Use of the GlucoWatch biographer in children with type 1 diabetes.

H Peter Chase1, Mary D Roberts, Clare Wightman, Georgeanna Klingensmith, Satish K Garg, Michelle Van Wyhe, Shashi Desai, Wesley Harper, Margarita Lopatin, Miroslaw Bartkowiak, Janet Tamada, Richard C Eastman.   

Abstract

OBJECTIVE: To determine whether use of the GlucoWatch biographer improves glucose control in children and adolescents with type 1 diabetes.
METHODS: Forty children in poor glucose control (glycohemoglobin [HbA1c] >8%) were randomized to diabetes management with or without glucose monitoring using the biographer. Conventional glucose monitoring was performed 4 times daily in both groups. Those randomized to the biographer group were asked to wear the device 4 times per week for 3 months (intervention phase) and to perform blood glucose monitoring if the biographer alerted them that glucose was < or =70 mg/dL (3.9 mmol/L) or > or =300 mg/dL (16.7 mmol/L). After 3 months, all patients received biographers and were followed for 6 months (observation phase). HbA1c values were determined at baseline and after 1, 3, 6, and 9 months.
RESULTS: The median HbA1c was 8.6% and 8.9% (control versus biographer) at baseline and was significantly lower in the biographer group after 3 months (8.4% vs 9%). More hypoglycemia was detected when subjects were wearing the biographer, especially at night. No severe hypoglycemia occurred. During the observation phase, HbA1c values at 6 months were 8.5% and 8.3% and at 9 months were 8.6% and 8.4% in the control and biographer groups, respectively. Two children dropped out of the study, 1 because of skin irritation from using the device.
CONCLUSIONS: The GlucoWatch biographer was well tolerated by children and adolescents and significantly improved glucose control compared with standard therapy. The use of the biographer with an alarm to detect nocturnal hypoglycemia has the potential to increase the safety of diabetes management in children.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12671113     DOI: 10.1542/peds.111.4.790

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  20 in total

Review 1.  Evolving approaches to intensive insulin therapy in type 1 diabetes: multiple daily injections, insulin pumps and new methods of monitoring.

Authors:  Elizabeth Stephens; Matthew Riddle
Journal:  Rev Endocr Metab Disord       Date:  2003-12       Impact factor: 6.514

2.  Effect of short-term use of a continuous glucose monitoring system with a real-time glucose display and a low glucose alarm on incidence and duration of hypoglycemia in a home setting in type 1 diabetes mellitus.

Authors:  Raymond J Davey; Timothy W Jones; Paul A Fournier
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

3.  Response to nocturnal alarms using a real-time glucose sensor.

Authors:  Bruce Buckingham; Jen Block; Jonathan Burdick; Andrea Kalajian; Craig Kollman; Michael Choy; Darrell M Wilson; Peter Chase
Journal:  Diabetes Technol Ther       Date:  2005-06       Impact factor: 6.118

4.  Youth and parent satisfaction with clinical use of the GlucoWatch G2 Biographer in the management of pediatric type 1 diabetes.

Authors: 
Journal:  Diabetes Care       Date:  2005-08       Impact factor: 19.112

5.  No effect of periodic continuous glucose monitoring on hemoglobin A1c in poorly regulated type 1 patients.

Authors:  Henrik U Andersen; Majbritt Kjelmann; Minna Wittrup; Thomas P Almdal
Journal:  J Diabetes Sci Technol       Date:  2013-05-01

Review 6.  Efficacy of continuous glucose monitoring in improving glycemic control and reducing hypoglycemia: a systematic review and meta-analysis of randomized trials.

Authors:  Gunjan Y Gandhi; Michelle Kovalaske; Yogish Kudva; Kristin Walsh; Mohamed B Elamin; Melody Beers; Cathy Coyle; Melissa Goalen; Mohammad Safwan Murad; Patricia J Erwin; Joshua Corpus; Victor M Montori; M Hassan Murad
Journal:  J Diabetes Sci Technol       Date:  2011-07-01

7.  Accuracy of the SEVEN continuous glucose monitoring system: comparison with frequently sampled venous glucose measurements.

Authors:  Howard C Zisser; Timothy S Bailey; Sherwyn Schwartz; Robert E Ratner; Jonathan Wise
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

8.  A review of current evidence with continuous glucose monitoring in patients with diabetes.

Authors:  Christophe De Block; Begoña Manuel-y-Keenoy; Luc Van Gaal
Journal:  J Diabetes Sci Technol       Date:  2008-07

9.  Psychological aspects of continuous glucose monitoring in pediatric type 1 diabetes.

Authors: 
Journal:  Pediatr Diabetes       Date:  2006-02       Impact factor: 4.866

10.  The accuracy of the GlucoWatch G2 biographer in children with type 1 diabetes: results of the diabetes research in children network (DirecNet) accuracy study.

Authors: 
Journal:  Diabetes Technol Ther       Date:  2003       Impact factor: 6.118

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.