Literature DB >> 31136427

Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?

Adrian Bauze1, Somen Agrawal, Alana Cuthbert, Richard de Steiger.   

Abstract

BACKGROUND: Hooded acetabular liners and head sizes ≥ 32 mm have both shown to have a beneficial effect on the revision rate for dislocation in THA. Experience with noncrosslinked polyethylene (nonXLPE) raised concerns regarding the risk of impingement damage, loosening, and osteolysis with hooded liners; however, the evidence for this in crosslinked polyethylene (XLPE) is inconclusive. The interaction between different femoral head sizes and hooded liners is not well understood, and it is unclear whether hooded XLPE liners have a beneficial effect on overall long-term survivorship. QUESTIONS/PURPOSES: We analyzed a large national joint registry to ask: (1) Is the use of hooded XLPE liners associated with a reduced revision rate for dislocation compared with nonhooded liners? (2) Is there a difference in the revision rate for aseptic loosening/osteolysis? (3) Is head size associated with any difference in the revision rate between hooded and nonhooded liners?
METHODS: The Australian Orthopaedic Association National Joint Replacement Registry longitudinally maintains data on all primary and revision joint arthroplasties with nearly 100% capture. We analyzed all conventional primary THAs performed from registry inception in September 1999 until December 31, 2016 in patients with a diagnosis of osteoarthritis who had nonhooded or hooded XLPE bearings in a cementless acetabular shell. The study group included 192,659 THA procedures with XLPE liners, of which 67,904 were nonhooded and 124,755 were hooded. The mean age of patients receiving nonhooded liners was 70 years (range, 11-100 years); 44% were males. This was similar to the patients with hooded liners, who had a mean age of 70 years (range, 16-100 years); 45% were males. The main outcome measure was the cumulative percent revision at 15 years of the THA using Kaplan-Meier estimates of survivorship. We examined reasons for revision and and performed multivariable analysis to control for the confounding factors of three head size groups (< 32mm, 32mm, and > 32mm) and for the method of femoral fixation.
RESULTS: There was a higher revision rate for dislocation for patients with nonhooded liners at all times to 15 years (HR, 1.31; 95% CI, 1.17-1.47; p < 0.001). There was a higher revision rate for the diagnosis of aseptic loosening/osteolysis with patients with nonhooded liners compared with hooded liners (HR, 1.19; 95% CI, 1.05-1.34; p = 0.006). Head sizes of 32 mm or larger were independently associated with a lower comparative revision rate between hooded and nonhooded liners, but this was not apparent for head sizes smaller than 32 mm. It appeared that the main driver of the finding in larger heads was a reduced dislocation risk with hooded liners for 32 mm heads (HR, 1.50; 95% CI, 1.23-1.80; p < 0.001) and for heads larger than 32 mm (HR, 1.50; 95% CI, 1.20-1.89; p < 0.001).
CONCLUSIONS: Prior research has suggested that hooded acetabular liners may be associated with impingement, loosening, and osteolysis; however, in this large, registry-based report we found that XLPE hooded liners are not associated with an increased revision rate for aseptic loosening/osteolysis. Although there are many potential confounding variables in this registry analysis, if anything, surgeons using larger femoral heads and hooded liners likely did so in patients with a higher perceived dislocation risk. Patients with larger heads and XLPE hooded liners were, however, less likely to experience revision for dislocation. These liners therefore appear reasonable to use in primary THA at the surgeon's discretion. LEVEL OF EVIDENCE: Level III, therapeutic study.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31136427      PMCID: PMC6554106          DOI: 10.1097/CORR.0000000000000710

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  26 in total

1.  The spatial location of impingement in total hip arthroplasty.

Authors:  M Yamaguchi; T Akisue; T W Bauer; Y Hashimoto
Journal:  J Arthroplasty       Date:  2000-04       Impact factor: 4.757

2.  Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus.

Authors:  H C Amstutz; R M Lodwig; D J Schurman; A G Hodgson
Journal:  Clin Orthop Relat Res       Date:  1975-09       Impact factor: 4.176

3.  Effect of elevated-rim acetabular liner and 32-mm femoral head on stability in total hip arthroplasty.

Authors:  Duwairi M Qassem; Karlson B Smith
Journal:  Saudi Med J       Date:  2004-01       Impact factor: 1.484

4.  Impingement of acetabular cups in a hip simulator: comparison of highly cross-linked and conventional polyethylene.

Authors:  Keith G Holley; Bridgette D Furman; Omotunde M Babalola; Joseph D Lipman; Douglas E Padgett; Timothy M Wright
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

5.  Impingement in total hip arthroplasty a study of retrieved acetabular components.

Authors:  Won Yong Shon; Todd Baldini; Margaret G Peterson; Timothy M Wright; Eduardo A Salvati
Journal:  J Arthroplasty       Date:  2005-06       Impact factor: 4.757

6.  Competing events influence estimated survival probability: when is Kaplan-Meier analysis appropriate?

Authors:  David Jean Biau; Aurélien Latouche; Raphaël Porcher
Journal:  Clin Orthop Relat Res       Date:  2007-09       Impact factor: 4.176

7.  Fracture of a cross-linked polyethylene liner due to impingement.

Authors:  Gavan P Duffy; Keith K Wannomae; Shannon L Rowell; Orhun K Muratoglu
Journal:  J Arthroplasty       Date:  2009-01       Impact factor: 4.757

8.  Total hip arthroplasty with the Secur-Fit and Secur-Fit plus femoral stem design a brief follow-up report at 5 to 10 years.

Authors:  Stephen J Incavo; Bruce D Beynnon; Kathryn M Coughlin
Journal:  J Arthroplasty       Date:  2007-11-09       Impact factor: 4.757

9.  Elevated-rim acetabular components. Effect on range of motion and stability in total hip arthroplasty.

Authors:  R J Krushell; D W Burke; W H Harris
Journal:  J Arthroplasty       Date:  1991       Impact factor: 4.757

10.  Independent contribution of elevated-rim acetabular liner and femoral head size to the stability of total hip implants.

Authors:  P G Sultan; V Tan; M Lai; J P Garino
Journal:  J Arthroplasty       Date:  2002-04       Impact factor: 4.757

View more
  4 in total

1.  CORR Insights®: Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?

Authors:  Ola Rolfson
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

2.  Editorial Comment: Selected Papers from the 9th International Congress of Arthroplasty Registries.

Authors:  Ola Rolfson
Journal:  Clin Orthop Relat Res       Date:  2021-10-01       Impact factor: 4.755

3.  Dual mobility versus conventional total hip arthroplasty in femoral neck fractures (DISTINCT): protocol for a registry-nested, open-label, cluster-randomised crossover trial.

Authors:  John E Farey; Tamara Hooper; Tania Alland; Justine M Naylor; Thu-Lan Kelly; Michelle Lorimer; Adriane M Lewin; Margaret Rogers; Chi Kin Law; Jacqueline Close; Steven E Graves; Richard S de Steiger; Peter L Lewis; Sam Adie; Ian A Harris
Journal:  BMJ Open       Date:  2022-09-21       Impact factor: 3.006

4.  Recent update on crosslinked polyethylene in total hip arthroplasty.

Authors:  Jean Langlois; Moussa Hamadouche
Journal:  SICOT J       Date:  2020-05-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.