Literature DB >> 15929675

Response to nocturnal alarms using a real-time glucose sensor.

Bruce Buckingham1, Jen Block, Jonathan Burdick, Andrea Kalajian, Craig Kollman, Michael Choy, Darrell M Wilson, Peter Chase.   

Abstract

BACKGROUND: The objective of this study was to determine how subjects responded to alarms for hypo- and hyperglycemia while they were sleeping. RESEARCH DESIGN AND METHODS: Twenty subjects with type 1 diabetes (4-17 years old) were admitted to a clinical research center for approximately 24 h. Each subject wore two GlucoWatch G2 Biographers (GW2B) (Cygnus, Inc., Redwood City, CA) and was videotaped using an infrared camera from 9 p.m. to 7 a.m. The videotapes were reviewed to determine if the GW2B alarms were audible on the tape and to document the subject's response to the alarms. Because many alarms can occur surrounding a change in blood glucose, GW2B alarm "events" are defined as a one or more alarms separated from previous alarms by more than 30 min.
RESULTS: Downloaded data from the biographers identified 240 individual alarms, 75% of which occurred while the subject was sleeping. Of the 240 alarms 68% were audible on the videotape. Subjects awoke to 29% of individual alarms and to 66% of alarm events. Subjects 4-6 years old responded to 17% of alarms, 7-11 year olds responded to 20% of alarms, adolescents responded to 53% of alarms, and parents responded to 37% of alarms. Subjects awoke to 40% of the first alarm during the night, but to only 28% of subsequent alarms. There were 11 events when the glucose was confirmed to be < or = 70 mg/dL, and in each case the subject was awoken. Fifty-five percent of alarm events occurred when there was no hypo- or hyperglycemia confirmed by a reference glucose value.
CONCLUSIONS: Subjects awoke to 29% of individual alarms and to 66% of alarm events. Subjects awoke during all alarm events when hypoglycemia was confirmed, but there was a high incidence of false alarms.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15929675      PMCID: PMC1482828          DOI: 10.1089/dia.2005.7.440

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  13 in total

1.  Prevention of hypoglycemia using risk assessment with a continuous glucose monitoring system.

Authors:  Carine Choleau; Petr Dokladal; Jean-Claude Klein; W Kenneth Ward; George S Wilson; Gérard Reach
Journal:  Diabetes       Date:  2002-11       Impact factor: 9.461

2.  A multicenter study of the accuracy of the One Touch Ultra home glucose meter in children with type 1 diabetes.

Authors: 
Journal:  Diabetes Technol Ther       Date:  2003       Impact factor: 6.118

3.  Fear of hypoglycemia in the parents of children and adolescents with diabetes: maladaptive or healthy response?

Authors:  D G Marrero; J C Guare; J L Vandagriff; N S Fineberg
Journal:  Diabetes Educ       Date:  1997 May-Jun       Impact factor: 2.140

4.  Use of the GlucoWatch biographer in children with type 1 diabetes.

Authors:  H Peter Chase; Mary D Roberts; Clare Wightman; Georgeanna Klingensmith; Satish K Garg; Michelle Van Wyhe; Shashi Desai; Wesley Harper; Margarita Lopatin; Miroslaw Bartkowiak; Janet Tamada; Richard C Eastman
Journal:  Pediatrics       Date:  2003-04       Impact factor: 7.124

5.  Dead-in-bed syndrome in young diabetic patients.

Authors:  O Sovik; H Thordarson
Journal:  Diabetes Care       Date:  1999-03       Impact factor: 19.112

6.  Evaluation and comparison of 10 glucose methods and the reference method recommended in the proposed product class standard (1974).

Authors:  R B Passey; R L Gillum; J B Fuller; F M Urry; M L Giles
Journal:  Clin Chem       Date:  1977-01       Impact factor: 8.327

Review 7.  Glucose monitoring by reverse iontophoresis.

Authors:  Russell O Potts; Janet A Tamada; Michael J Tierney
Journal:  Diabetes Metab Res Rev       Date:  2002 Jan-Feb       Impact factor: 4.876

8.  Hypoglycemia: incidence and clinical predictors in a large population-based sample of children and adolescents with IDDM.

Authors:  E A Davis; B Keating; G C Byrne; M Russell; T W Jones
Journal:  Diabetes Care       Date:  1997-01       Impact factor: 19.112

9.  Use of the Cygnus GlucoWatch biographer at a diabetes camp.

Authors:  Laura M Gandrud; Helen U Paguntalan; M Michelle Van Wyhe; Betsy L Kunselman; Amy D Leptien; Darrell M Wilson; Richard C Eastman; Bruce A Buckingham
Journal:  Pediatrics       Date:  2004-01       Impact factor: 7.124

10.  Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia: experience of the Diabetes Research in Children Network.

Authors: 
Journal:  Diabetes Care       Date:  2004-03       Impact factor: 19.112

View more
  41 in total

1.  Alarm characterization for a continuous glucose monitor that replaces traditional blood glucose monitoring.

Authors:  Geoffrey McGarraugh
Journal:  J Diabetes Sci Technol       Date:  2010-01-01

2.  Alarm characterization for continuous glucose monitors used as adjuncts to self-monitoring of blood glucose.

Authors:  Geoffrey McGarraugh
Journal:  J Diabetes Sci Technol       Date:  2010-01-01

3.  Effect of short-term use of a continuous glucose monitoring system with a real-time glucose display and a low glucose alarm on incidence and duration of hypoglycemia in a home setting in type 1 diabetes mellitus.

Authors:  Raymond J Davey; Timothy W Jones; Paul A Fournier
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

Review 4.  Toward closing the loop: an update on insulin pumps and continuous glucose monitoring systems.

Authors:  Tandy Aye; Jen Block; Bruce Buckingham
Journal:  Endocrinol Metab Clin North Am       Date:  2010-09       Impact factor: 4.741

5.  Clinical overview of continuous glucose monitoring.

Authors:  Bruce Buckingham
Journal:  J Diabetes Sci Technol       Date:  2008-03

6.  Outcome measures for outpatient hypoglycemia prevention studies.

Authors:  Roy W Beck; Craig Kollman; Dongyuan Xing; Bruce A Buckingham; H Peter Chase
Journal:  J Diabetes Sci Technol       Date:  2011-07-01

7.  Inpatient studies of a Kalman-filter-based predictive pump shutoff algorithm.

Authors:  Fraser Cameron; Darrell M Wilson; Bruce A Buckingham; Hasmik Arzumanyan; Paula Clinton; H Peter Chase; John Lum; David M Maahs; Peter M Calhoun; B Wayne Bequette
Journal:  J Diabetes Sci Technol       Date:  2012-09-01

8.  Real-Time hypoglycemia prediction suite using continuous glucose monitoring: a safety net for the artificial pancreas.

Authors:  Eyal Dassau; Fraser Cameron; Hyunjin Lee; B Wayne Bequette; Howard Zisser; Lois Jovanovic; H Peter Chase; Darrell M Wilson; Bruce A Buckingham; Francis J Doyle
Journal:  Diabetes Care       Date:  2010-06       Impact factor: 17.152

9.  Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring.

Authors:  Tai-Ping Sun; Hsiu-Li Shieh; Congo Tak-Shing Ching; Yan-Dong Yao; Su-Hua Huang; Chia-Ming Liu; Wei-Hao Liu; Chung-Yuan Chen
Journal:  Int J Nanomedicine       Date:  2010-05-13

10.  Prevention of nocturnal hypoglycemia using predictive alarm algorithms and insulin pump suspension.

Authors:  Bruce Buckingham; H Peter Chase; Eyal Dassau; Erin Cobry; Paula Clinton; Victoria Gage; Kimberly Caswell; John Wilkinson; Fraser Cameron; Hyunjin Lee; B Wayne Bequette; Francis J Doyle
Journal:  Diabetes Care       Date:  2010-03-03       Impact factor: 19.112

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.