael R O'Rourke; Devon D Goetz; David G Lewallen; Richard C Johnston; William N Capello
Journal:  Clin Orthop Relat Res       Date:  2004-12       Impact factor: 4.176

4.  The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty examining the successes and failures.

Authors:  Keith R Berend; Adolph V Lombardi; Thomas H Mallory; Joanne B Adams; Jackie H Russell; Kari L Groseth
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

5.  Constrained acetabular liners: mechanisms of failure.

Authors:  Andrew G Yun; Douglas Padgett; Paul Pellicci; Lawrence D Dorr
Journal:  J Arthroplasty       Date:  2005-06       Impact factor: 4.757

6.  Constrained acetabular components.

Authors:  M J Anderson; W R Murray; H B Skinner
Journal:  J Arthroplasty       Date:  1994-02       Impact factor: 4.757

7.  High failure rate of a constrained acetabular liner in revision total hip arthroplasty.

Authors:  Craig J Della Valle; Dennis Chang; Scott Sporer; Richard A Berger; Aaron G Rosenberg; Wayne G Paprosky
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

8.  Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component. A concise follow-up of a previous report.

Authors:  Devon D Goetz; Barron R B Bremner; John J Callaghan; William N Capello; Richard C Johnston
Journal:  J Bone Joint Surg Am       Date:  2004-11       Impact factor: 5.284

9.  Preliminary report on the S-ROM constraining acetabular insert: a retrospective clinical experience.

Authors:  A V Lombardi; T H Mallory; T J Kraus; B K Vaughn
Journal:  Orthopedics       Date:  1991-03       Impact factor: 1.390

10.  Salvage of total hip instability with a constrained acetabular component.

Authors:  D D Goetz; W N Capello; J J Callaghan; T D Brown; R C Johnston
Journal:  Clin Orthop Relat Res       Date:  1998-10       Impact factor: 4.176

View more
  31 in total

1.  Constrained cups appear incapable of meeting the demands of revision THA.

Authors:  Philip C Noble; Salim K Durrani; Molly M Usrey; Kenneth B Mathis; Nikolaos V Bardakos
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  Dual mobility cups for preventing early hip arthroplasty dislocation in patients at risk: experience in a county hospital.

Authors:  Sebastian S Mukka; Sarwar S Mahmood; Göran O Sjödén; Arkan S Sayed-Noor
Journal:  Orthop Rev (Pavia)       Date:  2013-06-11

3.  Are abductor muscle quality and previous revision surgery predictors of constrained liner failure in hip arthroplasty?

Authors:  Michael G Zywiel; Loi'y H Mustafa; Peter M Bonutti; Michael A Mont
Journal:  Int Orthop       Date:  2010-02-20       Impact factor: 3.075

4.  Unipolar versus bipolar Exeter hip hemiarthroplasty: a prospective cohort study on 830 consecutive hips in patients with femoral neck fractures.

Authors:  Anders Enocson; Carl Johan Hedbeck; Hans Törnkvist; Jan Tidermark; Lasse J Lapidus
Journal:  Int Orthop       Date:  2011-07-26       Impact factor: 3.075

5.  Low Frequency of Early Complications With Dual-mobility Acetabular Cups in Cementless Primary THA.

Authors:  Morad Chughtai; Jaydev B Mistry; Aloise M Diedrich; Julio J Jauregui; Randa K Elmallah; Peter M Bonutti; Steven F Harwin; Arthur L Malkani; Frank R Kolisek; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

Review 6.  Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options.

Authors:  Luigi Zagra; Eleonora Caboni
Journal:  Int Orthop       Date:  2017-01-14       Impact factor: 3.075

Review 7.  Biomechanical concept and clinical outcome of dual mobility cups.

Authors:  Aron Grazioli; Eugene Teow Hin Ek; Hannes Andreas Rüdiger
Journal:  Int Orthop       Date:  2012-10-17       Impact factor: 3.075

8.  The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies.

Authors:  Matteo Romagnoli; Alberto Grassi; Giuseppe Gianluca Costa; Lionel E Lazaro; Mirco Lo Presti; Stefano Zaffagnini
Journal:  Int Orthop       Date:  2018-07-21       Impact factor: 3.075

9.  Acetabular liner with focal constraint to prevent dislocation after THA.

Authors:  Jacob T Munro; Mihai H Vioreanu; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

10.  High failure rate of the Duraloc Constrained Inlay.

Authors:  Gerold Labek; Erich Brabec; Stephan Frischhut; Martin Krismer
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.