Literature DB >> 14719571

Multidetector row computed tomography of the aorta and peripheral arteries.

Leo P Lawler1, Elliot K Fishman.   

Abstract

MDCT represents a significant advance on SDCT and the advantages it brings are particularly clear in CTA applications. It allows cost effective assessment of longer segments of vascular territories to be imaged with higher spatial, contrast, and temporal resolution. It has replaced SDCT as the new CT standard and its technical abilities are rapidly approaching the temporal resolution of EBCT. With 3-D post processing tools its main benefit is in imaging studies customized to the patient's pathology, with greater measurement accuracy and reliable longitudinal assessment. MDCTA is increasingly applied not to individual vascular territories but to a complete assessment dictated by the pathology, such as the entire aorta and branch vessels in aneurysm evaluation and the aorta and the coronary arteries in dissection cases or the vascular and non-vascular chest in acute chest pain. Greater accuracy of vessel assessment will lead to a refinement of interventional and surgical techniques for an individual patient and facilitates conservative management of conditions that can be reliably monitored non-invasively and the development of intervention criteria. MDCTA will continue to increase its major role in peripheral vascular evaluation in the future though its reliability in assessing small vessels below the knee and in the foot remains to be conclusively proven to obviate the need for diagnostic catheter angiography.

Entities:  

Mesh:

Year:  2003        PMID: 14719571     DOI: 10.1016/s0733-8651(03)00087-0

Source DB:  PubMed          Journal:  Cardiol Clin        ISSN: 0733-8651            Impact factor:   2.213


  8 in total

1.  [Cardiovascular whole-body MRI: possibilities and limitations in prevention].

Authors:  C U Herborn; F M Vogt; M Goyen; S C Goehde; S G Ruehm; M Forsting
Journal:  Radiologe       Date:  2004-09       Impact factor: 0.635

2.  Prognostic significance of multiple-detector computed tomography in conjunction with TIMI risk score for patients with non-ST elevation acute coronary syndrome.

Authors:  Mayumi Noda; Atsushi Takagi; Ryohei Kuwatsuru; Norio Mitsuhashi; Hiroshi Kasanuki
Journal:  Heart Vessels       Date:  2008-05-17       Impact factor: 2.037

3.  128-slice CT angiography of the aorta without ECG-gating: efficacy of faster gantry rotation time and iterative reconstruction in terms of image quality and radiation dose.

Authors:  Vincenzo Russo; Monica Garattoni; Francesco Buia; Domenico Attinà; Luigi Lovato; Maurizio Zompatori
Journal:  Eur Radiol       Date:  2015-05-24       Impact factor: 5.315

4.  Aortic dissection with extension to a patent ductus arteriosus.

Authors:  Emir Festic; Robert M Steiner; Eileen Spatz
Journal:  Int J Cardiovasc Imaging       Date:  2005-08       Impact factor: 2.357

5.  Peripheral artery stent visualization and in-stent stenosis analysis in 16-row computed tomography: an in-vitro evaluation.

Authors:  Christopher Herzog; Christine Grebe; Andreas Mahnken; Joern O Balzer; Martin G Mack; Stefan Zangos; Hanns Ackermann; Stefan Schaller; Tobias Seifert; Bernd Ohnesorge; Thomas J Vogl
Journal:  Eur Radiol       Date:  2005-07-14       Impact factor: 5.315

Review 6.  Computed Tomography Imaging Findings of Acute Aortic Pathologies.

Authors:  Elif S Duran; Farhan Ahmad; Mohamed Elshikh; Irfan Masood; Cihan Duran
Journal:  Cureus       Date:  2019-08-30

7.  Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases.

Authors:  Mayil S Krishnam; Anderanik Tomasian; Sachin Malik; Vibhas Desphande; Gerhard Laub; Stefan G Ruehm
Journal:  Eur Radiol       Date:  2009-12-16       Impact factor: 5.315

8.  Multidetector-row Computed Tomographic Angiography in the Planning of the Local Perforator Flaps.

Authors:  Pavlo O Badiul; Sergii V Sliesarenko
Journal:  Plast Reconstr Surg Glob Open       Date:  2015-09-22
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.